Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)最新文献

筛选
英文 中文
Feasibility of Single-Input Tracer Kinetic Modeling with Continuous-Time Formalism in Liver 4-Phase Dynamic Contrast-Enhanced CT. 肝脏四期动态增强CT连续时间形式单输入示踪动力学建模的可行性。
Sang Ho Lee, Yasuji Ryu, Koichi Hayano, Hiroyuki Yoshida
{"title":"Feasibility of Single-Input Tracer Kinetic Modeling with Continuous-Time Formalism in Liver 4-Phase Dynamic Contrast-Enhanced CT.","authors":"Sang Ho Lee,&nbsp;Yasuji Ryu,&nbsp;Koichi Hayano,&nbsp;Hiroyuki Yoshida","doi":"10.1007/978-3-319-13692-9_6","DOIUrl":"https://doi.org/10.1007/978-3-319-13692-9_6","url":null,"abstract":"<p><p>The modeling of tracer kinetics with use of low-temporal-resolution data is of central importance for patient dose reduction in dynamic contrast-enhanced CT (DCE-CT) study. Tracer kinetic models of the liver vary according to the physiologic assumptions imposed on the model, and they can substantially differ in the ways how the input for blood supply and tissue compartments are modeled. In this study, single-input flow-limited (FL), Tofts-Kety (TK), extended TK (ETK), Hayton-Brady (HB), two compartment exchange (2CX), and adiabatic approximation to the tissue homogeneity (AATH) models were applied to the analysis of liver 4-phase DCE-CT data with fully continuous-time parameter formulation, including the bolus arrival time. The bolus arrival time for the 2CX and AATH models was described by modifying the vascular transport operator theory. Initial results indicate that single-input tracer kinetic modeling is feasible for distinguishing between hepatocellular carcinoma and normal liver parenchyma.</p>","PeriodicalId":91045,"journal":{"name":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","volume":"8676 ","pages":"62-73"},"PeriodicalIF":0.0,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/978-3-319-13692-9_6","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33891518","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Application of Pseudo-enhancement Correction to Virtual Monochromatic CT Colonography. 伪增强校正在虚拟单色CT结肠造影中的应用。
Rie Tachibana, Janne J Näppi, Hiroyuki Yoshida
{"title":"Application of Pseudo-enhancement Correction to Virtual Monochromatic CT Colonography.","authors":"Rie Tachibana,&nbsp;Janne J Näppi,&nbsp;Hiroyuki Yoshida","doi":"10.1007/978-3-319-13692-9_16","DOIUrl":"https://doi.org/10.1007/978-3-319-13692-9_16","url":null,"abstract":"<p><p>In CT colonography, orally administered positive-contrast fecal-tagging agents are used for differentiating residual fluid and feces from true lesions. However, the presence of high-density tagging agent in the colon can introduce erroneous artifacts, such as local pseudo-enhancement and beam-hardening, on the reconstructed CT images, thereby complicating reliable detection of soft-tissue lesions. In dual-energy CT colonography, such image artifacts can be reduced by the calculation of virtual monochromatic CT images, which provide more accurate quantitative attenuation measurements than conventional single-energy CT colonography. In practice, however, virtual monochromatic images may still contain some pseudo-enhancement artifacts, and efforts to minimize radiation dose may enhance such artifacts. In this study, we evaluated the effect of image-based pseudo-enhancement post-correction on virtual monochromatic images in standard-dose and low-dose dual-energy CT colonography. The mean CT values of the virtual monochromatic standard-dose CT images of 51 polyps and those of the virtual monochromatic low-dose CT images of 20 polyps were measured without and with the pseudo-enhancement correction. Statistically significant differences were observed between uncorrected and pseudo-enhancement-corrected images of polyps covered by fecal tagging in standard-dose CT (p < 0.001) and in low-dose CT (p < 0.05). The results indicate that image-based pseudo-enhancement post-correction can be useful for optimizing the performance of image-processing applications in virtual monochromatic CT colonography.</p>","PeriodicalId":91045,"journal":{"name":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","volume":"8676 ","pages":"169-178"},"PeriodicalIF":0.0,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521398/pdf/nihms671806.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33957886","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Information-Preserving Pseudo-Enhancement Correction for Non-Cathartic Low-Dose Dual-Energy CT Colonography. 非泻性低剂量双能CT结肠镜检查的保信息伪增强校正。
Janne J Näppi, Rie Tachibana, Daniele Regge, Hiroyuki Yoshida
{"title":"Information-Preserving Pseudo-Enhancement Correction for Non-Cathartic Low-Dose Dual-Energy CT Colonography.","authors":"Janne J Näppi,&nbsp;Rie Tachibana,&nbsp;Daniele Regge,&nbsp;Hiroyuki Yoshida","doi":"10.1007/978-3-319-13692-9_15","DOIUrl":"https://doi.org/10.1007/978-3-319-13692-9_15","url":null,"abstract":"<p><p>In CT colonography (CTC), orally administered positive-contrast fecal-tagging agents can cause artificial elevation of the observed radiodensity of adjacent soft tissue. Such pseudo-enhancement makes it challenging to differentiate polyps and folds reliably from tagged materials, and it is also present in dual-energy CTC (DE-CTC). We developed a method that corrects for pseudo-enhancement on DE-CTC images without distorting the dual-energy information contained in the data. A pilot study was performed to evaluate the effect of the method visually and quantitatively by use of clinical non-cathartic low-dose DE-CTC data from 10 patients including 13 polyps covered partially or completely by iodine-based fecal tagging. The results indicate that the proposed method can be used to reduce the pseudo-enhancement distortion of DE-CTC images without losing material-specific dual-energy information. The method has potential application in improving the accuracy of automated image-processing applications, such as computer-aided detection and virtual bowel cleansing in CTC.</p>","PeriodicalId":91045,"journal":{"name":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","volume":"8676 ","pages":"159-168"},"PeriodicalIF":0.0,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/978-3-319-13692-9_15","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33957884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信