2012 IEEE Energy Conversion Congress and Exposition (ECCE)最新文献

筛选
英文 中文
Transient load sharing between inverters and synchronous generators in islanded microgrids 孤岛微电网逆变器与同步发电机的暂态负荷分担
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342533
A. Paquette, M. Reno, R. Harley, D. Divan
{"title":"Transient load sharing between inverters and synchronous generators in islanded microgrids","authors":"A. Paquette, M. Reno, R. Harley, D. Divan","doi":"10.1109/ECCE.2012.6342533","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342533","url":null,"abstract":"When inverters in voltage control mode are paired with synchronous generators they exhibit poor transient load sharing in islanded operation. The inverter initially picks up the majority of every load step, and the generator's output slowly increases until they reach their steady state load sharing given by droop settings. This excessive transient power output from the inverter constrains its rating compared to the largest anticipated load step, and could negatively impact battery life in battery energy storage inverters. This paper examines the transient load sharing characteristics between synchronous generators and inverters in voltage control, i.e. grid-supporting-grid-forming control, and investigates methods to improve it. An equivalent circuit is proposed to describe the initial power sharing ratio, and the effects of increased inverter droop slope and increased governor integral gain are investigated. An inverter control strategy of emulating a synchronous generator is shown to provide good transient load sharing. Validation is provided by simulation and experimental results for real and reactive loads.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82854256","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 31
Thermal design considerations for 12kV SiC n-IGBT based 3L NPC converter 12kV SiC n-IGBT型3L NPC变换器的热设计考虑
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342445
G. Karimi-Moghaddam, R. Gould, S. Madhusoodhanan, K. Hatua, S. Bhattacharya, S. Leslie, S. Ryu, M. Das, A. Agarwal, D. Grider
{"title":"Thermal design considerations for 12kV SiC n-IGBT based 3L NPC converter","authors":"G. Karimi-Moghaddam, R. Gould, S. Madhusoodhanan, K. Hatua, S. Bhattacharya, S. Leslie, S. Ryu, M. Das, A. Agarwal, D. Grider","doi":"10.1109/ECCE.2012.6342445","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342445","url":null,"abstract":"Transformer less Intelligent Power Substation (TIPS) is a solid state replacement for the conventional bulky distribution transformers used for 13.8kV and 480V grid interconnectivity. A 100kVA 3L NPC converter is being built using 12kV SiC n-IGBT for the high voltage grid interface. In this paper, detailed thermal behavior of this converter is studied for optimum thermal design. The thermal profile at the die level at different power factor of operation is studied. This study helps the optimum component placement in the converter. Also it shows that the operating modes of the converter play a key role in optimum thermal design.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90719769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
28V bus solar array regulator based on converters with transformer and self-driven Synchronous Rectification 基于变压器变换器和自驱动同步整流的28V母线太阳能阵列稳压器
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342697
A. Fernández, H. Carbonnier, O. Mourra, F. Tonicello
{"title":"28V bus solar array regulator based on converters with transformer and self-driven Synchronous Rectification","authors":"A. Fernández, H. Carbonnier, O. Mourra, F. Tonicello","doi":"10.1109/ECCE.2012.6342697","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342697","url":null,"abstract":"Satellite power systems are generally based on non isolated topologies. Simplicity, robustness and high efficiency are the key parameters and hence, these topologies are the leaders. However, extra switches are needed for protection; the design of the MOSFET drivers is not so simple if a full excursion from 0% to 100% is needed; the design has to be changed accordingly with the design of the solar array. An alternative concept is proposed in this paper and is based on topologies with transformer. Less switches are needed for protection and just by changing the transformer turns ratio, the converter can accommodate different designs of solar arrays. The main drawback is the efficiency, which is a key player in the space power systems. To overcome this, a Synchronous Rectification system is proposed in order to boost the efficiency with respect to the diode version counterpart. A new system based on the output inductor waveforms is also proposed in this paper.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90736430","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Time optimal and loss minimizing deadbeat-direct torque and flux control for interior permanent magnet synchronous machines 时间优化和损耗最小化——内部永磁同步电机的直接转矩和磁通控制
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342396
Jae Suk Lee, Robert D. Lorenz, M. A. Valenzuela
{"title":"Time optimal and loss minimizing deadbeat-direct torque and flux control for interior permanent magnet synchronous machines","authors":"Jae Suk Lee, Robert D. Lorenz, M. A. Valenzuela","doi":"10.1109/ECCE.2012.6342396","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342396","url":null,"abstract":"This paper presents time optimal control of an interior permanent magnet synchronous machine (IPMSM) in voltage- and current- limited conditions using deadbeat-direct torque and flux control (DB-DTFC). A commanded air-gap torque and flux can be achieved by the end of each PWM period using DB-DTFC. However, it may take several PWM periods to achieve a desired torque that is physically infeasible in one step when operating near the voltage limit. The large torque command can be shaped as a feasible trajectory so that the deadbeat torque and flux is achieved for every sample time instant (switching period) along the trajectory. In this paper, the feasible trajectory is dynamically optimized to achieve a large torque command in the shortest time during voltage- and current-limited operation. Loss minimizing stator flux linkage is used during steady state operation to reduce computational complexity of the dynamic optimization and to operate the IPMSM at the loss minimizing condition. The voltage- and current-limited operation of IPMSM drives is evaluated in both simulation and experiment in this paper.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90996842","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Impact of gate driver signal on static losses for a SiC switch built with Normally-Off JFETs and a Schottky diode 栅极驱动信号对正常关断jfet和肖特基二极管构成的SiC开关静态损耗的影响
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342636
X. Fonteneau, F. Morel, H. Morel, P. Lahaye, E. Rondon-Pinilla
{"title":"Impact of gate driver signal on static losses for a SiC switch built with Normally-Off JFETs and a Schottky diode","authors":"X. Fonteneau, F. Morel, H. Morel, P. Lahaye, E. Rondon-Pinilla","doi":"10.1109/ECCE.2012.6342636","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342636","url":null,"abstract":"This document shows the behaviour of a SiC switch built with Normally-Off JFETs and a Schottky diode when the JFETs are controlled with a constant gate-to-source voltage or with a constant gate current. The JFETs are used in a direct and reverse conduction. The goal of this study is to determine a gate driver signal that minimizes static losses in the switch in spite of temperature variations. Two switches are tested: the first one is built with one JFET and one diode, the second one is built with four JFETs and one diode. It has been shown that in both cases, when reverse conduction is used, a current controlled gate driver leads to lower static losses.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89690614","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Power management of photovoltaic and fuel cell hybrid system for a constant-power-demand DC supply bus using complementary energy dispatch 基于互补能量调度的恒功率-需求直流母线光伏与燃料电池混合系统的电源管理
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342213
G. Hsieh, Chengxin Su, Hung-I Hsieh
{"title":"Power management of photovoltaic and fuel cell hybrid system for a constant-power-demand DC supply bus using complementary energy dispatch","authors":"G. Hsieh, Chengxin Su, Hung-I Hsieh","doi":"10.1109/ECCE.2012.6342213","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342213","url":null,"abstract":"This paper presents a power management for a photovoltaic (PV) and fuel cell (FC) hybrid system that complementarily dispatches energies into a constant-power-demand DC bus (DCB) through a boost current (BCC) and Z-source voltage (ZSVC) converters. A novel power-increment-aided maximum power point tracking (PI-INC MPPT) with a duty detection is used to guide the PV-BCC to pump PV energy fast and accurate as well as provide a burst regulation to FC-ZSVC for quick energy dispatch. Accordingly, the feed-in PV energy is priority for hybrid in consideration of energy treasuring. An experiment presents the mutual energy dispatch behavior between PV and FC for a down-scale constant 250-W DCB under different solar insolation tests.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89249728","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Matrix transformers for renewable energy integration 用于可再生能源集成的矩阵变压器
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342602
Jiyao Wang, Yehui Han
{"title":"Matrix transformers for renewable energy integration","authors":"Jiyao Wang, Yehui Han","doi":"10.1109/ECCE.2012.6342602","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342602","url":null,"abstract":"This paper investigates the concept of using matrix transformers to achieve renewable energy integration. Matrix transformers can provide great design flexibility because they can be compatible with a variety of renewable energy sources as well as energy storage devices. Several key techniques raised by this concept are illustrated, and a high efficiency multiple-input and single output converter was designed to show how to use matrix transformers. Simulation and experimental results are presented that validate the approach presented in this paper.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89386530","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Fault diagnoses for the Dc filters of power electronic converters 电力电子变流器直流滤波器的故障诊断
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342451
T. Kamel, C. Diduch, Y. Bilestkiy, Liuchen Chang
{"title":"Fault diagnoses for the Dc filters of power electronic converters","authors":"T. Kamel, C. Diduch, Y. Bilestkiy, Liuchen Chang","doi":"10.1109/ECCE.2012.6342451","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342451","url":null,"abstract":"DC filters are responsible for more than half of the failures in electric power converters. One approach to improving the reliability, performance and maintainability is to include failure diagnosis logic within the power converter. DC bus capacitor failures may be classified as gradual faults caused by capacitor aging and sudden faults which may take the form of breakdown faults resulting from a blown capacitor fuse, and open circuit O-C faults. This paper presents new methods to detect and isolate failures in the DC filters of power converters caused by capacitor aging and O-C faults.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86580967","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Mitigation of harmonics of DFIGs in DC-microgrids 直流微电网DFIGs谐波的抑制
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342574
F. Wei, D. Vilathgamuwa, S. S. Choi
{"title":"Mitigation of harmonics of DFIGs in DC-microgrids","authors":"F. Wei, D. Vilathgamuwa, S. S. Choi","doi":"10.1109/ECCE.2012.6342574","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342574","url":null,"abstract":"During the last few years, there has been an increased attention paid on the developments of DC microgrids (DCMGs) and their applications. For economical and more flexible wind power generation, doubly fed induction generator (DFIG) is regarded as a most commonly used generator in wind farms. This paper presents a configuration and operation method for a DCMG connected with DFIGs, in which the controller of the DFIG is designed for maximum power point tracking (MPPT). The generation of harmonics and their effects on the generator in this configuration are analyzed and a harmonic compensation method is proposed. Furthermore, the simulation results are presented to show that the DFIG can be operated effectively in DCMGs and harmonic currents can be reduced.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87588809","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Dynamic modeling of double cage induction machines for diagnosis of rotor faults 双保持架感应电机转子故障诊断的动力学建模
2012 IEEE Energy Conversion Congress and Exposition (ECCE) Pub Date : 2012-11-12 DOI: 10.1109/ECCE.2012.6342666
E. Lorenzani, A. Salati, C. Bianchini, F. Immovilli, A. Bellini, S. Lee, J. Yoo, C. Kwon
{"title":"Dynamic modeling of double cage induction machines for diagnosis of rotor faults","authors":"E. Lorenzani, A. Salati, C. Bianchini, F. Immovilli, A. Bellini, S. Lee, J. Yoo, C. Kwon","doi":"10.1109/ECCE.2012.6342666","DOIUrl":"https://doi.org/10.1109/ECCE.2012.6342666","url":null,"abstract":"Double cage induction motors are typically employed in applications that require high starting torque for frequent, loaded starts. This makes the starting (outer) cage susceptible to fatigue failure since it must withstand the large thermo-mechanical stress associated with the high starting current and long acceleration time. Conventional FFT-based spectrum analysis techniques are insensitive to outer cage faults due to the small outer cage current under steady state operation, and the fault indicators and thresholds applied to single cage rotors cannot be used. Therefore, there is a strong industrial need for research and development of analysis techniques and advanced fault detection algorithms for double cage machines. However, there are only a few publications that investigate double cage rotor faults. In this paper, a dynamic model for rotor cage faults in double cage motors, which is the first step towards double cage rotor fault research, is derived. A 7.5 Hp separate end ring fabricated copper double cage rotor is built for experimental verification of the proposed fault model (copper inner cage/brass outer cage). The tests performed under startup and steady state operation show that the proposed fault model can provide sufficient accuracy and can be used as the basis for interpretation of FFT results and development of advanced fault detection algorithms.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88004977","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信