Medical instrumentation最新文献

筛选
英文 中文
In vitro ultrasonic imaging of flow through prosthetic heart valves. 人工心脏瓣膜血流的体外超声成像。
Medical instrumentation Pub Date : 1987-04-01
G C Gels, H F Stewart, S W Smith
{"title":"In vitro ultrasonic imaging of flow through prosthetic heart valves.","authors":"G C Gels,&nbsp;H F Stewart,&nbsp;S W Smith","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A rapid, inexpensive, portable technique has been developed for the qualitative and semiquantitative evaluation of in vitro flow characteristics through prosthetic heart valves. The technique combines a cardiac pulse duplicator and any diagnostic, linear sequential array, ultrasonic imaging system. The pulse duplicator has been modified to include an acoustically transparent aortic section which contains the prosthetic valve to be evaluated. The acoustically transparent section is fabricated from Rho-c rubber and enables direct flow-imaging for several centimeters on both sides of the prosthesis. Aerated tap water is used as a contrast medium. Forward and reverse flow, laminar flow complex eddy patterns, regurgitation, and jets are easily observed in real time over a wide field of view. Time-exposure photography of sequential images and subsequent off-line calculations enable point-by-point determinations of flow velocities. This work allowed preliminary evaluations of four cardiac valves: Bjork-Shiley, St. Jude, caged disk, and Starr-Edwards.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 2","pages":"66-74"},"PeriodicalIF":0.0,"publicationDate":"1987-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14429930","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Skeletal muscle for heart repair or assistance. 用于心脏修复或辅助的骨骼肌。
Medical instrumentation Pub Date : 1987-04-01
M A Acker, L W Stephenson
{"title":"Skeletal muscle for heart repair or assistance.","authors":"M A Acker,&nbsp;L W Stephenson","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 2","pages":"104-6"},"PeriodicalIF":0.0,"publicationDate":"1987-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14735532","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrosurgical dispersive electrodes heat cutaneous and subcutaneous skin layers. 电外科分散电极加热皮肤和皮下皮肤层。
Medical instrumentation Pub Date : 1987-04-01
J Edrich, C C Cookson
{"title":"Electrosurgical dispersive electrodes heat cutaneous and subcutaneous skin layers.","authors":"J Edrich,&nbsp;C C Cookson","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Electrosurgical return electrodes can produce heating, and occasionally burns, of cutaneous and subcutaneous skin layers. Up to now, only limited aspects of modern, dispersive, polymer electrodes have been studied using infrared thermography and thermocouples. This report presents new results on a quantitative infrared study, and adds the aspects of subcutaneous effects using microwave thermography as a third dimension. In agreement with previous work in infrared thermography, average cutaneous temperature increases observed in a dozen human volunteers were 1.5 degrees C for the normal mode, and 5.7 degrees C at near-fault (with partial contact). The intradermal and/or subcutaneous microwave thermographic images exhibited slightly lower, but still significant temperature elevations which were located at a more leading location, and were more widespread. This significant heating of subcutaneous layers, particularly of the sensitive stratum germinativum, clearly suggests the need for multiple-depth (microwave and infrared) thermography in order to evaluate the thermal performance of dispersive electrosurgical return electrodes.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 2","pages":"81-6"},"PeriodicalIF":0.0,"publicationDate":"1987-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14735535","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
FDA evaluates policy on disposable dialysis device reuse. FDA评估一次性透析装置再利用政策。
Medical instrumentation Pub Date : 1987-04-01
J C Villforth, M J Miller
{"title":"FDA evaluates policy on disposable dialysis device reuse.","authors":"J C Villforth,&nbsp;M J Miller","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 2","pages":"107-8"},"PeriodicalIF":0.0,"publicationDate":"1987-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14735533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Zero stability of disposable and reusable pressure transducers. 一次性和可重复使用压力传感器的零稳定性。
Medical instrumentation Pub Date : 1987-04-01
V L Gordon, J P Welch, D Carley, R Teplick, R S Newbower
{"title":"Zero stability of disposable and reusable pressure transducers.","authors":"V L Gordon,&nbsp;J P Welch,&nbsp;D Carley,&nbsp;R Teplick,&nbsp;R S Newbower","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Zero stability tests were performed on contrasting, commercially available, blood pressure-transducer systems. One system was based on a brand of disposable transducer. The others employed one brand of reusable transducer with and without samples of two different brands of compatible disposable domes. Drift was measured at atmospheric pressure over 3-hr periods. Drifts with the disposable transducers and with the bare reusable transducers were small, ranging from -2 to +2 mm Hg over 3 hr. However, the drifts of the reusable transducers with domes were significantly greater, ranging from -11 mm to +5 mm Hg. The disposable transducers did not drift significantly after the first half hour, although the reusable transducers with domes continued to drift. In addition, one brand of disposable dome produced inaccurate calibrations with the reusable transducer. The methodology of drift measurement and analysis should be practical and useful in other settings and with other brands of transducers. In general, the results indicate that periodic zeroing is still a clinically important procedure, and it is a worthwhile effort prior to treatment decisions based on pressure readings.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 2","pages":"87-91"},"PeriodicalIF":0.0,"publicationDate":"1987-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14735536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The physics of thermal exchange between infants and their environment. 婴儿和环境之间热交换的物理学。
Medical instrumentation Pub Date : 1987-02-01
M H LeBlanc
{"title":"The physics of thermal exchange between infants and their environment.","authors":"M H LeBlanc","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Although much additional work is needed to accurately define the physics of thermal transfer between a baby and the environment, especially with respect to convection and evaporation, it is currently possible to calculate estimates of the quantities in many conditions. These estimates are valuable in predicting the effect various design changes will have on the performance of an incubator or warmer. They also allow us to define what many of the important parameters of an infant are for heat exchange. This brings us closer to designing appropriate infant models for efficiently testing incubator or radiant warmer designs both in the factory and in medical equipment evaluation facilities and perhaps in government regulatory facilities.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 1","pages":"11-5"},"PeriodicalIF":0.0,"publicationDate":"1987-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14734652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The thermophysiology of the newborn infant. 新生婴儿的热生理学。
Medical instrumentation Pub Date : 1987-02-01
R A Darnall
{"title":"The thermophysiology of the newborn infant.","authors":"R A Darnall","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The preterm newborn, although a homeotherm in the true sense of the word, has increased heat and water losses when compared to the adult and these large losses necessitate providing a thermal environment which can allow a minimal resting metabolic rate. The physician who cares for newborn infants must direct special attention to the maintenance of \"normal\" body temperature of the low-birth-weight infant, whose survival may depend on such careful management. However, the physiology of temperature control is important for almost every aspect of the management of these infants; the immediate adaptation to extrauterine life, requirements for oxygen and calories, growth and development, and the diagnosis of infection. An understanding of these interrelated areas is highly relevant to the successful management of a wide variety of clinical problems in the newborn period.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 1","pages":"16-22"},"PeriodicalIF":0.0,"publicationDate":"1987-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14734653","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Future directions for device design and infant management. 器械设计和婴儿管理的未来方向。
Medical instrumentation Pub Date : 1987-02-01
P H Perlstein
{"title":"Future directions for device design and infant management.","authors":"P H Perlstein","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 1","pages":"36-41"},"PeriodicalIF":0.0,"publicationDate":"1987-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14735529","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of biomedical equipment operator's manual. 生物医学设备操作人员手册的编写。
Medical instrumentation Pub Date : 1987-02-01
M J Shaffer, D Sim
{"title":"Development of biomedical equipment operator's manual.","authors":"M J Shaffer,&nbsp;D Sim","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 1","pages":"44-6"},"PeriodicalIF":0.0,"publicationDate":"1987-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14735531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Impact of technology on environmental therapeutic device design. 技术对环境治疗装置设计的影响。
Medical instrumentation Pub Date : 1987-02-01
M H Mackin
{"title":"Impact of technology on environmental therapeutic device design.","authors":"M H Mackin","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"21 1","pages":"33-5"},"PeriodicalIF":0.0,"publicationDate":"1987-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14734656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书