Brazilian Journal of Radiation Sciences最新文献

筛选
英文 中文
An easy and direct protocol based on planar molecular images to quantify 131I using thyroid phantom 基于平面分子图像的简便直接方案,利用甲状腺模型量化 131I
Brazilian Journal of Radiation Sciences Pub Date : 2023-12-29 DOI: 10.15392/2319-0612.2023.2325
Danny Giancarlo Apaza-Veliz, Vinicus Fernando dos Santos, D. L. Franze, Wilson Furlan Matos Alves, Eder Rezende Moraes
{"title":"An easy and direct protocol based on planar molecular images to quantify 131I using thyroid phantom","authors":"Danny Giancarlo Apaza-Veliz, Vinicus Fernando dos Santos, D. L. Franze, Wilson Furlan Matos Alves, Eder Rezende Moraes","doi":"10.15392/2319-0612.2023.2325","DOIUrl":"https://doi.org/10.15392/2319-0612.2023.2325","url":null,"abstract":"A planar nuclear medicine image can be used to estimate dosimetry during iodine therapy. To this end, radionuclide activity distribution should be quantified in the patient’s body in terms of a calibration coefficient. This coefficient allows the net counts to correlate with the image’s activity. This study aims propose a simple and easy calibration protocol to quantify 131I activity in thyroid phantom by molecular planar images. Were acquired 13 planar images of different phantoms: thyroid phantom of symmetrical lobes; thyroid phantom of asymmetrical lobes; the Jacszack cylinder phantom with a syringe surrounded by air and water, and finally a plastic bottle containing a syringe with radionuclide. We applied the 131I radionuclide in a General Electric gamma camera, model Discovery NM/CT 670 with a high energy general purpose parallel hole collimator above the phantoms positioned at camera bed. The calibration coefficient of the gamma camera and the standard deviation were determined for each phantom; the average calibration coefficient obtained was 0.062±0.006 MBq/cps. The results suggested that the phantoms applied as too the calibration coefficient obtained by them can provides reasonable value for the gamma camera calibration factor for iodine 131, therefore an accurate evaluation of the scattering media as the source detector distance could impose higher variability and uncertainties on results.","PeriodicalId":505520,"journal":{"name":"Brazilian Journal of Radiation Sciences","volume":" 2","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139142465","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信