{"title":"肝脏四期动态增强CT连续时间形式单输入示踪动力学建模的可行性。","authors":"Sang Ho Lee,&nbsp;Yasuji Ryu,&nbsp;Koichi Hayano,&nbsp;Hiroyuki Yoshida","doi":"10.1007/978-3-319-13692-9_6","DOIUrl":null,"url":null,"abstract":"<p><p>The modeling of tracer kinetics with use of low-temporal-resolution data is of central importance for patient dose reduction in dynamic contrast-enhanced CT (DCE-CT) study. Tracer kinetic models of the liver vary according to the physiologic assumptions imposed on the model, and they can substantially differ in the ways how the input for blood supply and tissue compartments are modeled. In this study, single-input flow-limited (FL), Tofts-Kety (TK), extended TK (ETK), Hayton-Brady (HB), two compartment exchange (2CX), and adiabatic approximation to the tissue homogeneity (AATH) models were applied to the analysis of liver 4-phase DCE-CT data with fully continuous-time parameter formulation, including the bolus arrival time. The bolus arrival time for the 2CX and AATH models was described by modifying the vascular transport operator theory. Initial results indicate that single-input tracer kinetic modeling is feasible for distinguishing between hepatocellular carcinoma and normal liver parenchyma.</p>","PeriodicalId":91045,"journal":{"name":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","volume":"8676 ","pages":"62-73"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/978-3-319-13692-9_6","citationCount":"0","resultStr":"{\"title\":\"Feasibility of Single-Input Tracer Kinetic Modeling with Continuous-Time Formalism in Liver 4-Phase Dynamic Contrast-Enhanced CT.\",\"authors\":\"Sang Ho Lee,&nbsp;Yasuji Ryu,&nbsp;Koichi Hayano,&nbsp;Hiroyuki Yoshida\",\"doi\":\"10.1007/978-3-319-13692-9_6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The modeling of tracer kinetics with use of low-temporal-resolution data is of central importance for patient dose reduction in dynamic contrast-enhanced CT (DCE-CT) study. Tracer kinetic models of the liver vary according to the physiologic assumptions imposed on the model, and they can substantially differ in the ways how the input for blood supply and tissue compartments are modeled. In this study, single-input flow-limited (FL), Tofts-Kety (TK), extended TK (ETK), Hayton-Brady (HB), two compartment exchange (2CX), and adiabatic approximation to the tissue homogeneity (AATH) models were applied to the analysis of liver 4-phase DCE-CT data with fully continuous-time parameter formulation, including the bolus arrival time. The bolus arrival time for the 2CX and AATH models was described by modifying the vascular transport operator theory. Initial results indicate that single-input tracer kinetic modeling is feasible for distinguishing between hepatocellular carcinoma and normal liver parenchyma.</p>\",\"PeriodicalId\":91045,\"journal\":{\"name\":\"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)\",\"volume\":\"8676 \",\"pages\":\"62-73\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/978-3-319-13692-9_6\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/978-3-319-13692-9_6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/978-3-319-13692-9_6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用低时间分辨率数据的示踪动力学建模对于动态对比增强CT (DCE-CT)研究中患者剂量减少至关重要。肝脏的示踪动力学模型根据施加在模型上的生理假设而变化,它们在血液供应输入和组织室的建模方式上可能有很大的不同。本研究采用单输入限流(FL)、Tofts-Kety (TK)、扩展TK (ETK)、Hayton-Brady (HB)、两室交换(2CX)和组织均匀性绝热近似(AATH)模型分析肝脏4期DCE-CT数据,并采用全连续时间参数公式,包括丸到达时间。通过修正血管运输算子理论,描述了2CX和AATH模型的药物到达时间。初步结果表明,单输入示踪动力学模型可用于区分肝细胞癌和正常肝实质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Feasibility of Single-Input Tracer Kinetic Modeling with Continuous-Time Formalism in Liver 4-Phase Dynamic Contrast-Enhanced CT.

Feasibility of Single-Input Tracer Kinetic Modeling with Continuous-Time Formalism in Liver 4-Phase Dynamic Contrast-Enhanced CT.

Feasibility of Single-Input Tracer Kinetic Modeling with Continuous-Time Formalism in Liver 4-Phase Dynamic Contrast-Enhanced CT.

The modeling of tracer kinetics with use of low-temporal-resolution data is of central importance for patient dose reduction in dynamic contrast-enhanced CT (DCE-CT) study. Tracer kinetic models of the liver vary according to the physiologic assumptions imposed on the model, and they can substantially differ in the ways how the input for blood supply and tissue compartments are modeled. In this study, single-input flow-limited (FL), Tofts-Kety (TK), extended TK (ETK), Hayton-Brady (HB), two compartment exchange (2CX), and adiabatic approximation to the tissue homogeneity (AATH) models were applied to the analysis of liver 4-phase DCE-CT data with fully continuous-time parameter formulation, including the bolus arrival time. The bolus arrival time for the 2CX and AATH models was described by modifying the vascular transport operator theory. Initial results indicate that single-input tracer kinetic modeling is feasible for distinguishing between hepatocellular carcinoma and normal liver parenchyma.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信