The Journal of critical illness最新文献

筛选
英文 中文
The technique of inverse ratio ventilation. Steps to improve oxygenation and decrease dead space ventilation. 逆比通风技术。改善氧合和减少死腔通气的步骤。
The Journal of critical illness Pub Date : 1992-06-01
M Johnson, R D Cane
{"title":"The technique of inverse ratio ventilation. Steps to improve oxygenation and decrease dead space ventilation.","authors":"M Johnson,&nbsp;R D Cane","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Inverse ratio ventilation (IRV) differs from other ventilatory techniques in that it employs a prolonged inspiratory time. In theory, pressure-control IRV allows you to maintain ventilation and oxygenation with lower peak airway and end-expiratory pressures; this may reduce the potential for lung damage secondary to shearing forces. Consider pressure-control IRV for patients with acute lung disease characterized by low lung compliance, diffuse microatelectasis, and increased intrapulmonary shunting. Currently, the chief limitation of this technique is that the patient cannot breathe spontaneously during its use. The best inspiratory to expiratory ratio is the shortest inspiratory time that improves oxygenation with minimal hemodynamic compromise; depression of cardiac output will negate any potential improvement in arterial oxygenation.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 6","pages":"969-73"},"PeriodicalIF":0.0,"publicationDate":"1992-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Getting best results from echocardiography in emergency situations. Indications include shock, infarction, heart failure, trauma, tamponade. 在紧急情况下使用超声心动图获得最佳结果。适应症包括休克、梗塞、心力衰竭、外伤、心包填塞。
The Journal of critical illness Pub Date : 1992-05-01
P R Liebson, T H Karson
{"title":"Getting best results from echocardiography in emergency situations. Indications include shock, infarction, heart failure, trauma, tamponade.","authors":"P R Liebson,&nbsp;T H Karson","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In the ICU, both transthoracic and transesophageal echocardiography can assist in the acute management of a number of different disorders. In hypotensive patients, echocardiography helps distinguish between cardiogenic shock (resulting from acute myocardial infarction), septic shock, and circulatory shock (associated with a reduction in circulating blood volume); it can also help determine whether pericardial effusion or obstruction to valvular flow is producing the hypotension and suggesting pulmonary embolus. Other roles for echocardiography include differentiating left- and right-sided heart failure, assessing the extent of pericardial disease, diagnosing disorders of the thoracic aorta, and evaluating traumatic heart disease.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 5","pages":"698-710"},"PeriodicalIF":0.0,"publicationDate":"1992-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020532","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
How best to use echocardiography for definitive assessment. Methods of estimating valvular integrity, LV function, pulmonary pressure. 如何最好地使用超声心动图进行明确的评估。评估瓣膜完整性,左室功能,肺动脉压的方法。
The Journal of critical illness Pub Date : 1992-05-01
P R Liebson, T H Karson
{"title":"How best to use echocardiography for definitive assessment. Methods of estimating valvular integrity, LV function, pulmonary pressure.","authors":"P R Liebson,&nbsp;T H Karson","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In patients with myocardial infarction, echocardiography helps predict outcome, as well as guide the selection of interventional strategies. By assessing the extent of valvular dysfunction and abnormalities in LV and RV size and function, echocardiography can help determine whether surgery is needed in patients with valvular heart disease. Both pulmonary artery pressures and LV function can be evaluated and quantified with ultrasonically derived data. Although echocardiography cannot document active infection, vegetations may appear as areas of valvular thickening. The role of echocardiography will continue to evolve as new techniques are developed.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 5","pages":"715-28"},"PeriodicalIF":0.0,"publicationDate":"1992-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Beyond the basics: operating the new generation of ventilator. A look at the features and functions of these units. 除此之外:操作新一代的呼吸机。看看这些单元的特点和功能。
The Journal of critical illness Pub Date : 1992-05-01
R C Bone, D H Eubanks, E Gluck
{"title":"Beyond the basics: operating the new generation of ventilator. A look at the features and functions of these units.","authors":"R C Bone,&nbsp;D H Eubanks,&nbsp;E Gluck","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Most modern ventilators have several key features in common: microprocessor control of operational and monitoring functions; electromechanical valves to control and adjust gas flow patterns; and extensive monitoring systems. In addition, these machines can provide a number of different modes of ventilation (including pressure support). Though not microprocessor-controlled, the Siemens Servo 900 series ventilators use feedback electronics to adjust inspiratory flow based on expiratory flow to meet preset volumes. In contrast, the Bennett 7200 units use microprocessor-regulated solenoid valves to deliver preset tidal volume. High-frequency ventilators deliver smaller tidal volumes at rates greater than 60 bpm.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 5","pages":"770-82; 787-8"},"PeriodicalIF":0.0,"publicationDate":"1992-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020534","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Techniques for IABP timing, use--and discontinuance. Counterpulsation can reduce ischemia and improve hemodynamics. IABP的时机、使用和终止技术。反搏可以减少缺血,改善血流动力学。
The Journal of critical illness Pub Date : 1992-04-01
M Sorrentino, T Feldman
{"title":"Techniques for IABP timing, use--and discontinuance. Counterpulsation can reduce ischemia and improve hemodynamics.","authors":"M Sorrentino,&nbsp;T Feldman","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>By restoring the balance between myocardial oxygen supply and demand, intra-aortic balloon counterpulsation can aid the ischemic or failing left ventricle. Rapid inflation and deflation of the balloon reduces afterload and improves coronary perfusion. Timing of inflation and deflation is adjusted according to the arterial pressure waveform. The balloon should inflate just after the aortic valve closes and deflate just before the aortic valve opens; early or late balloon inflation or deflation blunts the therapeutic effects. Discontinue the IABP support gradually; monitor the patient frequently for any signs of hemodynamic compromise, redevelopment of ischemic chest pain, or electrocardiographic changes.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 4","pages":"597-604"},"PeriodicalIF":0.0,"publicationDate":"1992-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Understanding and operating the Bennett MA-1 ventilator. Tips on adjusting the controls to avoid problems. 了解并操作班尼特MA-1呼吸机。调整控制以避免问题的技巧。
The Journal of critical illness Pub Date : 1992-04-01
R C Bone, D H Eubanks
{"title":"Understanding and operating the Bennett MA-1 ventilator. Tips on adjusting the controls to avoid problems.","authors":"R C Bone,&nbsp;D H Eubanks","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The Bennett MA-1 ventilator is a volume-cycled, constant flow generator that can act as an assistor, controller, or assist-controller. It is one of the most commonly used ventilators in clinical practice. With this unit, inspiration continues until a preset tidal volume is delivered to the patient--unless impedances to gas flow increase system pressures to a preselected limit. Thus, setting the maximum inspiratory pressure too low limits the ability of the ventilator to deliver the tidal volume, causing it to function as a pressure-cycled device. Other basic controls allow you to establish the sensitivity of the ventilator to spontaneous breathing attempts, the maximum flow rate, the frequency of respirations, and the oxygen percentage. Special controls permit delivery of a sigh breath and slowing of exhalation.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 4","pages":"547-60"},"PeriodicalIF":0.0,"publicationDate":"1992-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020535","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The technique of inserting an intra-aortic balloon pump. Indications, contraindications, advice for avoiding complications. 插入主动脉内球囊泵的技术。适应症,禁忌症,避免并发症的建议。
The Journal of critical illness Pub Date : 1992-03-01
A Benn, T Feldman
{"title":"The technique of inserting an intra-aortic balloon pump. Indications, contraindications, advice for avoiding complications.","authors":"A Benn,&nbsp;T Feldman","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The intra-aortic balloon pump (IABP) uses the timed inflation and deflation of a balloon placed in the descending aorta to augment coronary perfusion and reduce myocardial work. The IABP is useful in a number of settings, including acute myocardial ischemia, cardiogenic shock, and mechanical complications of acute myocardial infarction; it also provides support to perioperative patients. Because the device can be inserted percutaneously, mechanical circulatory support can be instituted rapidly Complications, most of which are reversible, occur in approximately 30% of patients.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 3","pages":"435-45"},"PeriodicalIF":0.0,"publicationDate":"1992-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020457","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Second- and third-generation ventilators: sorting through available options. When, and for which patients, are special functions needed? 第二代和第三代呼吸机:对可用选项进行分类。什么时候,哪些病人需要特殊功能?
The Journal of critical illness Pub Date : 1992-03-01
R C Bone, D H Eubanks
{"title":"Second- and third-generation ventilators: sorting through available options. When, and for which patients, are special functions needed?","authors":"R C Bone,&nbsp;D H Eubanks","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Currently available ventilators offer a number of special options to meet the needs of critically ill patients. Intermittent mandatory ventilation allows a patient to breathe spontaneously without assistance. CPAP and PEEP ensure that the patient breathes at an elevated pressure either constantly or during expiration. Pressure support ventilation allows patients to participate in breathing but provides inspiratory assistance and is most useful during weaning. Airway pressure release ventilation facilitates venous return and decreases airway pressure. Sophisticated monitors provide detailed information on the patient's status, but alarm features are somewhat unreliable. Thorough knowledge of the controls on modern ventilators can help you provide the optimum form of respiratory support.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 3","pages":"399-416"},"PeriodicalIF":0.0,"publicationDate":"1992-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020456","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A clinician's guide to ventilators: how they work and why they can fail. A classification system to make sense of available options. 临床医生的呼吸机指南:它们是如何工作的,为什么会失灵。一个分类系统,使可用选项有意义。
The Journal of critical illness Pub Date : 1992-03-01
R C Bone, D H Eubanks
{"title":"A clinician's guide to ventilators: how they work and why they can fail. A classification system to make sense of available options.","authors":"R C Bone,&nbsp;D H Eubanks","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>To select a ventilator (or a ventilatory mode), consider the most basic characteristics: How is tidal volume generated (with a constant or nonconstant flow or pressure generator)? How does the ventilator trigger a changeover from exhalation to inhalation and cycle back to exhalation? How is tidal volume delivered to the patient (either directly from a power source or indirectly from an intermediate chamber)? What special functions are available? The answers to these questions will not only let you make the best selection but will also help you troubleshoot when a ventilator fails to function properly.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 3","pages":"379-82, 387-94"},"PeriodicalIF":0.0,"publicationDate":"1992-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020537","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The technique of percutaneous renal biopsy. How to minimize risk while ensuring adequate tissue sampling. 经皮肾活检技术。如何在确保足够的组织取样的同时将风险降到最低。
The Journal of critical illness Pub Date : 1992-02-01
K A Griffin
{"title":"The technique of percutaneous renal biopsy. How to minimize risk while ensuring adequate tissue sampling.","authors":"K A Griffin","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Percutaneous renal biopsy is useful in diagnosing a variety of kidney disorders, as well as certain systemic diseases with renal and/or nonrenal manifestations. The procedure is performed while the kidney is viewed by continuous ultrasonographic imaging. The kidney is first located with a spinal needle and the area is anesthetized. The biopsy needle is then inserted and advanced toward the capsule. When the capsule is pierced, the trochar is advanced into the renal cortex. The sheath is lowered, encompassing the cutting edge and the core biopsy sample. Complications, although rare, may include the creation of an arteriovenous malformation and laceration of the kidney or other intra-abdominal organ; close monitoring after the procedure is therefore required.</p>","PeriodicalId":80210,"journal":{"name":"The Journal of critical illness","volume":"7 2","pages":"284-92"},"PeriodicalIF":0.0,"publicationDate":"1992-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020459","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信