2019 54th International Universities Power Engineering Conference (UPEC)最新文献

筛选
英文 中文
Monitoring of Digital Substations Using DDS 数字变电站的DDS监控
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893541
I. Shin, D. Choi, Hoon Choi
{"title":"Monitoring of Digital Substations Using DDS","authors":"I. Shin, D. Choi, Hoon Choi","doi":"10.1109/UPEC.2019.8893541","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893541","url":null,"abstract":"Building and managing intelligent digital substations is receiving much attention, worldwide. This paper proposes the collection of digital substation monitoring information by using DDS, which is a publication/subscription-based real-time communication protocol. The paper shows a network structure of digital substations for collecting monitoring information from each facility by applying DDS. The network structure has multiple search domains that separate power facilities in substations according to their functions. It also presents an object-to-object conversion relationship and DDS object identification system for changing existing IEC 61850 based systems to DDS-based systems. Applying the DDS to digital substations enables dynamic recognition/identification through the DDS discovery protocol and enables collecting only desired monitoring information. We configured an experimental network environment to measure the elapsed times for dynamic recognition and identification of an IED. The experimental network has two different domains. The experiment showed that real-time monitoring is possible. The HMI node can detect in less than 0.7sec when additional IEDs are installed in the substation. This method can be applied to a system where configuration of a power facility dynamically changes, such as a micro grid.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"254 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76533770","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Simulation concept of a virtual power plant based on real-time data acquisition 基于实时数据采集的虚拟电厂仿真概念
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893565
David-Cătălin Urcan, D. Bică
{"title":"Simulation concept of a virtual power plant based on real-time data acquisition","authors":"David-Cătălin Urcan, D. Bică","doi":"10.1109/UPEC.2019.8893565","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893565","url":null,"abstract":"The paper presents a comprehensive survey on the virtual power plant (VPP) concept. The survey covers the virtual power plant definitions, components, frame work and highlights the different techniques that can be used for VPP operation optimization. At the end of the works will be presented a virtual power plant infrastructure available on a web interface where it will be possible to control a virtual micro-grid that has acquire data from virtual smart meters which provide several load profiles for load consumption and distributed generation points.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"150 1","pages":"1-4"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77376714","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Generation Companies Agent-Based Modelling: Application to the Colombian Day-Ahead Market 发电公司基于代理的模型:在哥伦比亚日前市场的应用
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893518
Gianluca Rimini, V. Ilea, C. Bovo
{"title":"Generation Companies Agent-Based Modelling: Application to the Colombian Day-Ahead Market","authors":"Gianluca Rimini, V. Ilea, C. Bovo","doi":"10.1109/UPEC.2019.8893518","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893518","url":null,"abstract":"Several Agent-Based Modelling platforms specific for the energy market simulations have been implemented in recent years. However, the methodology to manage the individual plants under the same generation company is not well investigated. This represents a very critical aspect for oligopolistic markets. The aim of this work is to develop an Agent-Based Modelling platform that recreates the coordinated management of different plants of the same generation company with focus on the prevalence of the hydropower plants in the generation park. The model will be used to analyses the Colombian Day-Ahead Electricity market.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"37 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80107669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PWM and FCS-MPC in a Single Phase Converter with L Filter: An Extensive Comparison 带L滤波器的单相变换器中的PWM和FCS-MPC的广泛比较
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893524
Evangelos E. Pompodakis, C. Demoulias
{"title":"PWM and FCS-MPC in a Single Phase Converter with L Filter: An Extensive Comparison","authors":"Evangelos E. Pompodakis, C. Demoulias","doi":"10.1109/UPEC.2019.8893524","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893524","url":null,"abstract":"In this paper, an extensive comparison between the Phase Shifted PWM (PS-PWM) and the Finite Control Set Model Predictive Control (FCS-MPC) method is attempted. Particular emphasis is placed on the influence of proportional gain to the efficiency of PS-PWM. Furthermore, an analytical approach which facilitates the calculation of optimal proportional and integral gains of PS-PWM was developed. In addition, a delay compensation method applied in FCS-MPC and PS-PWM is proposed. Simulation results are provided to test the behavior of both modulation strategies considering several operational aspects both in steady state and in transient operation.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"78 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78860918","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Criteria for evaluating the technical universities of the world using Forbes rating 使用福布斯排名评估世界技术大学的标准
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893600
S. V. Levinzon, Natalia V. Tsarkova
{"title":"Criteria for evaluating the technical universities of the world using Forbes rating","authors":"S. V. Levinzon, Natalia V. Tsarkova","doi":"10.1109/UPEC.2019.8893600","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893600","url":null,"abstract":"the analysis of quantitative and quality indicators of ratings of technical and electrotechnical universities of the world by the international, national and private criteria is considered and made Forbes rating . The similar analysis will give the chance to be guided at choice of profession taking into account many factors.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"90 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82303149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fuzzy Logic Applied to Impact Assessment of Short-Duration RMS Voltage Variation 模糊逻辑在短时均方根电压变化影响评价中的应用
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893630
L. D. da Costa, D. da Silva Gazzana, R. Leborgne
{"title":"Fuzzy Logic Applied to Impact Assessment of Short-Duration RMS Voltage Variation","authors":"L. D. da Costa, D. da Silva Gazzana, R. Leborgne","doi":"10.1109/UPEC.2019.8893630","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893630","url":null,"abstract":"This paper presents a proposal of impact assessment of short-duration rms voltage variations using fuzzy logic. The index IF (Impact Factor) of the Brazilian power quality regulation standard is the evaluation parameter. The fuzzy logic is used to represent the vagueness in the disturbance magnitude and duration measures. The method is used with computationally generated power quality signals. According to the results, the fuzzy assessment seems to be a good method to represent the impact of the disturbances at a consumer taking into account the uncertainties in the measures of voltage magnitude and duration.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"29 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82307682","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Impact on Distribution System Protection with the Integration of EG on the Distribution Network 配电网集成EG对配电网保护的影响
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893563
Jane Courtney, Aaron McDonnell
{"title":"Impact on Distribution System Protection with the Integration of EG on the Distribution Network","authors":"Jane Courtney, Aaron McDonnell","doi":"10.1109/UPEC.2019.8893563","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893563","url":null,"abstract":"A significant increase in EG connections on the distribution network over the past decade in Ireland has presented challenges to the Distribution System Operator (DSO). The connection of EG can cause co-ordination of Distance protection to be altered and has resulted in variations in short circuit levels. Multidirectional power flow has been introduced into a Distribution system that was not designed for the direction change in current flow. The impact of connecting EG to a typical 38 kV Distribution Network was demonstrated as part of this study. Increasing fault levels and protection co-ordination selectivity problems were identified when the network was fed as a closed network. The increase in short circuit fault levels was evident when the fault contribution from the EG was considered. This increase in short circuit fault current could be a concern if EG is installed in an area where the maximum current rating of the switchgear could be exceeded. The co-ordination of Distance protection IEDs were also affected when EG was connected. Case studies on a typical Distribution Network were presented as part of this study. The impact that EG can have on the short circuit fault levels and the co-ordination of Distance protection when the network is feeding as a closed loop network was identified. When incorporating EG to a typical 38 kV Distribution Network, considerations must be made to ensure that the connection of the EG does not inhibit the performance of the overall protection system. A protection review of the network is required before any EG is connected. The issues identified the miscoordination of Distance protection IEDs. A revision of current IED settings in the vicinity of the installed EG and the addition of duplicate protection IEDs may be required.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"23 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86952307","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Implications for the Rate of Change of Frequency on an Isolated Power System 对隔离电力系统频率变化率的影响
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893446
Michael O’Donovan, Eoghan O'Callaghan, N. Barry, J. Connell
{"title":"Implications for the Rate of Change of Frequency on an Isolated Power System","authors":"Michael O’Donovan, Eoghan O'Callaghan, N. Barry, J. Connell","doi":"10.1109/UPEC.2019.8893446","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893446","url":null,"abstract":"The Irish power system illustrates today the main issues which many power systems need to address from an operations and control viewpoint, i.e. the advent of stochastic generation in the form of wind, solar and wave energy, and the change in the constitution of the electrical loads. This paper examines RoCoF standards and protection and presents a practical example of testing the RoCoF capabilities of on-load generators in a live pumped storage hydro station. The technical reasons and mathematical basis for carrying out these tests are included to provide context to the example described. Results for each test are provided with illustrative plots for reference.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"89 1","pages":"1-6"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89128128","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Single-terminal Fault Location Algorithm for Electrical Lines 电力线路单端故障定位算法
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893618
Marian Dragomir, Anamaria Iamandi, A. Rusu, Marian Atănăsoaei, A. Dragomir, M. Adam, M. Andrusca
{"title":"Single-terminal Fault Location Algorithm for Electrical Lines","authors":"Marian Dragomir, Anamaria Iamandi, A. Rusu, Marian Atănăsoaei, A. Dragomir, M. Adam, M. Andrusca","doi":"10.1109/UPEC.2019.8893618","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893618","url":null,"abstract":"Precise fault location can minimize the outage time of a faulted line with benefits in power grid stability and safety. Impedance-based fault location algorithms are commonly used in fault locators, due to their simplicity. In particular, single-terminal impedance-based algorithms represent a standard feature implemented in digital relays, but they are affected by the different source of errors. In the paper, there is presented a fault location algorithm which uses only the local voltage and current phasors and the parameters of the line to estimate the distance to the fault. The algorithm was tested using simulated fault signals as well as real fault registered signals from the field. The output results were compared with the output results of two established fault location algorithms and they reveal the effectiveness and robustness of the proposed algorithm.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"65 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85005197","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Location of Disk Space Variations in Transformer Winding using Convolutional Neural Networks 基于卷积神经网络的变压器绕组磁盘空间变化定位
2019 54th International Universities Power Engineering Conference (UPEC) Pub Date : 2019-09-01 DOI: 10.1109/UPEC.2019.8893596
Arash Moradzadeh, K. Pourhossein
{"title":"Location of Disk Space Variations in Transformer Winding using Convolutional Neural Networks","authors":"Arash Moradzadeh, K. Pourhossein","doi":"10.1109/UPEC.2019.8893596","DOIUrl":"https://doi.org/10.1109/UPEC.2019.8893596","url":null,"abstract":"In this paper, disk space variations (DSV) as one of common transformer winding defects, has been practically applied to a transformer winding in some specific locations and with various extents. To locate DSV faults, Convolutional neural networks (CNN) has been applied to frequency response traces of the tested winding. It has been presented that the proposed method has accurate fault location capability. Convolutional Neural Networks was utilized to extract important features from frequency response traces to detect DSV location in transformer winding.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"2 1","pages":"1-5"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86852650","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信