Jingfen Bai, Lin Yang, Sha Zhao, Jianhua Zong, Eddy So
{"title":"The establishment of reactive power/energy standard at China electric power research institute and its comparison with NRC","authors":"Jingfen Bai, Lin Yang, Sha Zhao, Jianhua Zong, Eddy So","doi":"10.1109/CPEM.2010.5544814","DOIUrl":"https://doi.org/10.1109/CPEM.2010.5544814","url":null,"abstract":"A reactive power standard, based on the current comparator power bridge, established at CEPRI, for calibrating active/reactive power/energy meters under sinusoidal conditions is described. It allows calibration of active/reactive power and energy meters at voltages between 60 V to 600 V and currents between 0.1 A to 200 A, any power factor from zero lag through unity to zero lead, and test frequencies of 45 Hz to 65 Hz. The Type B uncertainty of the reactive power standard is estimated to be 30 µvar/VA at k = 2. A comparison of reactive power meter calibrations between CEPRI and NRC will also be presented and discussed, including the sources of errors and corresponding uncertainties.","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115441874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Precision measurements using laser cooled atoms","authors":"S. Chu, M. Kasevich, K. Moler, E. Riis, D. Weiss","doi":"10.1109/CPEM.1990.109897","DOIUrl":"https://doi.org/10.1109/CPEM.1990.109897","url":null,"abstract":"A number of experimental applications of laser cooling of neutral atoms are described. In an experiment on atomic fountains, laser-cooled atoms pushed up on a vertical trajectory by radiation pressure were observed to turn around due to gravity. A compact cesium fountain that would give three to four orders of magnitude increase in the counting rate over the first experiment can be designed, and the trapping and cooling can be done with diode lasers, suggesting a practical clock. In order to increase the time-averaged flux of such a fountain and also create a continuous fountain, an atomic funnel that can produce an atomic beam of very low velocity ( approximately 270 cm/s) at densities of 10/sup 8/ atoms/cm/sup 2/ has been devised.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123126581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Stuchly, D. Gibbons, A. Thansandote, H. LePocher
{"title":"Magnetic field sensor for measurements of transients","authors":"M. Stuchly, D. Gibbons, A. Thansandote, H. LePocher","doi":"10.1109/CPEM.1990.109983","DOIUrl":"https://doi.org/10.1109/CPEM.1990.109983","url":null,"abstract":"The basic principles, design, and testing of a magnetic field sensor based on an electrically small loop are reported. A sensor comprising a single-turn loop, current transformer, and broadband amplifier was modeled using the SPICE simulation program. A sensor was designed to operate from approximately 5 kHz to 100 MHz. It consists of a square loop with a total length of 24 cm and a wire diameter of 1.3 mm. The ferrite transformer has mu =850, n=25. The computer simulation and test results are presented and are in good agreement.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116674741","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Krisher, L. Maleki, G. Lutes, L. Primas, R. Logan, J. D. Anderson, C. Will
{"title":"A new test of relativity using hydrogen maser standards","authors":"T. Krisher, L. Maleki, G. Lutes, L. Primas, R. Logan, J. D. Anderson, C. Will","doi":"10.1109/CPEM.1990.109991","DOIUrl":"https://doi.org/10.1109/CPEM.1990.109991","url":null,"abstract":"A novel test of relativity that was performed using advanced time and frequency technology of the Deep Space Network is discussed. The instrumentation, procedure. and data analyses are described. By directly measuring the propagation-delay variation between two masers, limits on a possible anisotropy in the one-way velocity of light have been obtained.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"55 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125672572","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A time-domain method for the accurate characterization of linear systems","authors":"C. Narduzzi, C. Offelli","doi":"10.1109/CPEM.1990.109932","DOIUrl":"https://doi.org/10.1109/CPEM.1990.109932","url":null,"abstract":"The characterization of a linear system from input/output measurements is addressed. The use of wideband test waveforms and of a fast time-domain constrained-least-squares algorithm is described. The accuracy of the method is analyzed, and possible applications are outlined.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"75 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122540416","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A novel audio-frequency compensation circuit for precision measurement","authors":"Fei Zheng-Sheng","doi":"10.1109/CPEM.1990.110057","DOIUrl":"https://doi.org/10.1109/CPEM.1990.110057","url":null,"abstract":"A novel frequency compensation circuit which may be used for precision measurement is proposed. This circuit can reduce the residual error at audio frequency. A formula for maximum residual error is derived and studied.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"393 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114504994","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A geometrical approach to the quantized Hall effect (for use in metrology)","authors":"C. Peters","doi":"10.1109/CPEM.1990.110048","DOIUrl":"https://doi.org/10.1109/CPEM.1990.110048","url":null,"abstract":"A very rudimentary phenomenological model of the QHE (quantized Hall effect) is proposed. It is based on a semiclassical approximation which, although not rigid in a theoretical sense, gives some insight into the geometrical parameters involved in the QHE and, by its semiclassical character, provides an interpretation of the operators involved in the theory of the QHE. The model gives most of the observable features of the integral QHE. The influence of the finite width of the sample as well as the current and temperature dependence can be taken into account using the model. Although the model fails in fitting the fractional effect and it has to be used with great care above the critical current since no interband transitions have been taken into account, it could prove useful for the classification of samples for metrological use. For example, the expressions indicate that both the magnetic and the electrical mobility are important for classifying a sample's quality.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126794264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Hartland, K. Jones, J.M. Williams, M. Davies, B. Gallagher, T. Galloway, M. Henini, O. Hughes
{"title":"High accuracy measurements of quantized Hall resistance ratios R/sub K/(i)/R/sub K/ (2i) for i=1 and 2 in GaAs and silicon","authors":"A. Hartland, K. Jones, J.M. Williams, M. Davies, B. Gallagher, T. Galloway, M. Henini, O. Hughes","doi":"10.1109/CPEM.1990.110052","DOIUrl":"https://doi.org/10.1109/CPEM.1990.110052","url":null,"abstract":"Indirect measurements of the quantized Hall resistance of three GaAs devices confirm that within a combined relative uncertainty (1 sigma ) of about 15 parts in 10/sup 9/, the ratio R/sub K/(i)/R/sub K/ (2i) for i=1 and 2 is exactly 2. A cryogenic current comparator bridge has been constructed to compare directly R/sub K/(2) in GaAs and R/sub K/(4) in Si with a relative uncertainty of 1 part in 10/sup 9/.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"114 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123344323","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Determination of the volt with the improved PTB voltage balance","authors":"T. Funck, V. Sienknecht","doi":"10.1109/CPEM.1990.109980","DOIUrl":"https://doi.org/10.1109/CPEM.1990.109980","url":null,"abstract":"Determinations of the conversion factor of the volt have been carried out after significant improvements to the measuring system. The mean value of 48 determinations was K/sub V/=1-0.02*10/sup -6/, with a standard deviation of the mean s/sub m/=0.064*10/sup -6/. The corresponding frequency-to-voltage quotient is K/sub J/=483597.91 GHz/V. The relative type B uncertainty of the experiment was estimated to be u=0.33*10/sup -6/. These data are preliminary, in as much as the recalibration of the standards used for the capacitance, the mass, and the displacement in terms of the SI units farad, kilogram, and meters had not yet been carried out.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116183148","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance of new hydrogen masers at the National Research Council of Canada","authors":"D. Morris","doi":"10.1109/CPEM.1990.110008","DOIUrl":"https://doi.org/10.1109/CPEM.1990.110008","url":null,"abstract":"Two active hydrogen masers designed to be operated as clocks and as contributors to the National Research Council of Canada (NRC) time scale have been constructed. Details of their design are presented together with some initial measurements of line-Q and frequency stability. A plot of maser power as a function of linewidth for maser H4 is shown. The experimental values of linewidth at the extremes of the oscillation curve correspond to line-Q values of 6.1*10/sup 9/ and 1.3*10/sup 9/, respectively. At a reasonable operating atom flux, the line-Q is 4*10/sup 9/, which is a factor of two better than that obtained for maser H1 at its normal operating flux. Some initial measurements of the frequency stability of the masers have also been made.<<ETX>>","PeriodicalId":447833,"journal":{"name":"Conference on Precision Electromagnetic Measurements","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125796656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}