Digitale Bilddiagnostik最新文献

筛选
英文 中文
[Magnetic resonance tomographic studies of stress fractures]. [应力裂缝的磁共振层析成像研究]。
Digitale Bilddiagnostik Pub Date : 1989-06-01
T Yousry, U Fink, S Breitner, A Stelzer, R Tiling, A Stäbler
{"title":"[Magnetic resonance tomographic studies of stress fractures].","authors":"T Yousry,&nbsp;U Fink,&nbsp;S Breitner,&nbsp;A Stelzer,&nbsp;R Tiling,&nbsp;A Stäbler","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Stress fractures can represent a diagnostic problem especially in their differentiation from bone tumours. 6 patients with 7 lesions were examined. MRI visualised the stress fractures and established the diagnosis of stress fracture vs. tumour in 6 cases. In the seventh, biopsy having been performed, a tumour was ruled out. MRI is more sensitive than radiography in the detection of stress fractures, showing the characteristic changes earlier. MRI, being a very sensitive method in the diagnosis of stress fractures and a reliable one in their differentiation from bone tumours, can be applied in cases of unusual clinical course and difficult radiological diagnosis prior to biopsy.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 2","pages":"69-71"},"PeriodicalIF":0.0,"publicationDate":"1989-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13892566","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Dose and time dependency of "CT clearance"]. [“CT清除”的剂量和时间依赖性]。
Digitale Bilddiagnostik Pub Date : 1989-06-01
H A Kaltenborn, K J Klose, C Dexheimer, von Steinijans
{"title":"[Dose and time dependency of \"CT clearance\"].","authors":"H A Kaltenborn,&nbsp;K J Klose,&nbsp;C Dexheimer,&nbsp;von Steinijans","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of \"CT clearance\" on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be preferred in future. The measurement interval can be limited to 10 minutes.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 2","pages":"72-5"},"PeriodicalIF":0.0,"publicationDate":"1989-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13892567","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Magnetic resonance tomography imaging of Botallo's duct--a case report]. [Botallo导管的磁共振断层成像- 1例报告]。
Digitale Bilddiagnostik Pub Date : 1989-03-01
T Yousry, B Bacherler, R Tiling, U Fink, K Werdan
{"title":"[Magnetic resonance tomography imaging of Botallo's duct--a case report].","authors":"T Yousry,&nbsp;B Bacherler,&nbsp;R Tiling,&nbsp;U Fink,&nbsp;K Werdan","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In a female patient suffering from renal insufficiency in whom angiography could not be performed, it was possible to confirm the diagnosis of a ductus arteriosus (Botallo's duct) by magnetic resonance imaging. The present case report shows that it is possible to visualise this congenital heart disease by MRI. This can be of importance especially if angiography cannot be performed (as in this case) because of renal insufficiency or because of contrast medium allergy.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"20-1"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13846568","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Validity testing of time-density curves in determining the degree of arterial stenosis by DSA]. [时间-密度曲线在DSA判断动脉狭窄程度中的有效性检验]。
Digitale Bilddiagnostik Pub Date : 1989-03-01
D Köhler, M Langer, C Spanger
{"title":"[Validity testing of time-density curves in determining the degree of arterial stenosis by DSA].","authors":"D Köhler,&nbsp;M Langer,&nbsp;C Spanger","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>106 patients with a stenosis of the carotid arteries or the common iliac arteries were examined by digital subtraction angiography. The haemodynamic effectiveness of a stenosis was supposed to be measured by time-density curves. Evaluation of time-density curves produced by videodensitometry did not allow to judge the degree of a stenosis of the carotid or the common iliac arteries. Causative for the insufficient accuracy of the results is a patient related change of examination quality. Disturbing factors are reduced cardiac output, moving artifacts, overshadowing of the examined region by air and reduced contrast due to obesity.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"36-41"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13791986","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[The inverted cockade sign. An indication in CT of an impending rupture of an abdominal aortic aneurysm]. [倒置的帽徽标志。CT显示腹主动脉瘤即将破裂的迹象]。
Digitale Bilddiagnostik Pub Date : 1989-03-01
U Lörcher
{"title":"[The inverted cockade sign. An indication in CT of an impending rupture of an abdominal aortic aneurysm].","authors":"U Lörcher","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A new CT-sign as a pointer to the imminent rupture of an abdominal aortic aneurysm is described: the enhanced shell of the thrombus of the aneurysm. This sign is caused by bleeding into the thrombotic layer.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"51-3"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13847768","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[MR tomography of the elbow joint]. [肘关节的MR断层扫描]。
Digitale Bilddiagnostik Pub Date : 1989-03-01
M Zwaan, E Rinast, H D Weiss, M Pressler, H Vogel
{"title":"[MR tomography of the elbow joint].","authors":"M Zwaan,&nbsp;E Rinast,&nbsp;H D Weiss,&nbsp;M Pressler,&nbsp;H Vogel","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>MR examinations of the elbow joint of three healthy subjects and a comparison with corresponding sections of anatomical preparations show that MR tomography enables not only an excellent differentiation of muscles, tendons and of the articular capsule, but will also visualise vessels and nerve tracts. MR tomography proved superior to the conventional methods in demonstration of separate fragments and inflammatory changes in the bone on examining 11 pathological elbow joints: congenital malformation, osteochondritis dissecans, ostitis, ulnar and radial nerve lesions, completely healed radius fracture and epicondylitis of the radial and ulnar humerus. Epicondylitis could not be demonstrated by MR. Magnetic resonance tomography seems to be the only method that enables direct visualisation of the nerve paths at the elbow joint.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"12-9"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13640065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Computed tomography findings in hereditary angioneurotic edema]. [遗传性血管神经性水肿的计算机断层扫描表现]。
Digitale Bilddiagnostik Pub Date : 1989-03-01
P Kullnig, G Melzer, G Porsch, F Strouhal, B Eber
{"title":"[Computed tomography findings in hereditary angioneurotic edema].","authors":"P Kullnig,&nbsp;G Melzer,&nbsp;G Porsch,&nbsp;F Strouhal,&nbsp;B Eber","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The authors describe the computer tomographic findings in a patient with proven hereditary angioneurotic edema of the gastrointestinal tract with emphasis on differential diagnoses.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"48-50"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13791988","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Postoperative computed tomography control of allogeneic vascular prostheses]. 异体血管假体术后计算机断层扫描控制。
Digitale Bilddiagnostik Pub Date : 1989-03-01
C Zwicker, M Langer, M Cordes, R Langer, W Hepp, R Felix
{"title":"[Postoperative computed tomography control of allogeneic vascular prostheses].","authors":"C Zwicker,&nbsp;M Langer,&nbsp;M Cordes,&nbsp;R Langer,&nbsp;W Hepp,&nbsp;R Felix","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>33 CT-studies of 26 patients with alloplastic vascular prostheses were evaluated and compared with postoperative digital subtraction-angiography in 16 cases. 13 patients had no pathologic findings confirmed by further clinical development. In 4 cases bypass infection was diagnosed, which CT findings were perigraft gas (2/4), perigraft fluid (4/4), cm-enhancement (4/4) and fistulas (2/4). 10-21 d. post.-op. sterile hematomas were found in 3 patients. Further 3 cases had 5 weeks-2 post.-op. perigraft seromas. CT was method of first choice for diagnostic of perivascular alterations after bypass surgery. DSA was complementary to CT and should be performed to detect vascular complications.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"42-7"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13847766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Magnetic resonance tomography flow measurement in cerebral arteriovenous angioma]. 脑动静脉血管瘤的磁共振断层成像血流测量。
Digitale Bilddiagnostik Pub Date : 1989-03-01
M Huber, D B Longmore, D N Firmin, J Assheuer, H Bewermeyer, W D Heiss
{"title":"[Magnetic resonance tomography flow measurement in cerebral arteriovenous angioma].","authors":"M Huber,&nbsp;D B Longmore,&nbsp;D N Firmin,&nbsp;J Assheuer,&nbsp;H Bewermeyer,&nbsp;W D Heiss","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A case of cerebral AVM associated with Klippel-Trenaunay Syndrome is presented where Magnetic Resonance (MRI) flow measurement revealed details of the shunt from the cerebral arterial system. The AVM was supplied by two arteries, the main flow came from the left vertebral and internal carotid artery. The arterial blood supply of the AVM was about 268 ml/min, the av-shunt flow was about 18% of the whole carotid and vertebral upstream flow.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"1-4"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13683379","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Picture quality of a digital urogram using image enhancement radiography]. [使用图像增强射线摄影技术的数字尿路图的图像质量]。
Digitale Bilddiagnostik Pub Date : 1989-03-01
A Scholz, M Langer, C Zwicker, R Felix
{"title":"[Picture quality of a digital urogram using image enhancement radiography].","authors":"A Scholz,&nbsp;M Langer,&nbsp;C Zwicker,&nbsp;R Felix","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The use of digital image radiography in urographic diagnostics yields a high percentage of images that are useful in diagnosis, even at the present state of technical development which is rapidly improving. Our own results obtained in a prospective study on 75 patients supply proof of such diagnostically useful pointers. Clear improvements in demonstrating the details when employing a 28 cm image amplifier input format in place of the additionally used 40 cm are seen only with the system of the renal calices. However, we found that the 40 cm image amplifier input format proved satisfactory in respect of assessing renal contours, kidney pelvis and ureters as far as image quality was concerned. Enhance image quality can be expected in future from the use of wedge-shaped diaphragms as well as a selective influencing of the automatic exposure (several measurement chambers, weighting factors) and the transfer of monitor screen contents to hard copy without incurring any losses during transfer.</p>","PeriodicalId":77527,"journal":{"name":"Digitale Bilddiagnostik","volume":"9 1","pages":"31-5"},"PeriodicalIF":0.0,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13847765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信