{"title":"Effect of voltage reduction in minimising partial discharge activity in cables — Experimental study","authors":"F. P. Mohamed, W. H. Siew, B. Sheng, B. Stewart","doi":"10.1109/CEIDP.2017.8257515","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257515","url":null,"abstract":"A common cause of insulation degradation in high voltage (HV) cables is due to partial discharges (PD). PD may be initiated through imperfections and contaminants present in the insulation. It can be hypothesized that a reduction in system voltage can potentially reduce PD, which will correspondingly extend the service life of the cable. Currently, industry voltage statutory requirements permit ±6% tolerance setting on nominal voltage on distribution networks. Such ±6% voltage reduction on may have little or adverse effect on PD magnitude which depends on the nature of defect. Hence the accuracy and type of measuring PD while reducing system voltage is more critical for this application. Power cable as a low pass filter which attenuates and disperse the PD pulses. In this paper effect of voltage reduction on PD is investigated using standard electrode geometries such as point-plane, point-point and point- rod using IEC60270 measurement system together with frequency domain measurements. It has been observed that PD frequency characteristics at different voltages varies in the wideband frequency spectrum.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115913983","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhiqiang Xu, M. Hao, Bo Huang, George Chen, M. Praeger, P. Lewin
{"title":"Space charge dynamics and electric field distortion in the laminated insulation for HVDC cable","authors":"Zhiqiang Xu, M. Hao, Bo Huang, George Chen, M. Praeger, P. Lewin","doi":"10.1109/CEIDP.2017.8257642","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257642","url":null,"abstract":"Polypropylene laminated paper (PPLP) is an important composite insulation which has been successfully used in oil filled (OF) cable, mass impregnated (MI) cable and high temperature superconductor (HTS) cable. PPLP is an improved insulation based on conventional cellulose Kraft paper. It is made of one PP film sandwiched between two Kraft papers. The space charge distribution in DDB oil impregnated PPLP sample under DC electric field has been investigated by the pulsed electroacoustic (PEA) technique in this paper. The electric field distribution and distortion have been discussed based on the results obtained from one, two and three layers of PPLP sample. The results show that space charges start to accumulate at the interfaces between paper and PP with time. As a result, the electric field created by the accumulated space charge within the PP film has been enhanced while the electric field in paper reduced. The more the charge accumulated, the higher the electric field distortion in the PP film. The charge distribution and electric field distortion present repeatable pattern in multilayered PPLP sample.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125640745","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Condition monitoring of oil-filled transformers using unsupervised classification techniques","authors":"S. Eke, T. Aka-Ngnui, G. Clerc, I. Fofana","doi":"10.1109/CEIDP.2017.8257557","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257557","url":null,"abstract":"In this contribution, an automatic classification technique is used to monitor oil-filled transformers condition from maintenance data. The data collected from two groups of transformers are reported into an observation space. This space summarizes the information contained in a feature vector. This vector is filled with oil's aging indicator parameters namely the dielectric strength, the interferential tension, acidity and power factor. The TDCG (Total Dissolved Combustible Gas) is included to monitor incipient failure in the transformer. Two unsupervised classification methods are used: the K-means and Fuzzy C-means. The clusters included transformers with similar behavior to ease analyses.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114800871","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electric field measurement in liquid dielectrics using Kerr effect","authors":"Z. Zakaria, T. Andritsch, P. Lewin","doi":"10.1109/CEIDP.2017.8257627","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257627","url":null,"abstract":"Space charge has been known to affect the performance of the electrical insulation. Therefore, it is important to understand the information of the electric field and space charge distributions in the insulating materials in order to improve the electrical insulation of the electric power apparatus. The aim of this research is to investigate the electric field distribution in dielectric liquid using the Kerr effect method. In the current study, the parallel-plane was applied as the electrodes system in the Kerr experiment under DC electric field. The images of the light intensity of the transmitted light from the laser beam were recorded by a detector. From the experimental results obtained, the images between the incident light intensity and the transmitted light intensity were compared by using the image enhancement-arithmetic technique. With the absence of electric field, the light intensity was uniformly dark. By increasing, the electric field applied to the dielectric liquid, the intensity ratio of the incident light to the transmitted light increases too.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"775 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116414011","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On water absorption and its impact on the dielectric spectra of epoxy network with different stoichiometries","authors":"F. Alhabill, T. Andritsch, A. Vaughan","doi":"10.1109/CEIDP.2017.8257538","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257538","url":null,"abstract":"The effect of changing the resin/hardener stoichiometry on moisture absorption of an epoxy/amine network was investigated. The results indicate that decreasing the hardener content below the stoichiometric ratio leads to lower water uptake levels, whereas increasing it beyond the stoichiometric ratio has the reverse impact. Hence, in terms of water absorption, using epoxy-rich formulations might be beneficial. Dielectric spectroscopy measurements imply that the absorbed water molecules interact with the polar components of the matrix, which lowers the frequencies at which these water molecules relax. Analysis of the obtained spectra showed that a significant part of the absorbed water molecules relaxes in phase with the existing β relaxation, which implies that these water molecules are bounded to the polar moieties that are responsible for the β relaxation. The other part of the absorbed water relaxes at higher frequencies (> 1 MHz). Therefore, this part may be bound to other polar moieties that relax at frequencies higher than 1 MHz and/or may represent unbounded or ‘free’ water clustered within the free volume inside the epoxy matrix and, thus, exhibit a relaxation that is more similar to the relaxation of bulk water.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133253776","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electric field relaxation effect of Functionally Graded Materials (FGM) with conductive multilayer coating","authors":"R. O'ishi, H. Kojima, K. Kato, N. Hayakawa","doi":"10.1109/CEIDP.2017.8257494","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257494","url":null,"abstract":"For the insulation design of gas insulated power apparatus, the electric field grading and control are indispensable. We have proposed the application of σ-FGM (Functionally Graded Materials with spatial distribution of conductivity σ) to solid insulators as a novel technique of the electric field grading and control. In this paper, we fabricated the conductive multilayer coating for σ-FGM and investigated the electric field relaxation effect of σ-FGM on a GIS spacer surface. The fabrication results revealed that we could obtain the conductive 3-layer coating by using the dip coating method. The calculation results revealed the technical feasibility of electric field relaxation by σ-FGM with the conductive multilayer coating.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115160072","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. A. P. Ferreira, R. Altafim, Felipe Schiavon Inocencio de Sousa, T. Palitó, Y. Assagra, R. Altafim
{"title":"Detection of acoustic emissions from partial discharges in distribution transformers with piezoelectret transducers","authors":"D. A. P. Ferreira, R. Altafim, Felipe Schiavon Inocencio de Sousa, T. Palitó, Y. Assagra, R. Altafim","doi":"10.1109/CEIDP.2017.8257599","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257599","url":null,"abstract":"Transformers are critical equipment in electrical energy systems and their failure may lead to loss of power supply. Major problems are normally avoided by preventive maintenance and implementation of fault detection systems on power transformers. Some of these systems are based on Partial Discharge (PD) detection methods, since PD is known to be one of the main causes of failures in transformers, such as those intended to power distribution. However, due to the large amount of such equipment installed on distribution lines, these monitoring methods may become very expensive. In order to increase the reliability of the grid, distribution transformers have been receiving more attention. In this context, this paper presents a low-cost transducer based on thermoformed piezoelectrets to detect PD acoustic emissions in distribution transformers. PD were produced using point-plane electrodes placed inside the tank of a distribution transformer filled with mineral oil. The PD acoustic signals were detected by a R15I sensor and a thermoformed piezoelectret transducer, previously validated in the acoustic PD detection in the air gap point-point electrode configuration. The PD acoustic signals were processed to obtain two metrics: root-mean value voltage and frequency spectrum. Based on these metrics it was possible to establish a direct correlation between applied voltage and PD activity.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124778464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of interface on the electrical properties of silicone nanocomposites","authors":"Faisal Aldawsari, C. Angammana, S. Jayaram","doi":"10.1109/CEIDP.2017.8257645","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257645","url":null,"abstract":"The interface between filler and matrix affects the properties of nanocomposites because of the high ratio of surface area to volume of nano fillers. To understand the role of interface, silicone nanocomposites containing two different types of hydrophobic fumed silica with different specific surface areas of 160 and 260 m2/g in silicone rubber (RTV 615) matrix are investigated using frequency domain spectroscopy. The spectroscopy measurements are carried out in the frequency range of 10−4 to 103 Hz, at various excitation levels. Effects of filler concentration, filler surface treatment, and mixing method on the dielectric properties are investigated. The results show that the level of filler dispersion plays a major role in determining the effective permittivity and loss factor as it considerably alters the volume of interface region and bonding of fillers to the polymer.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"85 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123287689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Approach to measure of space charge distribution in alumina material using PEA method under DC electric stress","authors":"Masakazu Taira, T. Kurihara, H. Miyake, Y. Tanaka","doi":"10.1109/CEIDP.2017.8257511","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257511","url":null,"abstract":"In recent years, improvement of power density of a power semiconductor modules is required. However, it has been reported that dielectric breakdown occurs in the ceramic material used as an insulating substrate for the power semiconductor under the environment currently used. Therefore, to make it reliable and to improve its power density as the power module, it is necessary to elucidate the dielectric breakdown mechanism of the ceramic material. In this research, we tried to investigate the dielectric breakdown mechanism of the ceramic materials by measuring space charge accumulation characteristics using PEA method. However, it was found that the ceramic material a theoretically unexplainable behavior when shows it is measured using the PEA method. Therefore, we tried to estimate the charge behavior inside the ceramic material from a measurement result in multilayer samples composed of ceramic material and polymer material.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"31 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123721789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zengbin Wang, Hong Lv, Liuhuo Wang, Yilong Chen, Ying Tang, Z. Rao, Ji Wu, Shu-pin Liu, Hongyang Zhou, G. Ma, Shusheng Zheng, Chengrong Li
{"title":"Accumulative insulation characteristics of 110kV GIS spacer under repeated impulse voltages","authors":"Zengbin Wang, Hong Lv, Liuhuo Wang, Yilong Chen, Ying Tang, Z. Rao, Ji Wu, Shu-pin Liu, Hongyang Zhou, G. Ma, Shusheng Zheng, Chengrong Li","doi":"10.1109/CEIDP.2017.8257552","DOIUrl":"https://doi.org/10.1109/CEIDP.2017.8257552","url":null,"abstract":"During the factory inspection and service life, the Gas Insulated Switchgear (GIS) is continuously and unavoidably subjected to repeated impulse voltages, which may cause irreversible damage to the solid insulation. The impact of these repeated impulse voltages on the insulation performance of the spacer needs to be studied. In this paper, an experimental setup for appling impulse voltages repeatedly to spacers in 110kV GIS was built. The impact of repeated lightning and switching impulse voltages on the insulation performance of the spacer had been studied with clean condition. In addition, the impact of repeated lightning impulse voltages on the insulation performance of the spacer under metallic particle contamination had been also researched. Experimental results show that the accumulative effect of spacer under repeated impulse voltages is little, and the impact on the insulation performance of spacers in GIS on-site is little, whether in clean condition or small metal particle contamination. However, once the size of metal particle exceeds a certain length, the spacers will flash over directly under the possible occurrence of lightning impulse voltage in 110kV GIS on-site.","PeriodicalId":448901,"journal":{"name":"2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116570369","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}