{"title":"电缆连接垫式配电变压器的浪涌性能","authors":"H. R. Armstrong, M. Charneski, R. T. Curto","doi":"10.1109/AIEEPAS.1962.4501401","DOIUrl":null,"url":null,"abstract":"The lightning protection of pad-mounted distribution transformers supplied through buried cable from open-wire circuits was investigated in the laboratory. Several distribution transformers and field lengths of equivalent cable were connected to form a typical underground distribution layout of limited size. Cost and space limitations in providing valve-type arresters at each transformer place emphasis on obtaining over-all protection from only the cable-open wire-junction arresters. The influence of wave shape, cable length and characteristics, and the relation of the transformer basic impulse insulation level (BIL) were considered.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The Surge Performance of Cable-Connected Pad-Mounted Distribution Transformers\",\"authors\":\"H. R. Armstrong, M. Charneski, R. T. Curto\",\"doi\":\"10.1109/AIEEPAS.1962.4501401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The lightning protection of pad-mounted distribution transformers supplied through buried cable from open-wire circuits was investigated in the laboratory. Several distribution transformers and field lengths of equivalent cable were connected to form a typical underground distribution layout of limited size. Cost and space limitations in providing valve-type arresters at each transformer place emphasis on obtaining over-all protection from only the cable-open wire-junction arresters. The influence of wave shape, cable length and characteristics, and the relation of the transformer basic impulse insulation level (BIL) were considered.\",\"PeriodicalId\":118797,\"journal\":{\"name\":\"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1962-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AIEEPAS.1962.4501401\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AIEEPAS.1962.4501401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Surge Performance of Cable-Connected Pad-Mounted Distribution Transformers
The lightning protection of pad-mounted distribution transformers supplied through buried cable from open-wire circuits was investigated in the laboratory. Several distribution transformers and field lengths of equivalent cable were connected to form a typical underground distribution layout of limited size. Cost and space limitations in providing valve-type arresters at each transformer place emphasis on obtaining over-all protection from only the cable-open wire-junction arresters. The influence of wave shape, cable length and characteristics, and the relation of the transformer basic impulse insulation level (BIL) were considered.