Advances in ophthalmic plastic and reconstructive surgery最新文献

筛选
英文 中文
The myofibroblast and the anophthalmic socket. 肌成纤维细胞和眼窝。
S A Kaltreider
{"title":"The myofibroblast and the anophthalmic socket.","authors":"S A Kaltreider","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>One of the greatest advances in the understanding of wound healing was the identification and characterization of the myofibroblast by Gabbiani in 1971. Since that time this contractile cell has been found in the early stages of wound healing and in many pathologic states. In a recent study, the myofibroblast was found in healing and contracting anophthalmic sockets.</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"9 ","pages":"93-6"},"PeriodicalIF":0.0,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12627219","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Integrated orbital implants. 综合眼眶植入物。
Advances in ophthalmic plastic and reconstructive surgery Pub Date : 1990-12-01 DOI: 10.1097/00002341-199012000-00033
A. Perry
{"title":"Integrated orbital implants.","authors":"A. Perry","doi":"10.1097/00002341-199012000-00033","DOIUrl":"https://doi.org/10.1097/00002341-199012000-00033","url":null,"abstract":"Newer trends in enucleation surgery have included placement of the orbital implant deep within the muscle cone. The use of homologous or autologous tissue to wrap the implant has aided in decreasing extrusion. Newer implant materials show promise in reducing extrusion and in creating an integrated motility implant.","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 1","pages":"75-81"},"PeriodicalIF":0.0,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00002341-199012000-00033","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"61331984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 155
Abnormalities of the palpebral aperture. 睑孔异常。
S L Bosniak
{"title":"Abnormalities of the palpebral aperture.","authors":"S L Bosniak","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The socket surfaces, conjunctival fornices and palpebral aperture are intimately related. Any socket or fornix abnormality will affect the contour and size of the palpebral aperture. Conversely, a cicatricial lid deformity will alter the depth and contour of the conjunctival fornix. Any surgical correction of a lid malposition must calculate the resultant effect on the socket.</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"243-58"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13400356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Empirical impression technique for artificial eye fitting. 人工眼配眼的经验印象技术。
J A LeGrand, M O Hughes
{"title":"Empirical impression technique for artificial eye fitting.","authors":"J A LeGrand,&nbsp;M O Hughes","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Using an impression of the anophthalmic socket to facilitate the design of an artificial eye is common practice today. The Modified Impression technique was described in the American Journal of Ophthalmology, February 1969, by Lee Allen and Howard E. Webster. It is a highly successful method that involves taking an impression of the socket using an impression tray, then making a wax casting of the impression, and final modifications to the anterior aspect of the wax model. A different technique has been in use in our office and elsewhere for more than 15 years, also with a high degree of success. We've dubbed it the \"Empirical/Impression\" method. It involves similar steps to the Modified Impression system, but in different order: first a wax model of the anterior aspect of the eye is designed and modified; second, an impression is made of the socket, using this wax model as an impression tray. The primary advantage of this method is efficiency. It involves one less laboratory procedure, hence making a \"one-day custom eye\" a reality. Although this process can be used in almost any case, the Modified Impression technique may work better for certain highly irregular sockets where \"reading\" the fornices by empirical means may be difficult. Either method requires a highly skilled and experienced fitter to make appropriate modifications to the anterior aspect of the prosthesis.</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"118-25"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13399107","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Enucleation of the eye with implantation of the patient's fat into the cavity. 1917. 将病人的脂肪植入腔内,摘除眼球。1917.
J M Wheeler
{"title":"Enucleation of the eye with implantation of the patient's fat into the cavity. 1917.","authors":"J M Wheeler","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"151-2"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13399112","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Integrated orbital implants. 综合眼眶植入物。
A C Perry
{"title":"Integrated orbital implants.","authors":"A C Perry","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Newer trends in enucleation surgery have included placement of the orbital implant deep within the muscle cone. The use of homologous or autologous tissue to wrap the implant has aided in decreasing extrusion. Newer implant materials show promise in reducing extrusion and in creating an integrated motility implant.</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"75-81"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13328364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Care of the ocular prosthesis. 眼假体的护理。
W R Trawnik
{"title":"Care of the ocular prosthesis.","authors":"W R Trawnik","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The goal of the ocular prosthetic procedure is to return the patient to a normal appearance and lifestyle. Modern eye prostheses can give the patient an excellent physical and cosmetic result. In the final analysis, the success or failure of the long-term use of the prosthesis is dependent on the cooperation of the patient in the care of his ocular prosthesis. It is important for the patient to be aware of and proficient in the care of his prosthesis. Patient education and professional follow-up will ensure the best prosthetic fit, appearance, and health of the anophthalmic socket.</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"146-8"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13399110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Complications of dermis-fat orbital implantation. 真皮脂肪眶植入术的并发症。
S L Bosniak
{"title":"Complications of dermis-fat orbital implantation.","authors":"S L Bosniak","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Primary dermis-fat implantation can be effectively performed in cases without pre-existing systemic vascular disease or orbital burns. Meticulous handling of the graft (using a Goeller trephine and Tenon's capsule traction sutures), filleting Tenon's capsule, and avoiding cautery of the graft bed may minimize graft necrosis and atrophy. Pyogenic granulomas of the conjunctival-graft interface and graft hirsutism are easily managed. Keratinization of the socket, graft wound dehiscence, donor site hematomas, and wound dehiscence are avoided with careful surgical technique. Secondary dermis-fat orbital implantation may add orbital volume and conserve the conjunctival fornices, but may also suffer a slightly increased frequency and amount of graft absorption.</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"170-81"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13399114","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Prosthesis fitting following autogenous dermis-fat orbital implantation: an ocularist's view. 自体真皮-脂肪眼窝植入术后的假体植入:眼科医生的观点。
H P Gougelmann
{"title":"Prosthesis fitting following autogenous dermis-fat orbital implantation: an ocularist's view.","authors":"H P Gougelmann","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"182-3"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13399115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mobility implants: a review. 移动性植入物:综述。
W Danz
{"title":"Mobility implants: a review.","authors":"W Danz","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>We present a brief review of mobility implants, their contribution, and the experiences derived after almost 40 years since the new concepts of full mobility implants were introduced. In early 1940, experiments with a new material for the making of plastic artificial eyes was also being considered for the making of orbital implants. Methyl-methacrylate (MMA) had proven inert and satisfactory for dental products. The Surgeon Generals office of the Armed Services encouraged further research and experimental work in the development of plastic eyes. The success of the new material sponsored the beginning of great expansion with new concepts for orbital implants. Through a period of more than a decade, the design and types of implants went through three stages. First, the buried implant was introduced, then the exposed integrated followed, and the buried integrated subsequently followed. The path of progress was not smooth. Theoretically correct designs and surgical procedures met unexpected practical difficulties for the ophthalmic surgeon, the patient, and the eye maker. Surgical and technical efforts were carefully reviewed to eliminate the problems encountered, only to have further unforeseen complications arise. Infections, extrusions, and migration of the implant were not uncommon. The exposed integrated implant was eventually abandoned. However, there were some extraordinary successes of mobility. A new era introduced fully buried mobility implants that were more successful. However, this procedure also produced some problems, causing infection (or allergy), extrusion, and migration. Tantalum mesh and gauze gave great promise with the inception of their use. Orbital tissue grew into the material in an astonishing way, making it possible to secure the extraocular muscles and tenons.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":76979,"journal":{"name":"Advances in ophthalmic plastic and reconstructive surgery","volume":"8 ","pages":"46-52"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13400361","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信