{"title":"Ten favorite contact lens chapters","authors":"Milton M. Hom OD, FAAO","doi":"10.1016/S0892-8967(02)00071-8","DOIUrl":"10.1016/S0892-8967(02)00071-8","url":null,"abstract":"","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 4","pages":"Pages 137-138"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(02)00071-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"94206543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"From the earlier ages of oxygen: part 1: the cornea under glass","authors":"Richard M Hill OD, PhD","doi":"10.1016/S0892-8967(02)00064-0","DOIUrl":"10.1016/S0892-8967(02)00064-0","url":null,"abstract":"","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 4","pages":"Pages 135-136"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(02)00064-0","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"56183441","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A personal perspective on the history of contact lenses","authors":"Edward Goodlaw (OD, FAAO)","doi":"10.1016/S0892-8967(02)00085-8","DOIUrl":"10.1016/S0892-8967(02)00085-8","url":null,"abstract":"","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 4","pages":"Pages 139-145"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(02)00085-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"56183056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Recognition of former editors and board members","authors":"","doi":"10.1016/S0892-8967(02)00077-9","DOIUrl":"https://doi.org/10.1016/S0892-8967(02)00077-9","url":null,"abstract":"","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 4","pages":"Pages 109-111"},"PeriodicalIF":0.0,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(02)00077-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136779698","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Spectra of UV-absorbing contact lenses: relative performance","authors":"Hermann Faubl, Michael H. Quinn","doi":"10.1016/S0892-8967(01)00059-1","DOIUrl":"10.1016/S0892-8967(01)00059-1","url":null,"abstract":"<div><p>The ultraviolet (UV) transmission spectra of commercially available contact lenses were determined with methods developed to accurately and precisely make these measurements. Lenses were compared by their relative performance in the UVA, UVB, and total UV ranges. Other factors believed to be important were also compared. There is a large range of variability in the performance among lenses from different manufacturers. It was not possible to develop a single parameter to relate the ability of these lenses to absorb UV radiation with putative abilities to protect the ocular system. This article presents results of studies to show the data from accurate measurements of the amount of UV radiation transmitted by commercially available UV-blocking contact lenses. The listed results allow practitioners to recommend UV protection options from performance data.</p></div>","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 3","pages":"Pages 65-74"},"PeriodicalIF":0.0,"publicationDate":"2000-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(01)00059-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"56182972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Deposits and symptomatology with soft contact lens wear","authors":"Noel A. Brennan PhD, M.-L.Chantal Coles (OD)","doi":"10.1016/S0892-8967(01)00060-8","DOIUrl":"10.1016/S0892-8967(01)00060-8","url":null,"abstract":"<div><p>Techniques for eliciting the identity and amount of deposits on soft contact lenses have improved consistently; however, there remain many questions regarding the role of specific deposit components in causing ocular reactions. We review the large body of literature on soft lens deposition to define the link between deposits and symptoms.</p><p>Our critique attempts to clarify areas of doubt in previous methodologies for analyzing deposits, and to focus on the aspects of deposition as relevant to inducing ocular responses. The principal features confounding previous experimentation are: variables in experimental design; methodological flaws, such as imperfect extraction of material from a lens; focus on determining the quantity of a component at the expense of considering its nature and biological activity; reporting of results from nonrepresentative wearing conditions and lenses.</p><p>Despite the introduction of disposable lenses, lens surface build-up remains an important factor in determining lens-wear success. The composition of deposits has been the target of many studies that show that lysozyme is the principal soilant on the lens surface. Estimates of protein quantities found on lenses are subject to the extraction technique but provide the common finding that Group IV lenses attract the greatest level of deposit. Nonionic lens surfaces have a greater affinity for lipids. The extent to which other species such as carbohydrates and minerals, contribute to lens deposits is less well defined. There are some clues to the structural basis for deposit formation, but further research is necessary to isolate the key events leading to deposits.</p><p>The sheer weight of energy that has been invested into examining lens coatings suggests that surface build-up plays a role in contact lens complications, although proof linking a specific component with a specific biocompatibility issue remains lacking. Emphasis should be placed on determining the nature, as well as quantity, of lens deposit components and on the development of clinical methods that can link symptomatology with derived deposit patterns.</p></div>","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 3","pages":"Pages 75-100"},"PeriodicalIF":0.0,"publicationDate":"2000-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(01)00060-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"56182627","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dk/t: closed eye equivalents","authors":"Richard M Hill OD, PhD","doi":"10.1016/S0892-8967(02)00057-3","DOIUrl":"10.1016/S0892-8967(02)00057-3","url":null,"abstract":"","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"27 3","pages":"Pages 101-102"},"PeriodicalIF":0.0,"publicationDate":"2000-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(02)00057-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"56182661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}