Journal of Medical Devices最新文献

筛选
英文 中文
Modeling and Admittance Control of a Piezoactuated Needle Insertion Device for Safe Puncture of Spinal Membranes 用于安全穿刺脊膜的压电针插入装置的建模和导纳控制
Journal of Medical Devices Pub Date : 2024-07-22 DOI: 10.1115/1.4066045
Yuzhou Duan, Jie Ling, Yuchuan Zhu
{"title":"Modeling and Admittance Control of a Piezoactuated Needle Insertion Device for Safe Puncture of Spinal Membranes","authors":"Yuzhou Duan, Jie Ling, Yuchuan Zhu","doi":"10.1115/1.4066045","DOIUrl":"https://doi.org/10.1115/1.4066045","url":null,"abstract":"\u0000 The most challenging procedure for lumbar puncture (LP) is accurately puncturing the spinal membrane (dura mater) based on an automatic needle insertion device (NID). Piezoactuated NID has shown its advantages in robotic-assisted LP with high precision and compact structure. Soft control of the NID is important for insertion safety; however, for stick-slip piezo-actuated NID, there are few studies due to the complex mechanism of stick-slip motion. Here, a modeling and admittance control method for a proposed stick-slip piezoactuated NID is proposed for safe puncture of the spinal membrane. To analytically model the NID, the compliant mechanism (CM) in the NID is reduced to a second-order system. The stick-slip friction and the spinal membrane are modeled based on the LuGre model and the Hunt-Crossley model, respectively. Based on these models, an admittance controller (AC) for the proposed NID is established to realize the precise control of the position and the safety protection against puncture errors. Simulations and preliminary experiments based on a prototype of the NID and a phantom of the spinal membrane were carried out to test the proposed modeling and control method. Results show that the proposed NID with AC has a maximum insertion error of 0.62 mm and the insertion depth decays by 80% when an unexpected force is applied. Therefore, the proposed model and control method have the potential to be used in real LP procedures by further development.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"37 18","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141816777","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance Evaluation of Neonatal Anti-Pressure Ulcer Bed Using a Novel Force Sensing Array 使用新型力传感阵列评估新生儿抗压溃疡床的性能
Journal of Medical Devices Pub Date : 2024-07-04 DOI: 10.1115/1.4065892
A. Mallick, Bijit Basumatary, Mukesh Kumar, Kamaldeep Arora, Durba Pal, A. Sahani
{"title":"Performance Evaluation of Neonatal Anti-Pressure Ulcer Bed Using a Novel Force Sensing Array","authors":"A. Mallick, Bijit Basumatary, Mukesh Kumar, Kamaldeep Arora, Durba Pal, A. Sahani","doi":"10.1115/1.4065892","DOIUrl":"https://doi.org/10.1115/1.4065892","url":null,"abstract":"\u0000 Objective: Pressure ulcer (PU) is a serious issue among newborns, particularly those who are premature and have medical conditions that require hospitalization. Existing conventional beds require the modifications that can reduce the chance of PU and extra effort of nursing staff. Methods: In this work, a force-sensing resistor array (FSRA) mattress is implemented that detects high-pressure points. The microcontroller processes the data that are collected from the FSRA using an electronic circuit based on the principle of voltage divider circuits. The multiplexer identifies the pixels of high-pressure points and plots the heat maps using MATLAB. Results: The results of the FSRA mattress use an alternately inflating and deflating pressure channel bed act as an anti-PU bed and compares it with the currently deployed bed. The demonstrated work was validated using the Finite Element Modeling framework. Conclusion: This anti-PU bed is effective in detecting high-pressure points; based on that, chances of PUs in neonates can be prevented. The performance evaluation of the designed and tested anti-PU bed with more accuracy and automatically varies the contact position to reduce the efforts made by the nursing staff. Clinical impact: This innovation significantly improves the quality of life as compared to the conventional methods to avoid PUs for NICUs.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":" 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141677547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Development of a Novel Peristaltic Test Stand “Swallow-Sim” for the Mechanical Evaluation of Esophageal Stents 开发新型蠕动试验台 "Swallow-Sim",用于食管支架的机械评估
Journal of Medical Devices Pub Date : 2024-07-01 DOI: 10.1115/1.4065906
Daniel Berger, Jan T. Sehrt, Thomas Brinkmann, Niclas Norman Henrichs, Oguzhan Bilec, Karl-Hermann Fuchs, Alexander Meining
{"title":"The Development of a Novel Peristaltic Test Stand “Swallow-Sim” for the Mechanical Evaluation of Esophageal Stents","authors":"Daniel Berger, Jan T. Sehrt, Thomas Brinkmann, Niclas Norman Henrichs, Oguzhan Bilec, Karl-Hermann Fuchs, Alexander Meining","doi":"10.1115/1.4065906","DOIUrl":"https://doi.org/10.1115/1.4065906","url":null,"abstract":"\u0000 Development of medical products begins with the “in silico” phase, where the development and simulation of new stent types is carried out. This is followed by the “in vitro” phase. Here, tests are done in a test stand to obtain initial conclusions about the interaction of the environment. The approval process is completed in the “in vivo” phase, where testing in living beings happen. Here, preclinical studies are carried out in animals first, followed by clinical studies on patients. A big part of the development fails in this final phase, as this is where the interactions of all influences from the stent environment are investigated. Since this not only causes high costs for the developers, but also unnecessarily destroys living resources in animal studies, this publication describes the development of a test stand called \"SwallowSim\" that superimposes the mechanical influences of the esophagus, the chemical stress caused by hydrochloric acid and increased body temperature. Furthermore, tests of the acting pressures are carried out using esophageal manometry, a temperature test of the test stand and a test run of the gastric juice. At the end of this publication, the results are evaluated with a six-week test of a Nickel Titanium Naval Ordnance Laboratory stent, which loses much of its mechanical properties and is partially destroyed by the load. The results show a clear correlation with the findings from reality. The test stand should be further optimised and examined in more detail in further tests and subjected to a reality check.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"72 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141691369","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of an Esophageal Sleeve with Variable Stiffness and Internal Diameter for Endoscopic Surgery 为内窥镜手术开发具有可变硬度和内径的食管套筒
Journal of Medical Devices Pub Date : 2024-07-01 DOI: 10.1115/1.4065836
Haibo Wang, Xinwei Liu, Zongyu Chang
{"title":"Development of an Esophageal Sleeve with Variable Stiffness and Internal Diameter for Endoscopic Surgery","authors":"Haibo Wang, Xinwei Liu, Zongyu Chang","doi":"10.1115/1.4065836","DOIUrl":"https://doi.org/10.1115/1.4065836","url":null,"abstract":"\u0000 In natural orifice transluminal endoscopic surgery, the flexible endoscopic surgical robot utilizes a continuum configuration to navigate narrow, multi-curvature esophageal pathways. However, the tool channel's dimensional limitations and the restricted internal layout make it challenging to reduce the outside diameter and highly efficient variable stiffness function significantly. As a result, safe insertion into the esophagus and precise operation remains hugely challenging. In this paper, an esophageal sleeve with variable stiffness and internal diameter is developed for endoscopic procedures. The proposed esophageal sleeve adopts specially designed spiral elastic deployable parts that allow for variations in internal diameter. Furthermore, the elastic deployable parts are designed with serrated protrusion structures that can realize rapid transition between rigidity and flexibility under negative pressure. Fundamental experimental results showed that the outer diameter of the proposed esophageal sleeve can expand from 17 mm to 20 mm, providing inner access up to 13 mm for endoscopic instruments. The serrated protrusion structure allows the esophageal sleeve to rapidly transition from a flexible to a rigid state, resulting in a stiffness gain of approximately 5. Phantom experiments validated the effectiveness and usability of the proposed Esophageal sleeve in assisting endoscope insertion, demonstrating its potential clinical value in endoscopic procedures.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"55 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141716165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Toward Smart Ultrasound Image Augmentation to Advance Tumor Treatment Monitoring: Exploring the Potential of Diffusion Generative Model 实现智能超声图像增强,推进肿瘤治疗监测:探索扩散生成模型的潜力
Journal of Medical Devices Pub Date : 2024-07-01 DOI: 10.1115/1.4065905
Emmanuel Yangue, Ashish Ranjan, Yu Feng, Chenang Liu
{"title":"Toward Smart Ultrasound Image Augmentation to Advance Tumor Treatment Monitoring: Exploring the Potential of Diffusion Generative Model","authors":"Emmanuel Yangue, Ashish Ranjan, Yu Feng, Chenang Liu","doi":"10.1115/1.4065905","DOIUrl":"https://doi.org/10.1115/1.4065905","url":null,"abstract":"\u0000 Medical imaging is a crucial tool in clinics to monitor tumor treatment progress. In practice, many imaging tools (such as MRI and CT scans) are in general costly and may also expose patients to radiation, leading to potential side effects. Recent studies have demonstrated that ultrasound imaging, which is safe, low-cost, and easy to access, can monitor the drug delivery progress in solid tumors. However, the noisy nature of ultrasound images and the high-level uncertainty of cancer disease progression are still challenging in ultrasound-based tumor treatment monitoring. To overcome these barriers, this work presents a comparative study to explore the potential advantages of the emerging diffusion generative models against the commonly applied state-of-the-art generative models. Namely, the denoising diffusion models (DDMs), against the generative adversarial networks (GAN), and variational autoencoders (VAE), are used for analyzing the ultrasound images through image augmentation. These models are evaluated based on their capacity to augment ultrasound images for exploring the potential variations of tumor treatment monitoring. The results across different cases indicate that the DDIM/KID-IS model leveraged in this work outperforms the other models in the study in terms of similarity, diversity, and predictive accuracy. Therefore, further investigation of such diffusion generative models could be considered as they can potentially serve as a great predictive tool for ultrasound image-enabled tumor treatment monitoring in the future.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"34 5","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141688877","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Robotic System with a Bendable Catheter for Laparoendoscopic Single Site Surgery 带可弯曲导管的机器人系统,用于腹腔镜单部位手术
Journal of Medical Devices Pub Date : 2024-06-14 DOI: 10.1115/1.4065730
Zhenxuan Hu, Jinhua Li, Xingchi Liu, Shuxin Wang
{"title":"A Robotic System with a Bendable Catheter for Laparoendoscopic Single Site Surgery","authors":"Zhenxuan Hu, Jinhua Li, Xingchi Liu, Shuxin Wang","doi":"10.1115/1.4065730","DOIUrl":"https://doi.org/10.1115/1.4065730","url":null,"abstract":"\u0000 Robotic Laparoendoscopic Single Site Surgery (LESS) is emerging as a hot research topic with the advancement of robotics. However, the movement of the rigid catheter inserted through a fixed incision into the patient's body cavity is constrained to a conical workspace, and the surgical instruments introduced through channels in the catheter can hardly perform necessary operations when the target tissue is close to the boundary of this workspace. In this paper, we present a novel robotic system for LESS with a bendable catheter that allows the catheter centerline to be oriented towards the target tissue over a larger area, thus providing a better initial position for the surgical instruments and enlarging the workspace of the instruments. The diameter of the bendable catheter is 30 mm and the length is 22 mm. The bendable portion of the catheter provides 2 degrees of freedom (DOF) within the body cavity and can be bent up to 45°. The system consists of two continuum instruments with 6 DOF and a 3D endoscope with 5 DOF. System design, kinematic analysis and teleoperation algorithm are introduced in detail. Preliminary experiments are performed to verify the feasibility and effectiveness of the proposed system. The results prove the applicability of the system in LESS.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"12 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141340752","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design and Evaluation of Kirschner Wire Guide Device for Patellar Fracture Fixation 用于髌骨骨折固定的 Kirschner 导丝装置的设计与评估
Journal of Medical Devices Pub Date : 2024-05-21 DOI: 10.1115/1.4065578
yan zhang, Haipo Cui, Kewei Du, Xudong Guo, Ruonan Fu, Qi Zhang
{"title":"Design and Evaluation of Kirschner Wire Guide Device for Patellar Fracture Fixation","authors":"yan zhang, Haipo Cui, Kewei Du, Xudong Guo, Ruonan Fu, Qi Zhang","doi":"10.1115/1.4065578","DOIUrl":"https://doi.org/10.1115/1.4065578","url":null,"abstract":"\u0000 Identifying the optimal position for Kirschner wire (K-wire) is crucial in tension band wiring for patellar fracture. This study analyzed the ideal position and designed a guide device to aid precise K-wire insertion. The stress and displacement at 90° of flexion were compared to determine the optimal positions. The number of insertions and fluoroscopies, and operating times were recorded in a retrospective study. Intraoperative radiographs were used to measure the K-wire position relative to the patella in the coronal and sagittal planes to assess accuracy. The least stability occurred when the distance between the K-wires was 1/2 of the patellar width in the coronal plane and close to the patellar anterior surface. The number of K-wire insertions in the experimental group and control group (1.33 ±0.58 vs 3.8 ±1.03; P = 0.009), the number of fluoroscopies (2.67 ±0.58 vs 10 ±1.33; P = 0.007), and the operating time (55 ±8.66 min vs 82 ±9.49 min; P = 0.001) were significantly different. K-wires should parallel to each other, spaced 1/4 or 1/3 of the patellar width in the coronal plane, and 1/2 to 3/4 of the patellar thickness in the sagittal plane away from the patellar anterior surface. The surgeon could improve insertion accuracy with guide device.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"4 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141114130","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Modular Nitinol Model with Lode Angle-Based Asymmetry and Improved Representation of the Superelastic Loops for Medical Device Applications 基于洛德角不对称的模块化镍钛诺模型,以及医疗器械应用中超弹性环的改进表示方法
Journal of Medical Devices Pub Date : 2024-05-16 DOI: 10.1115/1.4065513
John Mould, Alex Kelly, Ashley Peterson, Nuno Rebelo
{"title":"A Modular Nitinol Model with Lode Angle-Based Asymmetry and Improved Representation of the Superelastic Loops for Medical Device Applications","authors":"John Mould, Alex Kelly, Ashley Peterson, Nuno Rebelo","doi":"10.1115/1.4065513","DOIUrl":"https://doi.org/10.1115/1.4065513","url":null,"abstract":"\u0000 We describe a phenomenological constitutive model for representing Nitinol in medical device applications. The intent is to capture some of the response features important to medical device applications that are neglected in prevalent state of the art models. These features include better representation of the response under compression which is needed to assess bending, and asymmetric plastic yield. We will refer to this implementation as the Thornton Tomasetti (TT) model to distinguish it from other existing implementations that have evolved from the baseline underlying theory. We implement the model in a modular form suitable for use in commercial finite element software and describe initialization from laboratory test data.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"40 14","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140970468","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design, Fabrication, and Validation of a Portable Perturbation Treadmill for Balance Recovery Research 设计、制造和验证用于平衡恢复研究的便携式扰动跑步机
Journal of Medical Devices Pub Date : 2024-05-16 DOI: 10.1115/1.4065514
Robert Knutson, Justin Whitten, David Graham, Craig Shankwitz, Corey Pew
{"title":"Design, Fabrication, and Validation of a Portable Perturbation Treadmill for Balance Recovery Research","authors":"Robert Knutson, Justin Whitten, David Graham, Craig Shankwitz, Corey Pew","doi":"10.1115/1.4065514","DOIUrl":"https://doi.org/10.1115/1.4065514","url":null,"abstract":"\u0000 Trips and falls are a major concern for older adults. The resulting injury and loss of mobility can have a significant impact on quality of life. An emerging field of study, known as Perturbation Training, has been shown to reduce injury rates associated with trips and falls in older adults. Treadmills traditionally used for Perturbation Training are large, expensive, and immobile, forcing users to travel long distances to receive care. A portable treadmill would serve a larger portion of the at-risk population than current methods. We developed a portable, low-cost, twin-belt perturbation treadmill capable of high-intensity Perturbation Training. Belt speeds are controlled by a custom mechanical and software interface, allowing operators with no programming experience to control the device. The treadmill can accommodate users up to 118 kg and provides a maximum acceleration and speed of 12 m/s2 and 3.3 m/s, respectively, under full load. The total weight is 180 kg, and the treadmill can be moved like a wheelbarrow, with handles in the back and wheels in the front. The prototype was validated with mechanical and human participant testing, showing it as a viable device for Perturbation Training. In this paper, we will go over the design, fabrication, and validation processes used to create the Portable Perturbation Treadmill.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"56 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140971001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A miniaturized endoscopic device integrating Raman spectroscopy and laser speckle technology via an image fusion algorithm for intraoperative identification and functional protection of parathyroid glands 通过图像融合算法整合拉曼光谱和激光斑点技术的微型内窥镜设备,用于术中识别和功能性保护甲状旁腺
Journal of Medical Devices Pub Date : 2024-05-07 DOI: 10.1115/1.4065481
Qiye Wen, Chang Cai, Jiayi Fang, Zifeng Luo, Yuanwei Luo, Chong Wang, Weixiong Liang, Song Wang
{"title":"A miniaturized endoscopic device integrating Raman spectroscopy and laser speckle technology via an image fusion algorithm for intraoperative identification and functional protection of parathyroid glands","authors":"Qiye Wen, Chang Cai, Jiayi Fang, Zifeng Luo, Yuanwei Luo, Chong Wang, Weixiong Liang, Song Wang","doi":"10.1115/1.4065481","DOIUrl":"https://doi.org/10.1115/1.4065481","url":null,"abstract":"\u0000 Thyroid surgeons have increasingly emphasized functional protection in thyroid surgery, including the hot and difficult issue of intraoperative identification and functional protection of parathyroid glands. Intraoperative parathyroid imaging methods can identify parathyroid glands to some extent, but they have limitations in cases where contrast agents are used preoperatively or frozen sections are used postoperatively.This paper presents the design and validation of a miniaturized and integrated all-in-one parathyroid-specific lumenscope. The device integrates Raman spectroscopy and laser scattering technology and utilizes algorithms to locate the parathyroid glands. Its purpose is to provide real-time protection of the parathyroid glands without the need for dye-based tissue identification. The device comprises two distinct parts: the mechanics of the cavity lens used for surgical operations and the design of the software system that fuses the image signals. It has been validated in ex vivo tissue experiments and preliminary clinical trials to enable miniaturization and integration of visual fluorescence localization techniques. The device aims to achieve objective, safe, accurate, and convenient parathyroid function protection.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"22 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141005126","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信