{"title":"Cable Number 3 - High-Pressure Oil-Filled Self-Contained Type","authors":"E. Merrell, A. Mckean","doi":"10.1109/AIEEPAS.1962.4501363","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501363","url":null,"abstract":"","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125368948","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Cornell EHV Cable Testing Station-Equipment an Design","authors":"A. D. Bertolett, C. S. Schifreen","doi":"10.1109/AIEEPAS.1962.4501356","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501356","url":null,"abstract":"","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"306 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116116384","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Assembled Switchgear Designed by Computer I-Design to Application Specification","authors":"H. B. Wortman, M. H. Waller","doi":"10.1109/AIEEPAS.1962.4501422","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501422","url":null,"abstract":"Assembled switchgear customer-order development begins when the application is expressed in fundamental electrical units and the arrangement is defined. The basic description is then interpreted in manufacturing part numbers, and displayed on traditional requisition and drawing format. A computer program has been applied to this conversion for metalclad switchgear. In effect, designers are provided with a mechanized catalog-searching facility, and are relieved of some of the drafting, a handicraft wasteful in its consumption of creative hours.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116500795","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Short-Circiut Testing of Distribution Transformers","authors":"M. F. Beavers, C. M. Adams, J. Holcomb","doi":"10.1109/AIEEPAS.1962.4501387","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501387","url":null,"abstract":"This paper presents a discussion of the current and voltage relationship during a short-circuit on a distribution transformer. It shows the relative effect on the magnitude of the offset current when the short circuit occurs at various times with respect to the voltage zero and the effect of self-heating of the transformer on the resulting short-circuit current. It also presents recommendations for consideration in a short-circuit test code for distribution transformers only.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134290119","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A 2-Cycle 138-Kv 10,000,000-Kva Air-Blast Circuit Breaker Design Considerations and Field Tests at Philip Sporn Station","authors":"O. Naef, J. Beehler, R. B. Shores, J. W. Beatty","doi":"10.1109/AIEEPAS.1962.4501426","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501426","url":null,"abstract":"A 2-cycle 138-kv 10,000-mva (megavolt-ampere) air-blast circuit breaker has been developed and field tested. Insofar as is known, this is the first 2-cycle breaker for transmission line voltages. The breaker interrupted both transmission line and bus faults while mounted on the trailer on which it was shipped. The maximum breaker duty was 10,230 mva. It is believed this is the highest fault duty ever imposed on a 138-kv breaker in a field test. The longest interrupting time was 1.85 cycles. The breaker rating is based on the proposed, symmetrical rating structure.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"112 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134427554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Review of the High-Voltage Cable Testing Conditions and Results at the Electricité de France Fontenay Station","authors":"R. Tellier","doi":"10.1109/AIEEPAS.1962.4501353","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501353","url":null,"abstract":"","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130367333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Surge Performance of Cable-Connected Pad-Mounted Distribution Transformers","authors":"H. R. Armstrong, M. Charneski, R. T. Curto","doi":"10.1109/AIEEPAS.1962.4501401","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501401","url":null,"abstract":"The lightning protection of pad-mounted distribution transformers supplied through buried cable from open-wire circuits was investigated in the laboratory. Several distribution transformers and field lengths of equivalent cable were connected to form a typical underground distribution layout of limited size. Cost and space limitations in providing valve-type arresters at each transformer place emphasis on obtaining over-all protection from only the cable-open wire-junction arresters. The influence of wave shape, cable length and characteristics, and the relation of the transformer basic impulse insulation level (BIL) were considered.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114114290","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transformer Circuits for Digital Studies","authors":"R. B. Shipley, D. Coleman, C. Watts","doi":"10.1109/AIEEPAS.1962.4501482","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501482","url":null,"abstract":"A new method for calculating the equivalent circuit of multiwinding transformers is presented. The method is especially suitable for computer work. The equivalenst circuit includes the effect of transformer taps, bult ignores magnetizing current. The number of junction points and the number of Impedances required for the equivalent circuit are minimized. Thus, the high-speed memory requirements of the digital computer are minimized. The per-cent impedance is assumed independent of the transformer tap setting.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123411907","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"New Method for Locating Transmission Line Ground Faults","authors":"M. J. Lantz","doi":"10.1109/AIEEPAS.1962.4501284","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501284","url":null,"abstract":"The current ratio method has yielded good results for ground fault location, however, it is dependent on current readings from both ends of a 2-terminal transmission line. The proposed method is operable from current data, namely, the phase and residual currents, from a single terminal. A distinctive ratio curve is obtained for circuits containing series capacitors, and the method provides a means for locating ground faults on 3-terminal circuits.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125536841","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Considerations in Establishing Standard of Meckanical Loads on Oil-Circuit-Breaker Bushings","authors":"W. E. Harper, E. Huston","doi":"10.1109/AIEEPAS.1962.4501381","DOIUrl":"https://doi.org/10.1109/AIEEPAS.1962.4501381","url":null,"abstract":"The present bushing standards which cover electrical and major dimensional requirements provide a considerable degree of interchangeability. A standard of mechanical bushing load requirements is needed for oil-circuit-breaker applications. A standard of static loads has been proposed. This paper deals with an extension of this proposal and offers considerations for establishing adynamic loading standard. It also presents a method of producing, by the use of explosive charges, dynamic forces similar to those recorded under actual interrupting conditions.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"149 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116525272","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}