Nuclear Instruments and Methods in Physics Research最新文献

筛选
英文 中文
The source for negative sodium ions at the Heidelberg MP-tandem accelerator 海德堡mp串联加速器中负钠离子的来源
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90265-5
K.-H. Möbius, K. Blatt
{"title":"The source for negative sodium ions at the Heidelberg MP-tandem accelerator","authors":"K.-H. Möbius,&nbsp;K. Blatt","doi":"10.1016/0167-5087(84)90265-5","DOIUrl":"10.1016/0167-5087(84)90265-5","url":null,"abstract":"<div><p>A source for <sup>23</sup>Na<sup>−</sup> ions is described. A thermal atomic <sup>23</sup>Na beam is ionized on a W-O surface. By use of charge exchange in Cs vapour beam currents up to 500 nA of <sup>23</sup>Na<sup>−</sup> ions were injected into the Heidelberg MP-tandem accelerator.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 293-297"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90265-5","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74855108","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A lightweight shield-detector combination for use in hard X-ray telescopes 用于硬x射线望远镜的轻型屏蔽探测器组合
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90281-3
H. Griffiths , R.R. Hillier
{"title":"A lightweight shield-detector combination for use in hard X-ray telescopes","authors":"H. Griffiths ,&nbsp;R.R. Hillier","doi":"10.1016/0167-5087(84)90281-3","DOIUrl":"10.1016/0167-5087(84)90281-3","url":null,"abstract":"<div><p>By coupling a simple, passive shield of tin with a thin NaI (Tl) detector the atmospheric background counting rate in the energy range 15–95 keV can be attenuated by a factor of approximately 12.5. Including the weight of the collimator, a telescope built with this combination would have a total surface density of only ∼ 3 g cm<sup>−2</sup>, allowing a sensitive area of ∼ 30 m<sup>2</sup> to be constructed within the normal restrictions of weight on a balloon experiment. To measure the of effectiveness of different types of shielding, the atmospheric gamma radiation was simulated using a tank of water containing radioactive sources.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 418-421"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90281-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77913908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Laser induced ionisation in proportional counters seeded with low ionisation potential vapours 激光诱导电离在比例计数器播种低电离势蒸汽
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90269-2
K.W.D. Ledingham, C. Raine, K.M. Smith, A.M. Campbell, M. Towrie, C. Trager , C.M. Houston
{"title":"Laser induced ionisation in proportional counters seeded with low ionisation potential vapours","authors":"K.W.D. Ledingham,&nbsp;C. Raine,&nbsp;K.M. Smith,&nbsp;A.M. Campbell,&nbsp;M. Towrie,&nbsp;C. Trager ,&nbsp;C.M. Houston","doi":"10.1016/0167-5087(84)90269-2","DOIUrl":"10.1016/0167-5087(84)90269-2","url":null,"abstract":"<div><p>Four vapours with low ionisation potentials: triethylamine (TEA), N,N-dimethylaniline (DMA), N,N-diethylaniline (DEA) and tetrakis (dimethylamino) ethylene (TMAEO) have been studied to produce controlled amounts of laser induced ionisation in proportional counters. DMA, DEA, and TMAE produce large amounts of ionisation at the nitrogen lase wavelength (337 nm) but TMAE has proved difficult to control. At 337 nm TEA does not ionise significantly but initial tests show that it also becomes suitable as a seeding agent at shorter wavelengths.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 319-324"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90269-2","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84439041","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Spherical positron emission tomograph (S-PET) I - performance analysis 球面正电子发射层析成像(S-PET) I -性能分析
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90282-5
Z.H. Cho , K.S. Hong, S.K. Hilal
{"title":"Spherical positron emission tomograph (S-PET) I - performance analysis","authors":"Z.H. Cho ,&nbsp;K.S. Hong,&nbsp;S.K. Hilal","doi":"10.1016/0167-5087(84)90282-5","DOIUrl":"10.1016/0167-5087(84)90282-5","url":null,"abstract":"<div><p>A spherical positron emission tomograph (S-PET) is proposed and its performance analyzed. Computer modelling and simulation studies indicate that a high resolution and high sensitivity positron emission tomograph having a spatial resolution of 2–3 mm fwhm can be realized with acceptable imaging time and sensitivity.</p><p>Multilayer S-PET having 16–24 layers is specifically analyzed and compared with its corresponding cylindrical counterpart. The result shows that the sensitivity gain of the spherical system is a factor 3 over the cylindrical system with identical true to scatter and random ratios.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 422-438"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90282-5","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81031110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 22
Performance of the silica aerogel cherenkov detector used in the European hybrid spectrometer 欧洲混合光谱仪中二氧化硅气凝胶切伦科夫检测器的性能
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90268-0
C. Fernandez, K.E. Johansson, M. Schouten, S. Tavernier, P. Ladron de Guevara, P. Herquet, J. Kesteman, O. Pingot
{"title":"Performance of the silica aerogel cherenkov detector used in the European hybrid spectrometer","authors":"C. Fernandez,&nbsp;K.E. Johansson,&nbsp;M. Schouten,&nbsp;S. Tavernier,&nbsp;P. Ladron de Guevara,&nbsp;P. Herquet,&nbsp;J. Kesteman,&nbsp;O. Pingot","doi":"10.1016/0167-5087(84)90268-0","DOIUrl":"10.1016/0167-5087(84)90268-0","url":null,"abstract":"<div><p>The performance of an 18 module silica aerogel Cherenkov detector, with a total sensitive surface of 2.3 m<sup>2</sup>, situated in the European Hybrid Spectrometer at the CERN SPS, is described. The light yield for <em>β</em> = 1 particles is on the average 7.5±0.3 photoelectrons. Particle identification with this detector is discussed. Fi3st results on the ageing effects of silica aerogel are presented.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 313-318"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90268-0","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85382421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
A microprogrammable high-speed data collection system for position sensitive x-ray detectors 一种用于位置敏感x射线探测器的微可编程高速数据采集系统
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90272-2
H. Hashizume, Y. Iitaka, T. Ogawa
{"title":"A microprogrammable high-speed data collection system for position sensitive x-ray detectors","authors":"H. Hashizume,&nbsp;Y. Iitaka,&nbsp;T. Ogawa","doi":"10.1016/0167-5087(84)90272-2","DOIUrl":"10.1016/0167-5087(84)90272-2","url":null,"abstract":"<div><p>A high-speed data acquisition system has been designed which collect digital data from one- and two-dimensional position sensitive X-ray detectors at a maximum average data rate of 1 MHz. The system consists of two separate fast buffer memories, a 64K word by 20-bit main storage, two timers, a display controller, a computer interface and a keyboard, controlled by a specially designed microprogrammable microprocessor. Data collection is performed by executing a microprogram stored in the control storage; data coming from a detector are first accumulated in a small but fast buffer memory by hardware and transferred to the main storage under control of the microprogram. This design not only permits time-resolved data collections but also provides maximum speed, flexibility and cost-effectiveness simultaneously. The system also accepts data from integrating detectors such as TV cameras. The system has been designed for use in experiments at conventional and synchrotron X-ray sources.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 335-346"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90272-2","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84121051","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thoron daughter working level measurements by one and two gross alpha-count methods 用一种和两种总α计数法测量梭隆子工作水平
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90277-1
J. Bigu, M. Grenier
{"title":"Thoron daughter working level measurements by one and two gross alpha-count methods","authors":"J. Bigu,&nbsp;M. Grenier","doi":"10.1016/0167-5087(84)90277-1","DOIUrl":"10.1016/0167-5087(84)90277-1","url":null,"abstract":"<div><p>A study has been conducted on the determination of the thoron daughter working level, WL(Tn), by one gross α-count, and of WL(Tn) and the concentrations of ThB, [ThB], and ThC, [ThC], by two gross α-counts. For the one gross α-count the relationship between the gross α-count rate per unit of volume of air sampled and WL(Tn), denoted the <em>F</em>-factor, has been investigated as a function of sampling time, elapsed time from the end of the sampling period, i.e., waiting time, and the thoron daughter disequilibrium ratio [ThC]/[ThB]. It has been found that <em>F</em> depends on both the waiting time and [ThC]/[ThB]. If α-count measurements are made at least 300 minutes after the end of sampling, <em>F</em> changes by less than 10% over the full range of theoretical values of [ThC]/[ThB], i.e., from 0 to 1. The <em>F</em>-factor is independent of [ThC]/[ThB] at approximately 215 min after the end of sampling. This feature can be used to determine WL(Tn) with higher accuracy and at least 1.5 h earlier than is commonly done using other one gross α-count methods reported in the literature. An optimization method based on standard statistical techniques has been followed for the two gross α-count method. Optimum combinations of sampling, waiting and counting times compatible with experimental constraints have been obtained. A sampling time of 10 min and equal counting times of 15 min for the first and second α-counts situated 2 min and 92 min, respectively, after the end of sampling have been used in conjunction with a thoron daughter calibration facility. Comparison of the two gross α-counts method investigated here with other methods shows excellent agreement.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 385-398"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90277-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84641396","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Time resolving bent crystal spectrometer for tokamak plasma diagnostics 用于托卡马克等离子体诊断的时间分辨弯曲晶体光谱仪
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90276-X
R. Bartiromo, R. Giannella, M.L. Apicella, F. Bombarda, S. Mantovani, G. Pizzicaroli
{"title":"Time resolving bent crystal spectrometer for tokamak plasma diagnostics","authors":"R. Bartiromo,&nbsp;R. Giannella,&nbsp;M.L. Apicella,&nbsp;F. Bombarda,&nbsp;S. Mantovani,&nbsp;G. Pizzicaroli","doi":"10.1016/0167-5087(84)90276-X","DOIUrl":"10.1016/0167-5087(84)90276-X","url":null,"abstract":"<div><p>A high-throughput high-resolution curved crystal spectrometer for measurements in the soft X-ray range on fusion magnetic devices is described. The spectrometer uses a large useful area (8 × 5 cm<sup>2</sup>) quartz lamina bent at a curvature radius 385 cm long as the dispersing element. The detector is a one-dimensional space resolving multiwire proportional counter. The spectral resolving power is <em>R</em> = 18 000, permitting to obtain adequate ion temperature measurements, down to 700 eV, from the Doppler broadening of resonance lines of highly ionized metallic impurities.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 378-384"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90276-X","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89540551","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
Study of event mixing and its application to the extraction of resonance signals 事件混合及其在共振信号提取中的应用研究
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90275-8
D. Drijard, H.G. Fischer, T. Nakada
{"title":"Study of event mixing and its application to the extraction of resonance signals","authors":"D. Drijard,&nbsp;H.G. Fischer,&nbsp;T. Nakada","doi":"10.1016/0167-5087(84)90275-8","DOIUrl":"10.1016/0167-5087(84)90275-8","url":null,"abstract":"<div><p>The features of the invariant mass distribution obtained from combinations of particles from different events, i.e. event mixing, is studied in detail. It is shown that special care is needed in order to reproduce the shape of the uncorrelated invariant mass distribution. A way to determine the number of resonances and its statistical error using an event mixing technique is described.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 367-377"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90275-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77417483","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 50
The performance of a prototype precision drift chamber for colliding beam experiments 碰撞光束精密漂移室实验样机的性能
Nuclear Instruments and Methods in Physics Research Pub Date : 1984-08-15 DOI: 10.1016/0167-5087(84)90267-9
A.A. Carter , J.R. Carter , G. Ero , M.J. Goodrick , T.W. Pritchard
{"title":"The performance of a prototype precision drift chamber for colliding beam experiments","authors":"A.A. Carter ,&nbsp;J.R. Carter ,&nbsp;G. Ero ,&nbsp;M.J. Goodrick ,&nbsp;T.W. Pritchard","doi":"10.1016/0167-5087(84)90267-9","DOIUrl":"10.1016/0167-5087(84)90267-9","url":null,"abstract":"<div><p>We review the characteristics of compact precise drift chambers and present the essential features of a vertex detector for an experiment at LEP. We discuss the initial performance of a prototype chamber and illustrate its good two-particle resolution.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 308-312"},"PeriodicalIF":0.0,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90267-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87281690","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信