Progress in Medical Devices最新文献

筛选
英文 中文
Application and progress of functionalized magnetic bead-based biosensors for protein detection 功能化磁珠生物传感器在蛋白质检测中的应用与进展
Progress in Medical Devices Pub Date : 2024-12-26 DOI: 10.61189/403384jfzmyx
Haoyuan Su, Yuehua Liao, Shu Wu, Jun Ji, Shuya An, Dongdong Zeng
{"title":"Application and progress of functionalized magnetic bead-based biosensors for protein detection","authors":"Haoyuan Su, Yuehua Liao, Shu Wu, Jun Ji, Shuya An, Dongdong Zeng","doi":"10.61189/403384jfzmyx","DOIUrl":"https://doi.org/10.61189/403384jfzmyx","url":null,"abstract":"In the field of bioanalysis, the integration of magnetic beads and biosensors provides a protein detection platform with high separation efficiency and sensitivity. The superparamagnetism of magnetic beads, combined with surface functional modifications, forms the basis for selectively capturing and effectively separating target proteins. Additionally, the high sensitivity and specificity of biosensors ensure precise quantitative analysis of captured proteins. This article systematically reviews the synthesis strategies of functionalized magnetic beads, detection methods for proteins and nucleic acids, as well as the current technical challenges and future development directions.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://oss.zentimepublishing.com/upload/asset/20241231/be7d2300cac2eabe17eb448883e2ca596d3758ed.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147884612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
On Launching a New Journal 'Progress in Medical Devices' for Innovation 关于创刊《医疗器械进展》以促进创新
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/530844gerhbl
{"title":"On Launching a New Journal 'Progress in Medical Devices' for Innovation","authors":"","doi":"10.61189/530844gerhbl","DOIUrl":"https://doi.org/10.61189/530844gerhbl","url":null,"abstract":"Recent years have witnessed unprecedented advances in medical device industry. New technologies, such as 3D printing, organ-on-a-chip, and surgical robots, have emerged and iterated constantly. Innovation is the cornerstone in the development of medicine. Though we still need robust clinical data to evaluate the safety and effectiveness of these new technologies, we never stop our pursuit of more effective technologies and devices with a cautious attitude. With these intentions, we are pleased to introduce this new quarterly journal, Progress in Medical Devices.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136364467","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electromagnetic induction detection techniques for craniocerebral injury: A review 颅脑损伤电磁感应检测技术综述
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/729316upqdwc
{"title":"Electromagnetic induction detection techniques for craniocerebral injury: A review","authors":"","doi":"10.61189/729316upqdwc","DOIUrl":"https://doi.org/10.61189/729316upqdwc","url":null,"abstract":"Assessing the severity and prognosis of patients with craniocerebral damage is a major research area in medicine since it is a prevalent clinical disease. Acute craniocerebral injury, a common traumatic condition, is often caused by traffic accidents, collisions, and falls in daily life. Secondary craniocerebral injury refers to symptoms such as brain edema and intracranial hemorrhage after acute craniocerebral injury, which will aggravate the injury. Secondary craniocerebral injury can be avoided by effective and timely treatment, and real-time detection of brain edema and intracranial hemorrhage by non-invasive medical imaging is a solution. Therefore, non-invasive medical imaging technology has recently emerged as a new area of study. A new imaging technology, namely the brain injury detection technology based on electromagnetic induction, has been discovered after years of research on non-invasive detection of brain injury. Initially, electromagnetic induction technology was widely used in metal nondestructive testing. The human body, as a conductor, also has electromagnetic induction, allowing this technology to be used on the human body. This study reviews the technologies for detecting electromagnetic induction in cases of craniocerebral damage, including induced current electrical impedance tomography, magneto-acoustic tomography, and eddy current damping sensors for detection and imaging.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136364472","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Preparation and application of electro-conductive hydrogels in biomedical engineering 导电水凝胶的制备及其在生物医学工程中的应用
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/848897sppwnn
{"title":"Preparation and application of electro-conductive hydrogels in biomedical engineering","authors":"","doi":"10.61189/848897sppwnn","DOIUrl":"https://doi.org/10.61189/848897sppwnn","url":null,"abstract":"Electro-conductive hydrogel is a new composite hydrogel with high electrical conductivity, extraordinary mechanical properties, and controllability. It can be equipped with specific materials to obtain specific properties, which has attracted considerable research attention due to its wide range of application as a biomaterial in the biomedical engineering field. It can be used as a patch to promote healing and as a dressing for burns and pressure wounds. In pharmaceutical science, it is widely studied as a carrier of targeted and quantitative drug release. In surgery, it can serve as a cell scaffold for implantable therapy. Currently, increasing research is focusing on the development of sensors as simulated skin for robots, as well as in health monitors for human activity and well-being. In this review, we summarize the classification and selection of conductive mediums, natural polymer hydrogel matrices, and the application of electro-conductive hydrogels in the fields of bioengineering and biomedicine. We delve into the properties of different conductive mediums and the principle of combining different hydrogel matrices and discuss the advantages and disadvantages of emerging composite hydrogels. Our focus extends to the forefront of conductive hydrogel research in various fields, while also elucidating the current problems and challenges in terms of performance integration, preparation process and practical applications.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136366038","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimizing electrode design to minimize thermal spread in radiofrequency-induced colonic anastomosis 优化电极设计以减少射频诱导结肠吻合术中的热扩散
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/716520irvmwh
{"title":"Optimizing electrode design to minimize thermal spread in radiofrequency-induced colonic anastomosis","authors":"","doi":"10.61189/716520irvmwh","DOIUrl":"https://doi.org/10.61189/716520irvmwh","url":null,"abstract":"Objective: To study temperature distribution in different electrodes and to evaluate thermal spread during colonic anastomosis induced by radiofrequency energy through finite element modeling, aiming to provide the basis for optimizing the design of new electrodes with improved effectiveness of electrosurgical welding. Methods: Three electrodes with the feature of concave-convex (CC), rail coupled concave-convex (rail-CC), and cross rail coupled concave-convex (cross rail-CC) were designed for radiofrequency-induced serosa-to-serosa colonic anastomoses to evaluate the thermal spread process by finite element modeling using COMSOL Multiphysics. Parameters used in the modeling were set with a peak voltage of 45 V, a duty cycle of 10% and a repetition rate of 1 s. Additionally, a three-dimensional finite element model of the cross rail-CC electrode was further constructed to compare temperature variation and distribution when the voltage Fwas applied to ridges of upper electrode alternately. Results: The electrode with CC design produced similar temperature between 'gap' and 'compressed' areas, whereas the electrode with rail-CC design exhibited the highest temperature at 'gap' and 'compressed' areas compared with those with CC and cross rail-CC designs. Moreover, the cross rail-CC electrode, by tightly occluding the upper and lower electrodes, could create uniform compression and temperature variation. When electric voltage was applied to ridges of upper electrode of the cross rail-CC electrode alternately, the temperature at 'gap' was half of that at the 'compressed' section, which was comparable to the temperature at 'compressed' area in the rail-CC electrode (p=0.241). Conclusion: Alternating application of voltage to ridges of upper electrode of the cross rail-CC electrode can potentially produce an optimal fusion zone by reducing thermal damage with low 'gap' temperature while keeping the 'compressed' temperature high.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136364289","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Control technologies of lower limb rehabilitation exoskeleton robots based on surface electromyography: A review 基于表面肌电图的下肢康复外骨骼机器人控制技术综述
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/478535cfhrmf
{"title":"Control technologies of lower limb rehabilitation exoskeleton robots based on surface electromyography: A review","authors":"","doi":"10.61189/478535cfhrmf","DOIUrl":"https://doi.org/10.61189/478535cfhrmf","url":null,"abstract":"The aging population is accompanied by a decline in human body function, leading to an increasing number of people with lower limb dysfunction, which has become a global public health challenge today. The lower limb rehabilitation exoskeleton robot based on surface electromyography is a current research hotspot. It can help people with lower extremity dysfunction perform better rehabilitation training. This review presents the analysis and processing of surface electromyography, feature extraction and recognition, as well as the control methods for lower limb rehabilitation exoskeleton robots.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136364473","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Precision cooling radiofrequency ablation under tumor boundary temperature control 肿瘤边界温度控制下的精密冷却射频消融
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/780603itrglq
{"title":"Precision cooling radiofrequency ablation under tumor boundary temperature control","authors":"","doi":"10.61189/780603itrglq","DOIUrl":"https://doi.org/10.61189/780603itrglq","url":null,"abstract":"Radiofrequency ablation (RFA) represents a convenient, minimally invasive, and cost-effective approach for the treatment of small liver cancers measuring less than 3 cm in diameter. Nonetheless, the existing RFA techniques encounter challenges in precisely controlling the extent of ablation and the risk of overheating, which can lead to damage on the surrounding tissues. The ability to control the ablation area also plays a crucial role in the success of RFA procedures. To address these issues, we introduce a novel method that utilizes tumor boundary temperature monitoring to achieve precise control over the RFA process. Through the utilization of COMSOL Multiphysics simulation software, the proposed method was verified by comprehensive simulation and modeling and its efficacy in achieving regional control was testified. Subsequently, ex vivo experiments were conducted employing a custom-designed cooling RFA instrument. The experimental results demonstrated that the RFA controlled by boundary temperature yielded an ablation area with a diameter approaching 30 mm. In comparison to the standard spherical solidification zone (characterized by both the ellipticity and regularity indices of 1), the cooling RFA discoloration zone, under boundary temperature control, exhibited a maximum deviation of 7% in the ellipticity index and 17% in the regularity index. The average ellipticity index was determined to be 0.96, while the average regularity index was 0.86. Collectively, these findings underscore the capability of the proposed temperature-controlled cooling RFA method to attain precise control over the ablation area, contributing to comprehensive ablation of tumor tissue within the target region.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136366052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Approaches to enhance patient tolerance during gastrointestinal endoscopic examination: A literature review 提高胃肠内镜检查患者耐受性的方法:文献综述
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/945507zhvpwe
{"title":"Approaches to enhance patient tolerance during gastrointestinal endoscopic examination: A literature review","authors":"","doi":"10.61189/945507zhvpwe","DOIUrl":"https://doi.org/10.61189/945507zhvpwe","url":null,"abstract":"In recent years, the importance of endoscopic procedures has risen significantly in response to the escalating prevalence of digestive system diseases. The gastroenteroscopic technique has undergone several iteration and updates; however, challenges related to patient pain remain an ongoing concern. As a result, patients satisfaction with this examination method is still low. Based on this, research has been focusing on assistive technologies that work with endoscopy to increase patient tolerance. The technologies listed in this review inculde sedation, acupoint stimulation, recumbent changes, gas-filled assistance, warm water infusion assistance, and distraction.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136364463","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Progress on Kirschner wire insertion techniques for patellar fractures 髌骨骨折克氏针置入技术的研究进展
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/550253gnnvtv
{"title":"Progress on Kirschner wire insertion techniques for patellar fractures","authors":"","doi":"10.61189/550253gnnvtv","DOIUrl":"https://doi.org/10.61189/550253gnnvtv","url":null,"abstract":"Tension band wiring has been widely used in patellar fracture internal fixation. However, Kirschner wires (K-wires) insertion is time-consuming, because it requires multiple intraoperative fluoroscopies to adjust the insertion angle, and the accuracy of insertion is not ideal. In this review, we summarize the measurement of patellar anatomical parameters, K-wires placement level, and application of guiding devices, with the focus on improving the accuracy of K-wire insertion from perspectives of K-wire placement and guiding devices. This review hope to provide some inspiration for new guiding devices with auxiliary K-wire placement.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136364465","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A method for identifying pleural lines in B-mode ultrasound images 一种在b超图像中识别胸膜线的方法
Progress in Medical Devices Pub Date : 2023-06-30 DOI: 10.61189/594641kmfbkw
{"title":"A method for identifying pleural lines in B-mode ultrasound images","authors":"","doi":"10.61189/594641kmfbkw","DOIUrl":"https://doi.org/10.61189/594641kmfbkw","url":null,"abstract":"In ultrasound imaging, the pleura is visualized as echo reflection formed by the echoes of the interface between the pleura and the lung surface. Three major signs of pleura determines whether the patient has pneumothorax. In this paper, we propose a method to identify pleural line for the diagnosis of pneumothorax. Firstly, the gray threshold of ultrasonic image is properly classified by pre-experiment. Secondly, possible pleural line regions are identified based on threshold classification. Thirdly, the region of pleural line is identified based on the known characteristics of pleural line. The last step is to consider whether it is necessary to modify the threshold to accurately identify the pleural line region. Moreover, we tested 890 ultrasound samples, which included three categories: lung sliding, lung point, and lung sliding disappearance. Each category of samples was divided into two subsets, typical and atypical. The average identification rate reached 90.45%. According to the test results, the advantages and disadvantages of the proposed method as well as the further improvement direction were analyzed. This method for identifying pleural line can serve as the groundwork for developing automatic algorithm for diagnosing pneumothorax.","PeriodicalId":476834,"journal":{"name":"Progress in Medical Devices","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136365895","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书