Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition最新文献
Komlan Payne, Aditya A Bhosale, Yunkun Zhao, Xiaoliang Zhang
{"title":"High impedance quadrature receivers array for magnetic resonance skin imaging at 7T.","authors":"Komlan Payne, Aditya A Bhosale, Yunkun Zhao, Xiaoliang Zhang","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438993/pdf/nihms-1925022.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10049472","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Xiaoliang Zhang, Matt Waks, Lance DelaBarre, Komlan Payne, Kamil Ugurbil, Gregor Adriany
{"title":"Design and Test of a Flexible Two-row CTL Array and Its Detunable Resonant Elements for 10.5T MR Imaging.","authors":"Xiaoliang Zhang, Matt Waks, Lance DelaBarre, Komlan Payne, Kamil Ugurbil, Gregor Adriany","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10948114/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140159685","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"DOuble tuned and DOuble matched large-size loop coil (DODO) design and evaluation for <sup>17</sup>O MRSI and <sup>1</sup>H MRI application at 7T.","authors":"Xin Li, Guangle Zhang, Wei Zhu, Xiaoliang Zhang, Xiao-Hong Zhu, Wei Chen","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440072/pdf/nihms-1925036.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10049468","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Accelerating MRI Using Vision Transformer with Unpaired Unsupervised Training.","authors":"Peizhou Huang, Hongyu Li, Ruiying Liu, Xiaoliang Zhang, Xiaojuan Li, Dong Liang, Leslie Ying","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440071/pdf/nihms-1925040.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10049463","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Caroline Magnain, Robin Haynes, Jean Augustinack, Hannah Kinney, Lilla Zollei
{"title":"Integration of imaging measurements at micro-, meso and macro-scale of the caudal medulla on a postmortem infant subject.","authors":"Caroline Magnain, Robin Haynes, Jean Augustinack, Hannah Kinney, Lilla Zollei","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"2023 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10964281/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140295499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigating the Optimal Number of Channels in an Array System for Human Head Imaging at 7T.","authors":"Aditya Ashok Bhosale, Leslie Ying, Xiaoliang Zhang","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440070/pdf/nihms-1924999.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10106007","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ikbeom Jang, Malte Hoffmann, Nalini Singh, Yael Balbastre, Lina Chen, Marcio Aloisio Bezerra Cavalcanti Rockenbach, Adrian Dalca, Iman Aganj, Jayashree Kalpathy-Cramer, Bruce Fischl, Robert Frost
{"title":"Clinical evaluation of k-space correlation informed motion artifact detection in segmented multi-slice MRI.","authors":"Ikbeom Jang, Malte Hoffmann, Nalini Singh, Yael Balbastre, Lina Chen, Marcio Aloisio Bezerra Cavalcanti Rockenbach, Adrian Dalca, Iman Aganj, Jayashree Kalpathy-Cramer, Bruce Fischl, Robert Frost","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Motion artifacts can negatively impact diagnosis, patient experience, and radiology workflow especially when a patient recall is required. Detecting motion artifacts while the patient is still in the scanner could potentially improve workflow and reduce costs by enabling immediate corrective action. We demonstrate in a clinical k-space dataset that using cross-correlation between adjacent phase-encoding lines can detect motion artifacts directly from raw k-space in multi-shot multi-slice scans. We train a split-attention residual network to examine the performance in predicting motion artifact severity. The network is trained on simulated data and tested on real clinical data.</p>","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"2023 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10414784/pdf/nihms-1871408.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9987854","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Lumped inductors in RF resonators decrease the B1 fields in samples at ultrahigh fields.","authors":"Yunkun Zhao, Xiaoliang Zhang","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438995/pdf/nihms-1924973.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10106001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of conductor width on coil array coupling.","authors":"Yunkun Zhao, Xiaoliang Zhang","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438997/pdf/nihms-1924967.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10106002","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High permittivity material for catheter tracking in interventional imaging.","authors":"Yunkun Zhao, Xiaoliang Zhang","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":74549,"journal":{"name":"Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition","volume":"31 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440077/pdf/nihms-1924976.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10106004","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}