{"title":"[Anatomic variations of the bile ducts: MRCP findings].","authors":"Ebru Düşünceli, Ayşe Erden, Ilhan Erden","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Anatomic variations of intra or extrahepatic bile ducts may be problematic during surgical procedures. Besides iatrogenic trauma of the bile ducts during cholecystectomy, formation of bile duct stones, recurrent pancreatitis, cholangitis and biliary malignancies can be seen. The aim of this study was to evaluate the frequency of anatomic variations of the biliary tree and to present the magnetic resonance cholangiopancreatography (MRCP) findings.</p><p><strong>Materials and methods: </strong>Between July 2000 and April 2004, 581 patients suspected to have pancreatobiliary disease, were referred to our MR unit. Four hundred and seventy-five patients with ages ranging from 22 to 88 (median: 56) were included in the study retrospectively. MRCP was performed on a 1 Tesla MR unit, using phased-array coil for signal detection. Heavily T2 weighted images were obtained with SSFSE technique. Axial and coronal source images and reformatted images were all evaluated together for the possibility of any anatomic variation.</p><p><strong>Results: </strong>Anatomic variations at different levels of biliary tree were found in 115 patients (24.2%). MRCP showed an aberrant right hepatic duct in 23 patients (4.8%), a right posterior hepatic duct in 27 patients (5.7%), trifurcation in 4 patients (0.8%), a long cystic duct in 8 patients (1.7%), a medial cystic duct insertion in 3 patients (0.63%), a low medial cystic duct insertion in 18 patients (3.8%), a short cystic duct in 1 patient (0.2%), a high localized gallbladder in 5 patients (1%), a vascular compression of common hepatic duct in 12 patients (2.5%), a pancreatobiliary junction anomaly in 3 patients (0.63%). Eleven patients had more than one anatomic variation (2.3%).</p><p><strong>Conclusion: </strong>MRCP is a useful, rapid, and non-invasive method for demonstrating the anatomy and the variations of the biliary tree. Diagnosis of these anatomic variations prior to surgical procedures may prevent iatrogenic injury to bile ducts.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 4","pages":"296-303"},"PeriodicalIF":0.0,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"24871397","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Can Cevikol, Kamil Karaali, Gökhan Esen, Ali Apaydin, Merter Ozenci, Utku Senol, Oğuz Bircan
{"title":"[MR imaging of meniscal tears at low-field (0.35 T) and high-field (1.5 T) MR units].","authors":"Can Cevikol, Kamil Karaali, Gökhan Esen, Ali Apaydin, Merter Ozenci, Utku Senol, Oğuz Bircan","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the effectivity of low (0.35 T) and high (1.5 T) field magnetic resonance imaging units in detecting meniscal tears.</p><p><strong>Materials and methods: </strong>Forty-eight knee MR imaging examinations performed in low field MR unit and 76 examinations performed in high field unit were retrospectively evaluated. MR results were compared with arthroscopy findings in all patients.</p><p><strong>Results: </strong>For medial meniscus tears, sensitivity, specificity and accuracy values were 93.7%, 87.5% and 91.6%, respectively in the low field unit. For lateral meniscus tears, these values were 87.5%, 95.0% and 93.7%, respectively. In the high field unit (1.5 T), sensitivity, specificity and accuracy for the detection of medial meniscus tears were 96.6%, 88.2% and 94.7%, respectively. For lateral meniscus tears, these values were 71.4%, 98.5% and 96.0%, respectively. There was no statistically significant difference between high and low field units in the detection of medial and lateral meniscus tears.</p><p><strong>Conclusion: </strong>We think that low field MR units are as effective as high field units in the evaluation of meniscus tears.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 4","pages":"316-9"},"PeriodicalIF":0.0,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"24871400","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"[Late presentation of an extrarenal pseudoaneurysm in a renal transplant patient: CT and color Doppler US findings (case report)].","authors":"Ebru Düşünceli, Cetin Atasoy, Suat Fitoz, Cemil Yağci","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Vascular complications associated with renal transplants are a significant cause of graft dysfunction or failure. The most common complications are arterial and venous stenoses/thromboses, intrarenal and extrarenal arteriovenous fistulas, and pseudoaneurysms. In this case report, an extremely rare complication following renal transplantation, an extrarenal pseudoaneurysm, is presented with CT, gray scale, and color Doppler US findings.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 4","pages":"289-91"},"PeriodicalIF":0.0,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"24871395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mehmet Tekşam, Esra Meltem Kayahan, Hasan Yerli, A Muhteşem Ağildere
{"title":"[Brain MR perfusion and MR spectroscopy in differentiation of radiation necrosis from tumor recurrence (case report)].","authors":"Mehmet Tekşam, Esra Meltem Kayahan, Hasan Yerli, A Muhteşem Ağildere","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>It is not always possible to differentiate tumor recurrence from radiation necrosis using conventional MR images. In this report we present a case of pathologically proven radiation necrosis which appeared as nodular contrast enhancement on conventional MR images in a patient who was surgically treated for grade II astrocytoma 5 years ago. There were decreased choline, creatine and N-acetyl aspartate peaks and significantly increased lipid peak on multivoxel H1-MR spectroscopy while there was no significant perfusion increase on MR perfusion. These findings suggested changes secondary to radiation necrosis.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 4","pages":"263-7"},"PeriodicalIF":0.0,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"24872044","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Halil Sevinç, Mustafa Oztürk, Ertuğrul Mavili, Irfan Ozyazgan
{"title":"[Gorlin syndrome with osteoma in the maxillary sinus (case report)].","authors":"Halil Sevinç, Mustafa Oztürk, Ertuğrul Mavili, Irfan Ozyazgan","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Gorlin syndrome is a rare autosomal dominant disorder characterized by multiple basal cell carcinomas of the skin, odontogenic keratocysts of the jaw, various skeletal abnormalities, and lamellar falx calsifications. Many associated lesions have been reported. In this report, we present a case of Gorlin syndrome with an osteoma in the maxillary sinus which has never been reported in the literature.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 4","pages":"268-71"},"PeriodicalIF":0.0,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"24872045","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Bahri Ustünsöz, Uğur Bozlar, Murat Kocaoğlu, Turan Ilica, Mehmet Dakak
{"title":"[Mechanical coil embolization of pulmonary arteriovenous malformations].","authors":"Bahri Ustünsöz, Uğur Bozlar, Murat Kocaoğlu, Turan Ilica, Mehmet Dakak","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To report our experience with mechanical coil embolization of pulmonary arteriovenous malformations (PAVM) MATERIAL AND METHODS: Coil embolizations were performed in 6 men (mean age 21.1, age range 20-23 years) with PAVM between 1999 and 2004. Five F Cobra catheters and various size coils were used for embolization. Clinically, cases were followed in every 3 months of their first year and 6 months in the following years with a mean time of 2.3 years.</p><p><strong>Results: </strong>Complete primary occlusion was achieved in all patients. There were no complications related to the procedure. No problem was reported in the follow-up period.</p><p><strong>Conclusion: </strong>Treatment of PAVM cases with coil embolization is a good option.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 4","pages":"328-31"},"PeriodicalIF":0.0,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"24871323","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mustafa Harman, Ekrem Algün, Hayati Ayakta, Mehmet Emin Sakarya, Omer Etlik
{"title":"[Multidetector computed tomography in the diagnosis of parathyroid adenomas: contribution of contrast enhancement pattern to diagnosis].","authors":"Mustafa Harman, Ekrem Algün, Hayati Ayakta, Mehmet Emin Sakarya, Omer Etlik","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>Contrast enhancement patterns of parathyroid adenomas in the arterial and venous phases were evaluated with multidetector computed tomography and specificity of the method to characterize the lesions was investigated.</p><p><strong>Materials and methods: </strong>Arterial and venous enhancement patterns of parathyroid adenomas were evaluated retrospectively with multidetector computed tomography in 12 patients. All adenomas were removed surgically and the diagnosis was confirmed histopathologically. An area from the mandibular angle to the aortic arch was scanned with 1.5 mm section thickness in the arterial phase (20 seconds delay time) and venous phase (70 seconds delay time) after bolus injection of 50 ml of iodinated contrast media. Arterial and venous contrast enhancement of parathyroid adenomas was evaluated in the axial and coronal reformat images.</p><p><strong>Results: </strong>Ten (83.3%) of 12 parathyroid adenomas showed a heterogeneous enhancement with a hypodense small central area in the arterial phase and a homogeneous enhancement in the venous phase. However, two small lesions, four and five mm in diameter respectively, showed homogeneous contrast enhancement in the arterial phase unlike the larger lesions which displayed a hypodense center in this phase.</p><p><strong>Conclusion: </strong>Dynamic scanning with multidetector computed tomography after contrast administration may be helpful in characterizing parathyroid adenomas.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 3","pages":"204-9"},"PeriodicalIF":0.0,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40907578","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Emel Alimoğlu, Mustafa Kemal Alimoğlu, Adnan Kabaalioğlu, Kağan Ceken, Ali Apaydin, Ersin Lüleci
{"title":"[Mammography-related pain and anxiety].","authors":"Emel Alimoğlu, Mustafa Kemal Alimoğlu, Adnan Kabaalioğlu, Kağan Ceken, Ali Apaydin, Ersin Lüleci","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether informing patients about mammographic compression changed the anxiety and pain that they experience during mammography.</p><p><strong>Materials and methods: </strong>Five hundred and one patients were enrolled in the study. Two hundred and fifty seven (51.3%) were informed before the procedure by written forms explaining the necessity of compression. The remaining 244 (48.7%) didn't get any pre-procedural information. All participants completed demographic form and Spielberger's State Anxiety Inventory while they were waiting for mammography. They marked the level of pain due to compression on a 100-mm visual analog scale (VAS) after the procedure. Chi square, Pearson's correlation and Student's t tests were used for statistical analyses.</p><p><strong>Results: </strong>We didn't find any significant difference between the anxiety scores of the informed (41.4+/-7.9) and uninformed (40.9+/-7.7) women, but the pain level was significantly lower in the informed group (16.5+/-22.4) than in the uninformed group (24.5+/-28.1). There was no statistically significant relationship between the anxiety and pain levels. Women who had recently felt tense and nervous or had a fear of breast cancer diagnosis had higher anxiety levels.</p><p><strong>Conclusion: </strong>Our data shows that informing patients about examination decreases the level of pain due to mammographic compression, but does not alter the anxiety level. The main cause of anxiety appears to be the fear of a malignant diagnosis. Any intervention to decrease this fear may increase the compliance rates for screening mammography.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 3","pages":"213-7"},"PeriodicalIF":0.0,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40907580","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"[Diagnostic efficiency of multislice computed tomography colonography in the detection of colorectal tumors: comparison with conventional colonography].","authors":"Bariş Bakir, Ensar Yekeler, Mehtap Tunaci, Atadan Tunaci, Bülent Acunaş, Gülden Acunaş","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the diagnostic efficiency of multislice CT colonography in the detection of colorectal tumors by comparing it with conventional colonography in patients with high risk of colorectal cancer.</p><p><strong>Materials and methods: </strong>Thirty-seven patients who had undergone conventional colonoscopy because of a suspicion of colorectal cancer were scanned with a four-detector multislice CT scanner with 4 x 1 mm detector collimation, 120 kV, 0.5 sec gantry rotation and 120 mAs scan parameters. Multiplanar reformatted images, virtual colonography and virtual colonoscopy images were compared with conventional colonoscopy. With conventional colonoscopy taken as the reference standard, the results were calculated with 95% confidence interval technique.</p><p><strong>Results: </strong>Seventeen of the 23 polyps detected in conventional colonoscopy were identified correctly with multislice CT. Nine of 11 lesions with a diameter of 10 mm or greater (81%), three of four lesions with a diameter of 6-9 mm (75%), and five of eight lesions with a diameter of 1-5 mm (62%) were correctly identified with multislice CT.</p><p><strong>Conclusion: </strong>Multislice CT colonography is a good alternative to other colorectal screening tests because it has high sensitivity for polyps 10 mm or larger in diameter, is relatively safe and minimally invasive.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 3","pages":"218-29"},"PeriodicalIF":0.0,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40909252","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kamran Mahmutyazicioğlu, Hüseyin Ozdemir, Ahmet Savranlar, Murat Sümer, Tuğrul Atasoy, Aysun Unal, Sadi Gündoğdu
{"title":"[Double inversion recovery sequence in temporal lobe epilepsy: preliminary results].","authors":"Kamran Mahmutyazicioğlu, Hüseyin Ozdemir, Ahmet Savranlar, Murat Sümer, Tuğrul Atasoy, Aysun Unal, Sadi Gündoğdu","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Purpose: </strong>DIR (double inversion recovery) is a sequence with the hybrid contrast of both FLAIR and STIR sequences, produced by the application of double inversion recovery pulse. It has been suggested that DIR provides high sensitivity to lesions with low T2 contrast. The purpose of this study was to test the hypothesis that DIR sequence is superior to conventional sequences in the identification of mesial temporal sclerosis and other temporal lobe lesions in patients with temporal lobe epilepsy.</p><p><strong>Materials and methods: </strong>Thirty-three subjects with a prediagnosis of temporal lobe epilepsy and ten healthy control subjects with no abnormality on magnetic resonance imaging studies have been studied with DIR, FLAIR and T2W sequences. Coronal images through temporal lobes and hippocampus were acquired. Qualitatively, overall sensitivity to the presence of lesions, hippocampal lesion detectability, temporal horn dilatation and artifacts were evaluated in temporal lobe epilepsy cases and quantitatively, hippocampal and white matter signal-to-noise ratio as well as hippocampus-white matter contrast-to-noise ratio were calculated in the healthy subjects. Subjective scores were graded on a scale of 3 or 4 points.</p><p><strong>Results: </strong>Signal-to-noise ratio scores were higher on T2W sequence, however contrast-to-noise ratio scores were higher on DIR sequence compared to the other two sequences. Imaging findings were compatible with mesial temporal sclerosis in seven patients, tumoral mass in two, and chronic infarct in four. DIR sequence was less sensitive to hippocampal atrophy than the other two sequences because of cerebrospinal fluid artifacts. Overall sensitivity to the presence of lesions and hippocampal lesion detectability scores, although similar among three sequences, were highest with DIR sequence. However, lesion sensitivity scores were highest for lesions compatible with mesial temporal sclerosis and for solid masses and lowest for cystic lesions on DIR sequence.</p><p><strong>Conclusion: </strong>Despite the presence of artifacts, DIR is a sequence providing high sensitivity to mesial temporal sclerosis like lesions at hippocampus. DIR might be useful as an additional sequence when the other conventional sequences reveal a suspicious lesion with no accompanying hippocampal atrophy.</p>","PeriodicalId":87018,"journal":{"name":"Tanisal ve girisimsel radyoloji : Tibbi Goruntuleme ve Girisimsel Radyoloji Dernegi yayin organi","volume":"10 3","pages":"182-8"},"PeriodicalIF":0.0,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40907574","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}