JMIR biomedical engineering最新文献

筛选
英文 中文
Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study 使用可量化的上肢运动学来确定Oculus触摸控制器用于运动康复应用的准确性:验证研究
JMIR biomedical engineering Pub Date : 2019-01-01 DOI: 10.2196/12291
Leia C. Shum, Bulmaro A. Valdés, H. V. D. Van der Loos
{"title":"Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study","authors":"Leia C. Shum, Bulmaro A. Valdés, H. V. D. Van der Loos","doi":"10.2196/12291","DOIUrl":"https://doi.org/10.2196/12291","url":null,"abstract":"Background: As commercial motion tracking technology becomes more readily available, it is necessary to evaluate the accuracy of these systems before using them for biomechanical and motor rehabilitation applications. Objective: This study aimed to evaluate the relative position accuracy of the Oculus Touch controllers in a 2.4 x 2.4 m play-space. Methods: Static data samples (n=180) were acquired from the Oculus Touch controllers at step sizes ranging from 5 to 500 mm along 16 different points on the play-space floor with graph paper in the x (width), y (height), and z (depth) directions. The data were compared with reference values using measurements from digital calipers, accurate to 0.01 mm; physical blocks, for which heights were confirmed with digital calipers; and for larger step sizes (300 and 500 mm), a ruler with hatch marks to millimeter units. Results: It was found that the maximum position accuracy error of the system was 3.5 ± 2.5 mm at the largest step size of 500 mm along the z-axis. When normalized to step size, the largest error found was 12.7 ± 9.9% at the smallest step size in the y-axis at 6.23 mm. When the step size was <10 mm in any direction, the relative position accuracy increased considerably to above 2% (approximately 2 mm at maximum). An average noise value of 0.036 mm was determined. A comparison of these values to cited visual, goniometric, and proprioceptive resolutions concludes that this system is viable for tracking upper-limb movements for biomechanical and rehabilitation applications. The accuracy of the system was also compared with accuracy values from previous studies using other commercially available devices and a multicamera, marker-based professional motion tracking system. Conclusions: The study found that the linear position accuracy of the Oculus Touch controllers was within an agreeable range for measuring human kinematics in rehabilitative upper-limb exercise protocols. Further testing is required to ascertain acceptable repeatability in multiple sessions and rotational accuracy. (JMIR Biomed Eng 2019;4(1):e12291) doi: 10.2196/12291","PeriodicalId":87288,"journal":{"name":"JMIR biomedical engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"68428666","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Auralife Instant Blood Pressure App in Measuring Resting Heart Rate: Validation Study 测量静息心率的Auralife即时血压应用程序:验证研究
JMIR biomedical engineering Pub Date : 2018-11-21 DOI: 10.2196/11057
T. Plante, Anna C. O'Kelly, Bruno Urrea, Zane T. Macfarlane, L. Appel, Edgar R Miller III, R. Blumenthal, S. Martin
{"title":"Auralife Instant Blood Pressure App in Measuring Resting Heart Rate: Validation Study","authors":"T. Plante, Anna C. O'Kelly, Bruno Urrea, Zane T. Macfarlane, L. Appel, Edgar R Miller III, R. Blumenthal, S. Martin","doi":"10.2196/11057","DOIUrl":"https://doi.org/10.2196/11057","url":null,"abstract":"Background: mHealth apps that measure heart rate using pulse photoplethysmography (PPG) are classified as class II (moderate-risk) Food and Drug Administration devices; therefore, these devices need clinical validation prior to public release. The Auralife Instant Blood Pressure app (AuraLife IBP app) is an mHealth app that measures blood pressure inaccurately based on a previous validation study. Its ability to measure heart rate has not been previously reported. Objective: The objective of our study was to assess the accuracy and precision of the AuraLife IBP app in measuring heart rate. Methods: We enrolled 85 adults from ambulatory clinics. Two measurements were obtained using the AuraLife IBP app, and 2 other measurements were achieved with a oscillometric device. The order of devices was randomized. Accuracy was assessed by calculating the relative and absolute mean differences between heart rate measurements obtained using each AuraLife IBP app and an average of both standard heart rate measurements. Precision was assessed by calculating the relative and absolute mean differences between individual measurements in the pair for each device. Results: The relative and absolute mean (SD) differences between the devices were 1.1 (3.5) and 2.8 (2.4) beats per minute (BPM), respectively. Meanwhile, the within-device relative and absolute mean differences, respectively, were <0.1 (2.2) and 1.7 (1.4) BPM for the standard device and −0.1 (3.2) and 2.2 (2.3) BPM for the AuraLife IBP app. Conclusions: The AuraLife IBP app had a high degree of accuracy and precision in the measurement of heart rate. This supports the use of PPG technology in smartphones for monitoring resting heart rate. (JMIR Biomed Eng 2018;3(1):e11057) doi: 10.2196/11057","PeriodicalId":87288,"journal":{"name":"JMIR biomedical engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42189482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Relationship Between the Applied Occlusal Load and the Size of Markings Produced Due to Occlusal Contact Using Dental Articulating Paper and T-Scan: Comparative Study 咬合载荷与咬合接触产生的标记尺寸之间的关系——使用牙咬合纸和T型扫描的比较研究
JMIR biomedical engineering Pub Date : 2018-10-02 DOI: 10.2196/11347
Shravya Reddy, P. Kumar, Vyoma Venkatesh Grandhi
{"title":"Relationship Between the Applied Occlusal Load and the Size of Markings Produced Due to Occlusal Contact Using Dental Articulating Paper and T-Scan: Comparative Study","authors":"Shravya Reddy, P. Kumar, Vyoma Venkatesh Grandhi","doi":"10.2196/11347","DOIUrl":"https://doi.org/10.2196/11347","url":null,"abstract":"Background: The proposed experimental design was devised to determine whether a relationship exists between the occlusal load applied and the size of the markings produced from tooth contact when dental articulating paper and T-Scan are interposed alternatively. Objective: The objective of our study was to compare the relationship between contact markings on an articulating paper and T-Scan for an applied occlusal load. Methods: In this in vitro study, dentulous maxillary and mandibular dies were mounted on a metal jig and articulating paper and T-Scan sensor were placed alternatively between the casts. Loads simulating occlusal loads began at 25 N and incrementally continued up to 450 N. The resultant markings (180 marks resulting from articulating paper and 138 from T-Scan) were photographed, and the marks were analyzed using MOTIC image analysis and sketching software. Descriptive statistical analyses were performed using one-way analysis of variance, Student t test, and Pearson correlation coefficient method. Results: Statistical interpretation of the data indicated that with articulating paper, the mark area increased nonlinearly with increasing load and there was a false-positive result. The characteristics of the paper mark appearance did not describe the amount of occlusal load present on a given tooth. The contact marking obtained using T-Scan for an applied occlusal load indicated that the mark area increased with increase in the load and provided more predictable results of actual load content within the occlusal contact. Conclusions: The size of an articulating paper mark may not be a reliable predictor of the actual load content within the occlusal contact, whereas a T-Scan provides more predictable results of the actual load content within the occlusal contact. (JMIR Biomed Eng 2018;3(1):e11347) doi: 10.2196/11347","PeriodicalId":87288,"journal":{"name":"JMIR biomedical engineering","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2018-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44541231","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信