{"title":"海德堡mp串联加速器中负钠离子的来源","authors":"K.-H. Möbius, K. Blatt","doi":"10.1016/0167-5087(84)90265-5","DOIUrl":null,"url":null,"abstract":"<div><p>A source for <sup>23</sup>Na<sup>−</sup> ions is described. A thermal atomic <sup>23</sup>Na beam is ionized on a W-O surface. By use of charge exchange in Cs vapour beam currents up to 500 nA of <sup>23</sup>Na<sup>−</sup> ions were injected into the Heidelberg MP-tandem accelerator.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 293-297"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90265-5","citationCount":"3","resultStr":"{\"title\":\"The source for negative sodium ions at the Heidelberg MP-tandem accelerator\",\"authors\":\"K.-H. Möbius, K. Blatt\",\"doi\":\"10.1016/0167-5087(84)90265-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A source for <sup>23</sup>Na<sup>−</sup> ions is described. A thermal atomic <sup>23</sup>Na beam is ionized on a W-O surface. By use of charge exchange in Cs vapour beam currents up to 500 nA of <sup>23</sup>Na<sup>−</sup> ions were injected into the Heidelberg MP-tandem accelerator.</p></div>\",\"PeriodicalId\":100972,\"journal\":{\"name\":\"Nuclear Instruments and Methods in Physics Research\",\"volume\":\"225 2\",\"pages\":\"Pages 293-297\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0167-5087(84)90265-5\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods in Physics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0167508784902655\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167508784902655","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The source for negative sodium ions at the Heidelberg MP-tandem accelerator
A source for 23Na− ions is described. A thermal atomic 23Na beam is ionized on a W-O surface. By use of charge exchange in Cs vapour beam currents up to 500 nA of 23Na− ions were injected into the Heidelberg MP-tandem accelerator.