Nuclear Instruments最新文献

筛选
英文 中文
Thin carbon films for use with electrostatic accelerators 与静电加速器配套使用的碳薄膜
Nuclear Instruments Pub Date : 1958-05-01 DOI: 10.1016/0369-643X(58)90120-8
N. Sarma
{"title":"Thin carbon films for use with electrostatic accelerators","authors":"N. Sarma","doi":"10.1016/0369-643X(58)90120-8","DOIUrl":"10.1016/0369-643X(58)90120-8","url":null,"abstract":"","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 4","pages":"Pages 361-362"},"PeriodicalIF":0.0,"publicationDate":"1958-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90120-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81943133","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Pulsed high-intensity ion source 脉冲高强度离子源
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90034-3
Rolf Pauli, Jan Flinta
{"title":"Pulsed high-intensity ion source","authors":"Rolf Pauli, Jan Flinta","doi":"10.1016/0369-643X(58)90034-3","DOIUrl":"https://doi.org/10.1016/0369-643X(58)90034-3","url":null,"abstract":"","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 227-236"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90034-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136902153","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Pulsed beam deflection system for a linear electron accelerator 用于直线电子加速器的脉冲束偏转系统
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90040-9
M.J. Poole, G. Dean, W. Howe
{"title":"Pulsed beam deflection system for a linear electron accelerator","authors":"M.J. Poole,&nbsp;G. Dean,&nbsp;W. Howe","doi":"10.1016/0369-643X(58)90040-9","DOIUrl":"10.1016/0369-643X(58)90040-9","url":null,"abstract":"<div><p>A method has been developed to permit the simultaneous use of two targets with a pulsed linear electron accelerator. A magnet is arranged to deflect the beam onto one or the other target, and this magnet is electronically switched on or off in the interval between the beam pulses. A“ccount-down” circuit is used to select which pulses shall be directed to each target.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 282-286"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90040-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86687705","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electromagnetic isotope separator in Gothenburg 哥德堡的电磁同位素分离器
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90036-7
O. Almén, G. Bruce, A. Lundén
{"title":"Electromagnetic isotope separator in Gothenburg","authors":"O. Almén,&nbsp;G. Bruce,&nbsp;A. Lundén","doi":"10.1016/0369-643X(58)90036-7","DOIUrl":"10.1016/0369-643X(58)90036-7","url":null,"abstract":"<div><p>A 90° electromagnetic isotope separator with a beam radius of 100 cm is described. Using an acceleration voltage of 50 kV, ion currents of up to a few hundred μA can be handled. The ion current and resolving power can be varied within wide limits by adjusting the position of the lens system during operation. Two types of magnetic ion sources have been used to prepare targets for nuclear reaction studies and samples for beta- and gamma-ray spectroscopy.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 249-250"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90036-7","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75411056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 23
On the pulse shape in a cylindrical ionization chamber 关于圆柱形电离室中脉冲的形状
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90037-9
C. Cernigoi , G. Pauli , C. Poiani
{"title":"On the pulse shape in a cylindrical ionization chamber","authors":"C. Cernigoi ,&nbsp;G. Pauli ,&nbsp;C. Poiani","doi":"10.1016/0369-643X(58)90037-9","DOIUrl":"10.1016/0369-643X(58)90037-9","url":null,"abstract":"<div><p>The fast ionization chamber, 60 l in volume, filled with argon at 10 atm, is described. The pulse shapes are calculated assuming the ionization: (a) confined to an infinitesimal volume of the chamber, (b) distributed along a straight line parallel to the axis of the chamber, (c) distributed along a straight line passing through the axis of the chamber and perpendicular to it, (d) distributed along a straight line perpendicular to the axis of the chamber and not passing through it, (e) distributed throughout the volume of the chamber.</p><p>A comparison is made between the theoretical pulse shapes and the experimental ones.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 261-269"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90037-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73286764","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Pulsed high-intensity ion source: Part I☆ 脉冲高强度离子源:第一部分☆
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90033-1
J. Flinta
{"title":"Pulsed high-intensity ion source: Part I☆","authors":"J. Flinta","doi":"10.1016/0369-643X(58)90033-1","DOIUrl":"https://doi.org/10.1016/0369-643X(58)90033-1","url":null,"abstract":"","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"23 1","pages":"219-226"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76946806","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Automatic-recording apparatus for fission-fragment time-of-flight measurements 裂变碎片飞行时间测量的自动记录装置
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90039-2
J.S. Fraser, J.C.D. Milton
{"title":"Automatic-recording apparatus for fission-fragment time-of-flight measurements","authors":"J.S. Fraser,&nbsp;J.C.D. Milton","doi":"10.1016/0369-643X(58)90039-2","DOIUrl":"10.1016/0369-643X(58)90039-2","url":null,"abstract":"<div><p>An apparatus has been constructed to measure the velocities of both members of a fission-fragment pair. A zero-time signal is obtained at the expense of about one per cent of the fragment energy by detecting delta rays ejected by the fragment from a thin plastic foil placed near the source. The fragment times of flight are converted to pulse heights for analysis. An overall time resolution of 3.5 mμsec is obtained. A third variable, e.g. gamma-ray energy or prompt neutron time of flight, may also be recorded, the three pulse heights being punched consecutively on paper tape. Three-dimensional analysis is therefore possible but in practice sorting is done taking two variables at a time.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 275-281"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90039-2","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84281495","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Use of Li6I(Eu) as a scintillation detector and spectrometer for fast neutrons 用Li6I(Eu)作为快中子的闪烁探测器和光谱仪
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90035-5
R.B. Murray
{"title":"Use of Li6I(Eu) as a scintillation detector and spectrometer for fast neutrons","authors":"R.B. Murray","doi":"10.1016/0369-643X(58)90035-5","DOIUrl":"10.1016/0369-643X(58)90035-5","url":null,"abstract":"<div><p>The scintillation response of europium activated crystals of Li<sup>6</sup>I to neutrons in the energy range 1–14MeV has been investigated with the crystals maintained at various temperatures. The pulse-height spectrum from mono-energetic neutrons incident on a crystal at room temperature demonstrates a poorly defined and broad fast-neutron peak. Upon cooling the crystal, the fast-neutron peak becomes sharper and assumes a nearly Gaussian shape at temperatures below about — 140° C. This behaviour is attributed to an increased scintillation efficiency of LiI(Eu) to alpha particles at low temperatures. Pulse-height spectra from crystals at the liquid nitrogen point are presented for neutrons from the D(d,n)He<sup>3</sup>, T(d,n)He<sup>4</sup>, and Be<sup>9</sup>(d,n)B<sup>10</sup> reactions, a Po-Be source, and U<sup>235</sup> fission. The principal features of Li<sup>6</sup>I(Eu) as a fast-neutron spectrometer are a relatively high detection efficiency (≈0.1%) and moderate resolution.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 237-248"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90035-5","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83189612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 73
Apparatus for processing nuclear emulsions 核乳剂处理装置
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90038-0
E. Bujdosó , L. Medveczky
{"title":"Apparatus for processing nuclear emulsions","authors":"E. Bujdosó ,&nbsp;L. Medveczky","doi":"10.1016/0369-643X(58)90038-0","DOIUrl":"10.1016/0369-643X(58)90038-0","url":null,"abstract":"<div><p>The authors built an apparatus for processing nuclear emulsions. Its functioning is shown by describing the processing of an Agfa K2 emulsion of 200 μ thickness.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 270-274"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90038-0","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75941003","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Pulsed high-intensity ion source 脉冲高强度离子源
Nuclear Instruments Pub Date : 1958-04-01 DOI: 10.1016/0369-643X(58)90033-1
Jan Flinta
{"title":"Pulsed high-intensity ion source","authors":"Jan Flinta","doi":"10.1016/0369-643X(58)90033-1","DOIUrl":"https://doi.org/10.1016/0369-643X(58)90033-1","url":null,"abstract":"<div><p>The first part of this publication deals with the limitations of the discharge current, extraction of ions and focusing of large ion current beams. Three types of ion sources are described and their data are given.</p><p>The second part<sup>††</sup> deals with detailed investigation of the characteristics of the discharge of the Penning type. For this purpose a special ion source was build which allowed for the exchange of all inner parts.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"2 3","pages":"Pages 219-226"},"PeriodicalIF":0.0,"publicationDate":"1958-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90033-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"92109465","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信