2007 IEEE Ultrasonics Symposium Proceedings最新文献

筛选
英文 中文
P2D-2 Quantitative Estimation of Ultrasonic Multiple Access Method Based on M-Sequence Code 基于m序列码的超声多址P2D-2定量估计
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.396
Yong Wang, T. Siginouchi, M. Hashimoto, H. Hachiya
{"title":"P2D-2 Quantitative Estimation of Ultrasonic Multiple Access Method Based on M-Sequence Code","authors":"Yong Wang, T. Siginouchi, M. Hashimoto, H. Hachiya","doi":"10.1109/ULTSYM.2007.396","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.396","url":null,"abstract":"Recently, we have proposed an ultrasonic multiple access method based on the spectrum spread technology using M-sequence codes. However, its effect depends on the preset threshold level. In this paper, we consider a novel quantitative estimation method using the normalized cross-correlation function between two microphones. Using this quantitative estimation method, we investigate the effect of the preset level and show the optimal value of the preset threshold.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"13 1","pages":"1575-1578"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86668832","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
4C-3 Limited-Angle Spatial Compound Imaging of Skin with High-Frequency Ultrasound (20 MHz) 4C-3高频超声皮肤有限角度空间复合成像(20mhz)
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.71
M. Vogt, H. Ermert
{"title":"4C-3 Limited-Angle Spatial Compound Imaging of Skin with High-Frequency Ultrasound (20 MHz)","authors":"M. Vogt, H. Ermert","doi":"10.1109/ULTSYM.2007.71","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.71","url":null,"abstract":"Ultrasound spatial compounding has been proven to successfully improve the image contrast, to achieve a more isotropic resolution and to reduce imaging artifacts in comparison with conventional B-mode imaging. For high- frequency ultrasound (HFUS) imaging of skin, usually linear scans only are performed perpendicularly to the axial direction of sound propagation. In this paper the potential of HFUS limited- angle spatial compounding for skin imaging is evaluated. We have implemented a new 20 MHz ultrasound system for limited- angle (up to plusmn40deg) spatial compound imaging. A sophisticated scanner was designed for high-resolution imaging with a spherically focused single-element transducer. The influence of unknown parameters of the system is eliminated by calibration measurements on a wire phantom. The imaging properties of the implemented system were assessed by means of phantom and in vivo measurements. A ray-tracing method for the compensation of artifacts, which are caused by refraction at the skin surface, is proposed and evaluated.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"41 3 1","pages":"240-243"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86955789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
9B-2 Microbubble Interactions at High Mechanical Index: Ultrasound Stimulated Behaviour of SonoVue from Optically Predefined 'Stand-Off' Positions 9B-2微泡在高机械指数下的相互作用:超声刺激下SonoVue从光学预定义的“对峙”位置的行为
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.195
J. M. Burns, P. Prentice, P. Campbell
{"title":"9B-2 Microbubble Interactions at High Mechanical Index: Ultrasound Stimulated Behaviour of SonoVue from Optically Predefined 'Stand-Off' Positions","authors":"J. M. Burns, P. Prentice, P. Campbell","doi":"10.1109/ULTSYM.2007.195","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.195","url":null,"abstract":"Introduction of a temporally periodic pressure field \u0000within a fluid can induce forced oscillations to bubbles present \u0000therein. The resultant [radial] bubble dynamics are a complex \u0000function of several parameters, including the driving pressure \u0000amplitude, and proximity to nearby boundaries, such as vessel \u0000walls, or indeed, other bubbles. Recently, experimentation \u0000gauged towards the development of a quantitative understanding \u0000of [acoustically] driven bubbles of micrometer dimensions, \u0000especially when close to boundaries, has become a challenge of \u0000heightened academic and industrial interest. In pursuit of this, \u0000the present authors pioneered a new approach to such \u0000measurements that exploits optical trapping to locate microbubbles \u0000at prescribed displacements from a boundary [1,2]. Here, \u0000we extend our previous method and report the first \u0000comprehensive study that has observed the dynamical behavior \u0000of isolated single micro-bubbles (the commercially available \u0000ultrasound contrast agent: SonoVue) that had been optically \u0000trapped over a range of well-defined displacements from a rigid \u0000boundary. All of the measurements were conducted at a \u0000mechanical index (MI) > 3. We noted a distinct variance in \u0000micro-bubble behavior across all quiescent radii and stand-off \u0000parameter, and also correlated bubble outcome statistics with \u0000measured radial dynamics. Finally, we suggest that the procedure \u0000outlined can be exploited to design ‘next-generation’ microbubbles \u0000with specific response characteristics.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"14 1","pages":"761-764"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88493608","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
12E-4 Low Phase Noise, Low Power Consuming 3.7 GHz Oscillator Based on High-Overtone Bulk Acoustic Resonator 基于高泛音本体谐振器的12E-4低相位噪声、低功耗3.7 GHz振荡器
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.293
Hongyu Yu, Chuang-yuan Lee, W. Pang, Hao F. Zhang, E. S. Kim
{"title":"12E-4 Low Phase Noise, Low Power Consuming 3.7 GHz Oscillator Based on High-Overtone Bulk Acoustic Resonator","authors":"Hongyu Yu, Chuang-yuan Lee, W. Pang, Hao F. Zhang, E. S. Kim","doi":"10.1109/ULTSYM.2007.293","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.293","url":null,"abstract":"This paper describes the oscillator based on high- overtone bulk acoustic resonator (HBAR) at 3.7 GHz for chip scale atomic clock (CSAC) application. The HBAR is built on a 400 mum thick sapphire with Al/ZnO/Al sandwich layers having thicknesses 0.1 mum/0.88 mum/0.1 mum, which ensures the best acoustic coupling and highest Q (above 19,000) at around 3.7 GHz. The oscillators have been designed, fabricated and measured to have very low phase noise and low power consumption. The oscillator when measured with agilent 4448 spectrum analyzer is measured to oscillate at 3.677 GHz with output signal power of -15 dBm and phase noise of -108 dBc/Hz at 10 kHz offset and -125 dBc/Hz @100 kHz offset, respectively, while consuming only 6.21 mW.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"10 1","pages":"1160-1163"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90669787","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
P5K-3 Novel Thick Film Transducers for High Frequency Ultrasonography 新型高频超声厚膜换能器P5K-3
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.603
R. Lou-Meller, W. Wolny, E. Ringgaard, A. Nowicki, M. Lewandowski, W. Secomski
{"title":"P5K-3 Novel Thick Film Transducers for High Frequency Ultrasonography","authors":"R. Lou-Meller, W. Wolny, E. Ringgaard, A. Nowicki, M. Lewandowski, W. Secomski","doi":"10.1109/ULTSYM.2007.603","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.603","url":null,"abstract":"New types of thick-film transducers (19 to 37 MHz), with integrated highly attenuating ceramic backing formed of porous PZT material and shaped to the required ROC, were developed. For this project, focused transducers (focal depth 8.8 mm) with two different compositions, based on Ferroperm Pz24 (InSensor TF2400) and Pz26 (In Sensor TF2100), with different dielectric constant were fabricated. The transducers were carefully measured, then electrically and acoustically matched to the acoustical impedance of tissue and next mounted in a mechanical wobbling imaging probe. The transducers were excited with Golay coded sequences at 35 MHz. Introducing the coded excitation allowed replacing the short- burst transmission at 20 MHz with the same peak amplitude pressure, but with almost double center frequency, resulting in considerably better axial resolution. The important factor for coded transmission/reception is the matching of the transducer bandwidth with the one of the coded signal. The thick films exhibited at least 30% bandwidth broadening comparing to the standard Pz27 transducer, resulting in an increase in matching filtering output by a factor of 1.4 - 1.5 and finally resulting in a SNR gain of the same order. Examples of skin scans obtained with the new thick-film transducers are presented. Further improvement of the transducer performance is demonstrated through optimizing the electrical impedance of the HF transducer. This is obtained by using a thick-film component prepared from a lower dielectric constant material, whilst the electromechanical coupling is maintained at approx. 50%.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"65 1","pages":"2397-2400"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91084726","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
P4M-9 Reduction of Crosstalk in CMUT Arrays by Introducing Double Periodicities 引入双周期对CMUT阵列串扰的P4M-9抑制
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.542
S. Berg, A. Rønnekleiv
{"title":"P4M-9 Reduction of Crosstalk in CMUT Arrays by Introducing Double Periodicities","authors":"S. Berg, A. Rønnekleiv","doi":"10.1109/ULTSYM.2007.542","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.542","url":null,"abstract":"Capacitive micromachined ultrasound transducers (CMUTs) promise high transducer performance for several ultrasound applications. When making a focused ultrasound image with a 90 degree image sector we need a large number of individual elements. In off-axis beam steering neighbor elements operate at different phase. This leads to unwanted acoustic effects caused by the interaction with the fluid medium outside the array. We see high-Q resonances close to the center frequency of the array at off-axis angles, which we want to reduce. The present paper gives one approach to this. The introduction of a double periodicity, with a larger distance between elements than between CMUTs within an element is investigated. Simulations show that the resonances at frequencies closest to the center frequency are reduced, while they are increased at lower frequencies. The lowermost resonances are also shifted down in frequency by 1.5-2.5% of the center frequency. An added lossy top layer with thicknesses from 10 mum to 30 mum reduces the unwanted effects to an acceptable level, but increases the center frequency of the array. The combination of added element kerf and a lossy layer result in responses with 80-100% bandwidth and less than 1.5 dB insertion loss at 0 degrees steering angle. Reoptimizing the design might increase the bandwidth.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"24 1","pages":"2155-2158"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89486674","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
3D-1 Absolute Transit Time Detection for Ultrasonic Gas Flowmeters Based on Time and Phase Domain Characteristics 基于时相域特性的超声气体流量计3D-1绝对传输时间检测
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.47
M. Kupnik, E. Krasser, M. Groschl
{"title":"3D-1 Absolute Transit Time Detection for Ultrasonic Gas Flowmeters Based on Time and Phase Domain Characteristics","authors":"M. Kupnik, E. Krasser, M. Groschl","doi":"10.1109/ULTSYM.2007.47","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.47","url":null,"abstract":"We present an absolute transit time detection algorithm for ultrasonic gas flowmeters (UFMs). The major objective is a reliable and accurate detection, even when the received signals experience a change and degradation of their shape. This can be due to parasitic effects, such as high gas temperatures and pressure fluctuations. We employ a time and phase domain based detection algorithm that determines the absolute transit times independently for the upstream and downstream channel. The Hilbert transform is applied to calculate the wrapped phase signal; each section of this phase signal is analyzed step-by- step. The algorithm was tested on real measurement data obtained from a double-path UFM (wetted configuration using capacitive ultrasonic transducers) installed at the end of an exhaust gas train of an automotive combustion engine. Over a gas temperature range of 400degC and a mass flow range of 163 kg/h, corresponding to a signal- to-noise ratio (SNR) range from 18 to 8 dB, all transit times were detected correctly, i.e. without any cycle skip. Further, our results show that the algorithm outperforms cross-correlation methods in terms of the absolute transit time detection.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"1 1","pages":"142-145"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89907359","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 22
6D-5 Modeling the Rf Acoustic Behavior of Love-Wave Sensors Loaded with Organic Layers 6D-5负载有机层Love-Wave传感器的射频声学特性建模
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.130
L. E. Fissi, J. Friedt, S. Ballandras
{"title":"6D-5 Modeling the Rf Acoustic Behavior of Love-Wave Sensors Loaded with Organic Layers","authors":"L. E. Fissi, J. Friedt, S. Ballandras","doi":"10.1109/ULTSYM.2007.130","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.130","url":null,"abstract":"In order to exploit complicated combinations of measurements associated with acoustic devices, we present the results of finite element/boundary element analyses including visco-elastic losses on fluid-loaded love-wave based devices, used as microbalance for biochemical detection and sensing purposes. The P-matrix characteristics of the mode are extracted from these computations to simulate the implemented devices. The corresponding frequency dependent phase shift and acoustic losses are introduced in the P-matrix model, allowing for an accurate prediction of insertion losses and phase sensitivity of our love-wave delay lines. Comparison between theory and experiments shows that we are capable to accurately predict the influence of viscosity on the insertion losses of the love-wave microbalance.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"97 1","pages":"484-487"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89985825","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
P6D-2 Ultrasound Bone Segmentation Using Dynamic Programming 基于动态规划的P6D-2超声骨分割
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.635
P. Foroughi, E. Boctor, M. Swartz, R. H. Taylor, G. Fichtinger
{"title":"P6D-2 Ultrasound Bone Segmentation Using Dynamic Programming","authors":"P. Foroughi, E. Boctor, M. Swartz, R. H. Taylor, G. Fichtinger","doi":"10.1109/ULTSYM.2007.635","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.635","url":null,"abstract":"Segmentation of bone surface in ultrasound images has numerous applications in computer aided orthopedic surgery. A robust bone surface extraction technique for ultrasound images can be used to non-invasively probe the bone surface. In this work, we present early results with an intuitive and computationally inexpensive bone segmentation approach. The prior knowledge about the appearance of bone in ultrasound images is exploited toward achieving robust and fast bone segmentation. Continuity and smoothness of the bone surface are incorporated in a cost function, which is globally minimized using dynamic programming. The performance of this method is evaluated on ultrasound images collected from two male cadavers. The images are segmented in about half a second making the algorithm suitable for real-time applications. Comparison between manual and automatic segmentation shows an average accuracy of less than 3 pixels (0.3 mm).","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"36 1","pages":"2523-2526"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90794386","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 76
P4L-3 Anisotropic Wave-Surface Shaped Annular Interdigital Transducer P4L-3各向异性波面环形数字间换能器
2007 IEEE Ultrasonics Symposium Proceedings Pub Date : 2007-12-26 DOI: 10.1109/ULTSYM.2007.532
V. Laude, D. Gérard, N. Khelfaoui, C. Jerez-Hanckes, S. Benchabane, H. Moubchir, A. Khelif
{"title":"P4L-3 Anisotropic Wave-Surface Shaped Annular Interdigital Transducer","authors":"V. Laude, D. Gérard, N. Khelfaoui, C. Jerez-Hanckes, S. Benchabane, H. Moubchir, A. Khelif","doi":"10.1109/ULTSYM.2007.532","DOIUrl":"https://doi.org/10.1109/ULTSYM.2007.532","url":null,"abstract":"Interdigital transducers (IDT) are widely used to generate surface acoustic waves directly on piezoelectric materials. However, in most applications, the generating fingers are straight, giving rise to the emission of plane waves. One notable exception is the circular IDT proposed by Day and Koerber for isotropic substrates [IEEE Trans. Sonics and Ultrason. SU-18, 461 (1972)]. More recently, the focused interdigital transducer (FIDT) has been used to obtain high intensity generation at the focal spot. The FIDT uses surface wave emission inside a circular arc for concentrating acoustic energy at its focus. However, the anisotropy of the substrate can lead to aberrations at the focal point. We investigate the problem of constructing an extended source that will focus elastic energy to a single point on the surface of a piezoelectric crystal. On the surface of a piezoelectric solid that is mechanically excited at a single point, concentric waves originate and form in the far field a ripple pattern that follows the shape of the wave surface, obtained by plotting the group velocity as a function of the emission angle. We conversely propose the concept of an annular interdigital transducer (AIDT), in which the shape of the fingers follows the wave surface. The surface acoustic waves generated by an AIDT are expected to converge to the center of the transducer, producing a spot that is limited in resolution by diffraction only. Experiments have been conducted on Y and Z cut lithium niobate (LiNbO3). AIDTs operating at a resonance frequency of 75 MHz have been constructed. Electrical measurements show that despite anisotropy in-phase emission at all angles is obtained for Rayleigh waves. In addition, spatial maps of the displacements at the surface have been obtained using a heterodyne optical probe, showing an important focusing of surface acoustic waves in the center of the device. The measured displacement fields at resonance show surface ripples converging to a spot at the center of the transducer. This result is promising for several applications including intense microacoustic sources.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"32 1","pages":"2115-2118"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89592384","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信