International Journal of Prosthodontics最新文献

筛选
英文 中文
EFFECT OF IMMERSION IN WATER ON DEFORMATION WITH A VARIETY OF DENTURE BASE MATERIALS AND MANUFACTURING TECHNIQUES. 在水中浸泡对各种义齿基托材料和制造技术变形的影响。
IF 2.1 4区 医学
International Journal of Prosthodontics Pub Date : 2024-06-21 DOI: 10.11607/ijp.8332
Po-Ju Huang, Tong-Mei Wang, Li-Deh Lin, Tsung- Chieh Yang
{"title":"EFFECT OF IMMERSION IN WATER ON DEFORMATION WITH A VARIETY OF DENTURE BASE MATERIALS AND MANUFACTURING TECHNIQUES.","authors":"Po-Ju Huang, Tong-Mei Wang, Li-Deh Lin, Tsung- Chieh Yang","doi":"10.11607/ijp.8332","DOIUrl":"10.11607/ijp.8332","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of immersion in water on deformation of maxillary denture bases created with CAD/CAM and heat-polymerized resin fabrication techniques under loading condi8ons.</p><p><strong>Materials and methods: </strong>2-mm-thick denture bases were fabricated using four techniques: CAD/CAM milling (CCM; Polywax PMMA blank, Yamachi PMMA disk Yamahachi Dental); 3D prin8ng (3DP; BV005, NextDent Base); compression molding (CM; Luciton 199, Dentsply Sirona); and injec8on molding (IM; Ivobase, Ivoclar; n = 5 per group). Three static 49-N loads were applied perpendicular to each denture base, and the mean strain value (MSV) was recorded with strain gauges a[ached to the denture surface. The denture bases were stored at 37°C in distilled water for 14 and 28 days, and the MSVs under the same static load were recorded.</p><p><strong>Results: </strong>The highest MSVs were observed at the posterior palatal seal, tuberosity, and labial notches of the dentures. The lowest MSVs were recorded for the CCM group and then the CM and IM groups. The highest MSVs were recorded for the 3DP group. No significant differences in regional MSVs (P > .05) were observed among the CCM, CM, and IM aber 14 and 28 days in water. Large devia8ons in MSVs were recorded for the 3DP group across the measurement sites aber water exposure (P < .05).</p><p><strong>Conclusions: </strong>CCM had the lowest denture deformation under static loading. After immersion in water, the deformation changes under static loading were stable for CCM, CM, and IM. However, variations among the materials used in 3DP group influenced the mechanical performance and presented larger deformations.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"123-135"},"PeriodicalIF":2.1,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9919093","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Heat Transfer Through Various Fixed Prosthetic Materials During Grinding. 不同固定修复材料在磨削过程中的传热比较
IF 2.1 4区 医学
International Journal of Prosthodontics Pub Date : 2024-06-21 DOI: 10.11607/ijp.8292
Burcu Bal, Selen Erkul, Zeynep Ozkurt-Kayahan, Ender Kazazoglu
{"title":"Comparison of Heat Transfer Through Various Fixed Prosthetic Materials During Grinding.","authors":"Burcu Bal, Selen Erkul, Zeynep Ozkurt-Kayahan, Ender Kazazoglu","doi":"10.11607/ijp.8292","DOIUrl":"10.11607/ijp.8292","url":null,"abstract":"<p><strong>Purpose: </strong>To measure and compare the mean temperature values due to heat generated during the grinding of different prosthetic materials with diamond burs using a high-speed instrument with and without water cooling.</p><p><strong>Materials and methods: </strong>In total, 120 disk-shaped specimens (10 × 2 mm), each with a smaller disk in the center (3 × 2 mm), were fabricated from yttrium-stabilized zirconia, monolithic zirconia, glass-ceramic, indirect composite, polyetheretherketone (PEEK), and cast metal (Ni-Cr alloy). The specimens were divided into six groups (n = 20) according to material type. The specimens in each group were ground continuously with a high-speed handpiece and diamond burs with (n = 10) and without (n = 10) water cooling until the smaller disks were removed. Two different methods (thermocouple and thermal camera) were used to measure the temperature during the grinding process. Results were analyzed using two-way ANOVA and paired-samples t test (P < .05).</p><p><strong>Results: </strong>PEEK had the lowest mean temperature and metal had the highest values, both with and without water cooling, according to data measured with a thermocouple. Zirconia and monolithic zirconia samples without water cooling had the highest mean temperature when measured with a thermal camera. Both with and without water cooling, composite samples had the lowest mean temperatures for thermal camera measurements.</p><p><strong>Conclusions: </strong>Water cooling is strongly recommended when grinding all prosthetic materials. The heat transferred to the supporting teeth may depend on the thermal conductivity of the material used.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"300-305"},"PeriodicalIF":2.1,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9488006","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Clinical Outcomes of Tooth- and Implant- Supported Restorations Performed in a University-Based Undergraduate Program After 13 to 15 Years. 13-15 年后在大学本科课程中进行的牙科和种植体支持修复的临床效果。
IF 2.1 4区 医学
International Journal of Prosthodontics Pub Date : 2024-06-21 DOI: 10.11607/ijp.8264
Sarah Ermatinger, Wan-Zhen Lee, Daniel S Thoma, Jürg Hüsler, Christoph H F Hämmerle, Nadja Naenni
{"title":"Clinical Outcomes of Tooth- and Implant- Supported Restorations Performed in a University-Based Undergraduate Program After 13 to 15 Years.","authors":"Sarah Ermatinger, Wan-Zhen Lee, Daniel S Thoma, Jürg Hüsler, Christoph H F Hämmerle, Nadja Naenni","doi":"10.11607/ijp.8264","DOIUrl":"10.11607/ijp.8264","url":null,"abstract":"<p><strong>Purpose: </strong>To assess the clinical concept of patient treatment with fixed tooth- and implant-supported restorations in a university-based undergraduate program after 13 to 15 years.</p><p><strong>Materials and methods: </strong>In total, 30 patients (mean age 56 years) who had received multiple tooth- and implant-supported restorations were recalled after 13 to 15 years. The clinical assessment comprised biologic and technical parameters as well as patient satisfaction. Data were analyzed descriptively, and the 13- to 15-year survival rates for tooth- and implant-supported single crowns and fixed dental prostheses (FDPs) were calculated.</p><p><strong>Results: </strong>The survival rate of tooth-supported restorations amounted to 88.3% (single crowns) and 69.6% (FDPs); in implants, it reached 100% for all types of restorations. Overall, 92.4% of all restorations were free of technical complications. The most common technical complication was chipping of the veneering ceramic (tooth-supported restorations: 5.5%; implant-supported restorations: 13% to 15.9%) regardless of the material used. For tooth-supported restorations, increased probing depth ≥ 5 mm was the most frequent biologic complication (22.8%), followed by endodontic complications of root canal-treated teeth (14%) and loss of vitality at abutment teeth (8.2%). Peri-implantitis was diagnosed in 10.2% of implants.</p><p><strong>Conclusions: </strong>The results of this study indicate that the clinical concept implemented in the undergraduate program and performed by undergraduate students works well. The clinical outcomes are similar to those reported in the literature. In general, the majority of biologic complications occur in reconstructed teeth, whereas implant-supported restorations are more prone to technical complications.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"261-270"},"PeriodicalIF":2.1,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9865804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Differences in Volumetric Tooth Loss for Monolithic Ceramic Crowns, Occlusal Overlays, and Partial-Coverage Onlays. 整体陶瓷冠、咬合覆盖层和部分覆盖嵌体的体积牙损失差异。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2024-04-22 DOI: 10.11607/ijp.8011
Clinton D Stevens, Emilio Couso-Queiruga, Danubio Blen, Walter G Renné
{"title":"Differences in Volumetric Tooth Loss for Monolithic Ceramic Crowns, Occlusal Overlays, and Partial-Coverage Onlays.","authors":"Clinton D Stevens, Emilio Couso-Queiruga, Danubio Blen, Walter G Renné","doi":"10.11607/ijp.8011","DOIUrl":"10.11607/ijp.8011","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the volumetric loss of clinical crown structure in commonly encountered clinical situations for monolithic ceramic crowns, occlusal overlays, and partial-coverage onlays.</p><p><strong>Materials and methods: </strong>Typodont teeth made with preexisting mesio-occlusodistal (MOD) preparations for mandibular first molars and maxillary first premolars were prepared with three different preparations: a full-contour monolithic zirconia crown, a lithium disilicate occlusal overlay, and mesio-occlusodistobuccal/mesio-occlusodistolingual (MODB/MODL) lithium disilicate onlays for premolars and molars. 3D-metrologic software was used to evaluate the volumetric loss of clinical crown structure for each preparation type. Subsequently, the mesiolingual cusps of mandibular molars and buccal cusps of maxillary premolars were excluded for a separate analysis to simulate patient presentation with an existing restoration and sheared-off cusp.</p><p><strong>Results: </strong>Full-coverage monolithic zirconia crowns removed 45.37 to 219.53 mm3 of the remaining clinical tooth structure, depending on the clinical scenario and tooth position, while lithium disilicate overlays removed 27.48 to 105.13 mm3 and MODB/MODL lithium disilicate onlays removed 5.48 to 47.45 mm3. In each scenario tested, MODB/MODL onlays removed significantly less clinical crown structure than overlays (P < .001); both MODB/MODL onlays and overlays removed significantly less structure than full-coverage crowns (P < .001).</p><p><strong>Conclusions: </strong>Monolithic zirconia crown restorations require significantly more removal of remaining tooth structure than lithium disilicate occlusal overlays and partial-coverage onlays for commonly occurring clinical situations requiring indirect restorations.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"181-189"},"PeriodicalIF":2.3,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9895395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Simulated Gastric Acid on the Interface Between Zirconia and Resin Cement. 模拟胃酸对氧化锆与树脂水泥界面的影响
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2024-04-22 DOI: 10.11607/ijp.8162
Natália Almeida Bastos-Bitencourt, Sandro Basso Bitencourt, Najm Alfrisany, Beshr Hajhamid, Grace Mendonca De Souza
{"title":"Effect of Simulated Gastric Acid on the Interface Between Zirconia and Resin Cement.","authors":"Natália Almeida Bastos-Bitencourt, Sandro Basso Bitencourt, Najm Alfrisany, Beshr Hajhamid, Grace Mendonca De Souza","doi":"10.11607/ijp.8162","DOIUrl":"10.11607/ijp.8162","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of simulated gastric acid solution (SGAS) and resin cement composition on the shear bond strength (SBS) of zirconia-based materials with different levels of translucency to composite resin.</p><p><strong>Materials and methods: </strong>A total of 40 medium-opacity (MO; 3Y-TZP) and 40 medium-translucency (MT; 4Y-PSZ) zirconia slabs were distributed into four groups according to the composition of the resin luting system (MDP free or with MDP [primer + Panavia V5]) and storage method (distilled water or SGAS [5% hydrochloric acid]). Composite resin cylinders were cemented on the zirconia surface and stored for 91 hours. SBS, failure mode, and surface characterization analyses via scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) were performed. SBS data were analyzed using three-way ANOVA and Tukey tests, and failure mode was assessed using one-way ANOVA (P < .05).</p><p><strong>Results: </strong>Storage media (P = .180), resin cement (P = .110), zirconia (P = .404), and their interactions did not affect SBS values. Bond strength ranged from 21.41 to 26.11 MPa. SEM images showed that SGAS modified the surface topography of zirconia and resin cement. The presence of chlorine and silicon (wt%) were higher after SGAS storage than after water storage in both cements used, while barium was higher only for the MDP cement. There was a prevalence of mixed failures for most of the groups.</p><p><strong>Conclusions: </strong>The SBS between both types of zirconia and resin cement was not affected by SGAS, although changes in zirconia topography were observed after SGAS exposure. The presence of MDP in the cement layer had no effect on the SBS challenged by SGAS.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"190-198"},"PeriodicalIF":2.3,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10361358","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Tea Tree Oil Addition to Denture Liners Against Candida albicans and Bond Strength to Acrylic Denture Bases. 茶树油添加到义齿衬垫中对白色念珠菌和丙烯酸义齿基托结合强度的影响。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2024-02-21 DOI: 10.11607/ijp.8368
Ayşe Günes, Elif Aydogan Ayaz, Cihan Inan
{"title":"Effect of Tea Tree Oil Addition to Denture Liners Against Candida albicans and Bond Strength to Acrylic Denture Bases.","authors":"Ayşe Günes, Elif Aydogan Ayaz, Cihan Inan","doi":"10.11607/ijp.8368","DOIUrl":"10.11607/ijp.8368","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of adding tea tree oil to denture liners on Candida albicans and bond strength to the acrylic denture base.</p><p><strong>Materials and methods: </strong>Disc-shaped specimens were fabricated from silicone-based resilient liner (Tokuyama, Molloplast), acrylic-based hard liner (GC Reline), and acrylic-based soft liner (Visco-gel). Tea tree oil (TTO) was incorporated into the liners at varying concentrations (0% [control], 2%, 5%, 8%). C albicans were counted by viable colony count, and optical density (OD) was measured with a spectrophotometer. The tensile strength to heat polymerized acrylic denture base was measured in a universal testing machine. The compliance of the data to the distribution of normality was evaluated using the Shapiro Wilk test. Two-way ANOVA, Bonferroni correction, and paired sample t test were performed (α = .05).</p><p><strong>Results: </strong>The addition of TTO into liners provided a significant decrease in the OD values (P < .001). The control groups of the liners presented the highest colony counts, whereas increasing TTO decreased the results (P < .01). According to tensile bond strength test, 8% TTO addition resulted in a significant decrease for Tokuyama (P < .01) and Molloplast liners (P < .05), while 2% TTO resulted in significance for GC Reline (P < .001).</p><p><strong>Conclusions: </strong>Denture liners containing increasing percentages of TTO presented lower amounts of C albicans colonies and decreased bond strength to the denture bases. When using TTO for its antifungal properties, the amount added should be carefully selected because the tensile bond strength may be affected.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"41-48"},"PeriodicalIF":2.3,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9510115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fit and Strength of a Three-Unit Temporary Prosthesis Made by Different Manufacturing Techniques: An In Vitro Study. 采用不同制造技术制造的三单元临时假体的密合性和强度:体外研究
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2024-02-21 DOI: 10.11607/ijp.8365
Rani D'haese, Renaat Coopman, Tom Vrombaut, Hugo de Bruyn, Stefan Vadenweghe
{"title":"Fit and Strength of a Three-Unit Temporary Prosthesis Made by Different Manufacturing Techniques: An In Vitro Study.","authors":"Rani D'haese, Renaat Coopman, Tom Vrombaut, Hugo de Bruyn, Stefan Vadenweghe","doi":"10.11607/ijp.8365","DOIUrl":"10.11607/ijp.8365","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the fit and fracture load of temporary fixed partial prostheses fabricated by means of a conventional direct technique, milling, or 3D printing.</p><p><strong>Materials and methods: </strong>A maxillary right first premolar and molar were prepared on a Frasaco cast, which was then duplicated 40 times. In total, 10 provisional three-unit fixed prostheses (Protemp 4, 3M) were made using the conventional technique with a putty mold. The 30 remaining casts were scanned to design a provisional restoration using CAD software. A total of 10 designs were milled (CEREC MC X5/shaded PMMA Disk, Dentsply Sirona), while the other 20 were 3D printed with one of the two 3D printers (Asiga UV MAX or Nextdent 5100, C&B, Nextdent). Internal and marginal fit were examined using the replica technique. Next, the restorations were cemented on their respective casts and loaded until fracture using a universal testing machine. The location and propagation of the fracture were also evaluated.</p><p><strong>Results: </strong>3D printing demonstrated the best internal fit. Nextdent (median internal fit: 132 μm) was significantly better compared to the milled (median internal fit: 185 μm; P = .006) and conventional restorations (median internal fit: 215 μm; P < .001), while the fit of Asiga (median internal fit: 152 μm) was only significantly better than the conventional restorations (P < .012). The lowest marginal discrepancy was found for the milled restorations (median marginal fit: 96 μm), but this was only significant when compared to the conventional group (median internal fit: 163 μm; P < .001). The conventional restorations demonstrated the lowest fracture load (median fracture load: 536 N), which was only significant when compared to Asiga (median fracture load: 892 N; P = .003).</p><p><strong>Conclusions: </strong>Within the present in vitro study's limitations, CAD/CAM demonstrated superior fit and strength compared to the conventional technique.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"34-40"},"PeriodicalIF":2.3,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9510118","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Digital Gothic Arch Tracing Device with Open- Source Software for CAD/CAM Denture Fabrication. 用于 CAD/CAM 义齿制作的数字哥特式牙弓跟踪设备与开源软件。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2024-02-21 DOI: 10.11607/ijp.8251
Ahmet Orgev, Wei-Shao Lin, Dean Morton
{"title":"Digital Gothic Arch Tracing Device with Open- Source Software for CAD/CAM Denture Fabrication.","authors":"Ahmet Orgev, Wei-Shao Lin, Dean Morton","doi":"10.11607/ijp.8251","DOIUrl":"10.11607/ijp.8251","url":null,"abstract":"<p><p>Digital or CAD/CAM workflows and protocols are being increasingly utilized because of their improved efficiency and reproducibility. For the fabrication of complete dentures, digital workflows can reduce treatment time and clinical visits while enhancing the reliability and reproducibility of the laboratory phase and materials. However, establishing centric relation (CR) and vertical dimension of occlusion (VDO) in a reproducible way is still a challenging step for complete denture fabrication in both analog and digital workflows. This clinical report describes a digital workflow using an individualized gothic arch tracing device (GATD) with open-source software for the fabrication of complete dentures. With this workflow, clinicians can offer customized solutions according to patient rehabilitation, with good reproducibility using gothic arch tracing to be implemented in the digital workflow.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"103-108"},"PeriodicalIF":2.3,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10369676","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Accuracy and Efficiency of Digitally Fabricated All-Ceramic Crowns from Conventional Impressions and Intraoral Scans: A Single-Blind Clinical Randomized Controlled Trial. 根据传统印模和口内扫描数字化制作全瓷牙冠的准确性和效率:单盲临床随机对照试验。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2024-02-21 DOI: 10.11607/ijp.8143
Xinggang Liu, Kun Feng, Ling Dong, Lixia Liu, Lin Ni, Dongxiang Zheng
{"title":"Accuracy and Efficiency of Digitally Fabricated All-Ceramic Crowns from Conventional Impressions and Intraoral Scans: A Single-Blind Clinical Randomized Controlled Trial.","authors":"Xinggang Liu, Kun Feng, Ling Dong, Lixia Liu, Lin Ni, Dongxiang Zheng","doi":"10.11607/ijp.8143","DOIUrl":"10.11607/ijp.8143","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the accuracy of intraoral scanners by comparing the marginal fit of 70 all-ceramic crowns fabricated from both conventional impressions and intraoral scans.</p><p><strong>Materials and methods: </strong>A total of 70 posterior teeth requiring single-crown restorations randomly underwent either intraoral scanning or conventional impression-taking, followed by laboratory scanning of the casts in a parallel-group randomized controlled trial (RCT). Subsequently, 70 monolithic all-ceramic crowns were CAD/CAM fabricated; only the impression technique differed. The marginal fit, internal fit, adjustment time required for insertion and occlusal contacts, and visual analog scale (VAS) scores assessing dentists' satisfaction with the crowns were clinically evaluated by a calibrated examiner who was blinded to the groups. Data were analyzed using independent samples t test and likelihood-ratio test or Fisher exact test. All tests were performed with α = .05.</p><p><strong>Results: </strong>The mean marginal fit with intraoral scanning (57.94 Å} 22.51 μm) was better than with diagnostic cast scanning (82.98 Å} 21.72 μm). The difference was statistically significant (P = .000). The differences in internal fit, adjustment time for crown insertion and occlusal contacts, and VAS scores were also significant, and the secondary outcomes were in favor of intraoral scanning.</p><p><strong>Conclusions: </strong>Within the limitations of this clinical trial, CAD/CAM-fabricated single-tooth restorations in the posterior region produced with an intraoral scanning technique using TRIOS were found to be a more accurate, efficient alternative to restorations based on conventional impressions in combination with the laboratory scanning technique.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"8-15"},"PeriodicalIF":2.3,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10369677","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Does Curing Delay Affect the Bond Strength of Fiber Post with Self-Adhesive Cements? 固化延迟会影响纤维桩与自粘水泥的粘结强度吗?
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-11-01 DOI: 10.11607/ijp.7486
Allegra Comba, Andrea Baldi, Elvinas Juzikis, Edoardo Alberto Vergano, Damiano Pasqualini, Mario Alovisi, Elio Berutti, Nicola Scotti
{"title":"Does Curing Delay Affect the Bond Strength of Fiber Post with Self-Adhesive Cements?","authors":"Allegra Comba,&nbsp;Andrea Baldi,&nbsp;Elvinas Juzikis,&nbsp;Edoardo Alberto Vergano,&nbsp;Damiano Pasqualini,&nbsp;Mario Alovisi,&nbsp;Elio Berutti,&nbsp;Nicola Scotti","doi":"10.11607/ijp.7486","DOIUrl":"10.11607/ijp.7486","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of three different curing protocols based on different ratios of self-curing and light-curing periods on the bond strength and nanoleakage of fiber posts luted with dual-curing self-adhesive cements.</p><p><strong>Materials and methods: </strong>A total of 48 single-root teeth were endodontically treated and obturated, and an 8-mm post space was prepared with dedicated drills. Specimens were randomly divided into two groups according to the self-adhesive cement employed: group 1 (G1) = PANAVIA SA Plus (Kuraray Noritake), and group 2 (G2) = Bifix SE (VOCO). The specimens were further divided into three subgroups (n = 8 each) according to the light-curing protocol applied: no light-curing (SG1), 20 seconds of light-curing 20 seconds after cement injection (SG2), and 20 seconds of light-curing 120 seconds after cement injection (SG3). Slices of 1-mm thickness were prepared for the pushout test and nanoleakage analyses of the coronal and apical regions after 24 hours of storage in artificial saliva. Results were statistically analyzed with three-way ANOVA and Tukey post hoc tests. Statistical significance was set for P < .05.</p><p><strong>Results: </strong>Three-way ANOVA analysis showed that the factors of cement (P = .02) and curing protocol (P < .001) had a significant influence on bond strength. Tukey post hoc test reported that light-curing 120 seconds after injection showed higher bond strength compared to both no light-curing and photoactivation after 20 seconds.</p><p><strong>Conclusion: </strong>To achieve the highest bond strength with self-adhesive cements, photoactivation with a 120-second delay after mixing is required. There is no difference between light-curing immediately and light-curing 20 seconds after mixing.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"595-602"},"PeriodicalIF":2.3,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10365582","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信