2010 Advanced Technologies for Enhancing Quality of Life最新文献

筛选
英文 中文
A 3D ECM-Mimicking Device to Assess Stem Cells Differentiation: A Novel Approach to Stemness Evaluation 一种用于评估干细胞分化的三维ecm模拟装置:一种新的干细胞评估方法
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.18
A. Rainer, C. Spadaccio, S. De Porcellinis
{"title":"A 3D ECM-Mimicking Device to Assess Stem Cells Differentiation: A Novel Approach to Stemness Evaluation","authors":"A. Rainer, C. Spadaccio, S. De Porcellinis","doi":"10.1109/ATEQUAL.2010.18","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.18","url":null,"abstract":"Stem cell therapy is considered a leading field of research worldwide, attracting a stunning amount of clinical applications, given its promising potential for recovery or replacement of tissues and organs. The idea of combining principles from cell biology and engineering of biocompatible materials in order to create biologic replacement structures that restore, maintain, or improve tissue function, is at the basis of the so called “Tissue Engineering” area, a new emerging avenue in regenerative medicine. On account of the more demanding requirements for the use of stem cells in clinical settings and of the constant description of new stem cells types, the authors developed a functional biological assay, based on 3D ECM-mimicking supports, for the assessment of differentiative potential of candidate bone marrow-derived cells towards chondrocytic, vascular and muscular phenotypes.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115687976","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Controversies in Large Metal-on-Metal Cementless Total Hip Arthroplasty 大型金属对金属无骨水泥全髋关节置换术的争议
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.36
P. Botez, C. Stoica, P. Sîrbu, R. Asaftei, C. Grierosu
{"title":"Controversies in Large Metal-on-Metal Cementless Total Hip Arthroplasty","authors":"P. Botez, C. Stoica, P. Sîrbu, R. Asaftei, C. Grierosu","doi":"10.1109/ATEQUAL.2010.36","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.36","url":null,"abstract":"Over the last several years, many orthopaedic surgeons have embraced so-called alternative bearing surfaces in total hip arthroplasty, largely on the basis of the hypothesis that a reduction in the volumetric wear rates afforded by these improved articulating couples will reduce the prevalence of osteolysis and aseptic loosening, which in turn will improve implant survivorship. We conducted the study on an interval of 12 months. 19 cement less total hip arthroplasty using a metal-metal friction couple were consecutively implanted in 19 patients (6 female and 13 male) less than 55 years of age. We compared the reasults with a matched control group of cement less arthroplasties using ceramic-on-ceramic and metal - polyethylene articulation. The Harris hip score at follow-up (minimum 2 years) for the metal-on-metal was 95. After the same follow-up, the results of the ceramic-on-ceramic and polyethylene-metal were significantly different. With the same survival rates for both groups, the functional results (range of motion, stability and postoperative recovery) were significant increased for metal-on-metal bearing. In conclusion, we recommend this type of prosthesis for younger patients with an increased activity level, and a good quality bone stock., The position of the prosthetic cup is an important factor in the release and increased blood levels of metal ions. There are concerns regarding possible toxic effects of metal ions on pregnancy and hypersensitivity to metal ions. A greater follow-up and a greater setback are required to confirm the literature data, mostly encouraging.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128222794","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Increased Bioactivity of Cranio-spinal Implants Functionalized with Hydroxyapatite Nanostructured Coatings: Morpho-structural Characterization and In-Vitro Evaluation 羟基磷灰石纳米涂层增强颅骨-脊柱植入物生物活性:形态结构表征和体外评价
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.27
L. Duta, G. Socol, F. Sima, I. Mihăilescu, G. Stan, D. Marcov, L. Sima, S. Petrescu, A. Melinescu, A. Ianculescu, A. Chiriac, I. Poeată
{"title":"Increased Bioactivity of Cranio-spinal Implants Functionalized with Hydroxyapatite Nanostructured Coatings: Morpho-structural Characterization and In-Vitro Evaluation","authors":"L. Duta, G. Socol, F. Sima, I. Mihăilescu, G. Stan, D. Marcov, L. Sima, S. Petrescu, A. Melinescu, A. Ianculescu, A. Chiriac, I. Poeată","doi":"10.1109/ATEQUAL.2010.27","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.27","url":null,"abstract":"We report on the versatility of pulsed laser deposition and radio frequency magnetron sputtering deposition methods to synthesize highly adherent bioactive hydroxyapatite thin layers on cranio-spinal implants as appropriate biofixation alternatives.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132462995","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Experimental Study Regarding the Comparative Behavior of Three Osteoconductive Bone Graft Substitutes 三种骨导电性骨移植材料性能比较的实验研究
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.24
P. Sîrbu, R. Asaftei, M. Danciu, R. Mihăilă, L. Simion, C. Cotrutz, T. Petreuș, P. Botez
{"title":"Experimental Study Regarding the Comparative Behavior of Three Osteoconductive Bone Graft Substitutes","authors":"P. Sîrbu, R. Asaftei, M. Danciu, R. Mihăilă, L. Simion, C. Cotrutz, T. Petreuș, P. Botez","doi":"10.1109/ATEQUAL.2010.24","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.24","url":null,"abstract":"The aim of this study is to reveal the integration, bone reaction and and extent of osseous healing for 3 types of osteoconductive graft substitutes used on experimental bone defects performed in rabbit femurs. The authors have performed an in vivo study on 2 groups of 6 rabbits with induced bone defect in distal femoral epiphysis. There have been used 3 types of BGS: Eurocer 400 (FH Orthopedics) – a biphasic BGS (55% hydroxyapatite and 45% tri-calcium phosphate), as granules, Euro bone (FH Orthopedics) an injectable BGS (55% bi-calcium phosphate and 45% tri-calcium phosphate), Osteoset (Wright) – calcium sulphate BGS as pellets. The bone defect in the first group was filled with Eurocer400 on the right femur and with Osteoset in the left femur. In the second group, the bone defect on the right femur was filled with Eurobone and the left femur with Eurocer400. The rabbits were sacrificed at 2 months after bone graft implantation and radio logic and histological examination were performed. Periimplant bone fragments were cut, processed and decalcified. Serial sections were stained by hematoxylin-eosin and van Gieson tehcnique. X-ray examination showed a good Osseo integration for Eurocer and Eurobone. The 2 main disadvantages of Osteoset pellets are the poor biological integration and fast resorbtion. However, we have remarked a poor density of the material at 2 months post-implantation, with important fragmentation at the implantation place. Eurocer and Eurobone showed a good Osseo integration with new bone formation. Osteoset pellets must be reserved to cavity defects with small contact area with fluid, thus avoiding the BGS to dissolve too fast. However, calcium sulphate Osteoset can be used as carrier for antibiotics, as well as of bone inductive molecules.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132700947","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Muscle Reconstruction and Regeneration Using Biodegradable Scaffolds 利用可生物降解支架进行肌肉重建和再生
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.19
C. Spadaccio, A. Rainer, S. De Porcellinis, F. De Marco, M. Chello, M. Trombetta, J. Genovese
{"title":"Muscle Reconstruction and Regeneration Using Biodegradable Scaffolds","authors":"C. Spadaccio, A. Rainer, S. De Porcellinis, F. De Marco, M. Chello, M. Trombetta, J. Genovese","doi":"10.1109/ATEQUAL.2010.19","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.19","url":null,"abstract":"The complete loss or weakening of anatomically defined muscular structures may be determined by many pathological states and may lead to high morbidity and clinical expense. Attempts to functionally correct them have encountered limited success. On the account of more demanding requirements of materials for the myofascial repair, we evaluated a bioabsorbable polymer mimicking, at the structural level, the characteristics of the native extra cellular matrix (ECM). A described model of muscle injury was used, consisting in the generation of a large abdominal wall defect in 20 Wistar rats. Ablated rectus abdominis was repaired with electro spun poly-L-lactide (PLLA) acellullar patch. Evaluation of the newly developed ECM showed a more delicate fibrillar and organized collagen network in the PLLA group in comparison to control indicating a more advanced process of wound remodeling and a more controlled and modulated tissutal reaction. Scaffold elicited a potent angiogenic response with the appearance of CD31 positive vessels. Additionally, the graft hosted CD34 positive cells, reliable sign of organism response to muscle injury. The biomimesis principle inspiring the structure of this scaffold guided a reparative processes and modulated the microenvironment of the damaged tissue, favoring the regenerative drive over the inflammatory reaction.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"113 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126129879","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Biomaterials for Tissue Engineered Scaffolds 组织工程支架的生物材料
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.7
K. Pramanik
{"title":"Biomaterials for Tissue Engineered Scaffolds","authors":"K. Pramanik","doi":"10.1109/ATEQUAL.2010.7","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.7","url":null,"abstract":"In recent years the development of tissue engineered scaffolds from biodegradable polymers has been advancing because of their use as support material for tissue regeneration. This paper describes the various ideal biopolymers and their essential characteristics to suitable for tissue engineering applications. The functional characteristics of biomaterial include the optimization of porosity, wet ability, biocompatibility, surface topology and mechanical property to mimic the ECM function. The scaffold can be designed and fabricated by porogen leaching, thermally induced phase separation, emulsion polymerization, electro spinning and SFF for designing of 3-D scaffolds. Surface modification of scaffold is important to improve their mechanical and chemical properties which can be achieved by suitable chemical and/or irradiation. The scaffold must be biocompatible in order to provide the proper microenvironment for tissue-scaffold interaction. A brief of the ongoing research in the area of scaffold development for bone and cartilage tissue repair is also described.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117326319","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Mosaicplasty: A Good Alternative for Restoring Focal Chondral Defects of the Knee 镶嵌成形术:修复膝关节局灶性软骨缺损的良好选择
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.20
V. Predescu, Ș. Cristea, F. Groșeanu, V. Stoian, C. Prescura
{"title":"Mosaicplasty: A Good Alternative for Restoring Focal Chondral Defects of the Knee","authors":"V. Predescu, Ș. Cristea, F. Groșeanu, V. Stoian, C. Prescura","doi":"10.1109/ATEQUAL.2010.20","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.20","url":null,"abstract":"Management of articular cartilage defects is still one of most challenging problems between orthopedic surgeons. There are some methods which are claiming to restore cartilage around defects but none is capable to restore 100% hyaline cartilage. It is well known that hyaline cartilage has a poor intrinsec capacity of healing and damage from knee trauma or degeneration results in pain and functional impairment. Important untreated cartilage lesions can lead to debilitating joint pain and degenerative arthritis. There are a lot of techniques used to solve this problem. One of these is transplanting hyaline cartilage from a non weight bearing area of the knee joint to the defect situated in weight bearing area. This consists in harvesting multiple small cylindrical autogenousosteocondral plugs from periphery of cartilage and resurfacing the osteocondral defect. (Mosaicplasty or OATS). This technique developed initially by Hangody it is widely used now.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115777010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Influence of the Lattice Structures on the Mechanical Behavior of Hip Endoprostheses 晶格结构对人工髋关节力学行为的影响
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.16
Ghiba Mihai Ovidiu, T. Mirela, Prejbeanu Radu, Vasile Dinu
{"title":"Influence of the Lattice Structures on the Mechanical Behavior of Hip Endoprostheses","authors":"Ghiba Mihai Ovidiu, T. Mirela, Prejbeanu Radu, Vasile Dinu","doi":"10.1109/ATEQUAL.2010.16","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.16","url":null,"abstract":"Rapid Prototyping technologies allow fabrication of lattice structures made of biocompatible materials. The natural stress distribution in the femur is altered after total hip arthroplasty (THA) because the hip end prosthesis will assume a part of the load causing a reduction of stresses in some regions of the bone. This phenomenon is known as stress shielding and it results in a loss of bone mass. The bone will become less dense and weaker and the end prosthesis can become loosening. This study explores the assumption that insertion of a certain lattice structure into the hipendoprosthesis stem will lead to a more flexi bleendo prosthesis, but strong enough to support the natural hip joint forces. A more flexible end prosthesis will stimulate the bone to a correct remodeling. This structure can also offer a better osteointegration than the existing end prostheses. The presented study considers five different types of lattice structures that are inserted into a large area of the implant stem. There was analyzed both the possibility of using one type of lattice structure and a combination of two different types. The paper also presents some design aspects of the lattice structures and results of the numerical analyses performed in order to evaluate the mechanical behavior of the proposed end prostheses. The comparison of the results obtained by Finite Element Analysis (FEA) highlights the influence of the lattice structures type on the mechanical behavior of hip end prostheses.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133825505","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Biomechanical Analysis of Three Different Types of Implants in Humeral Diaphysis Fractures 三种不同类型肱骨骨干骨折植入物的生物力学分析
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.35
R. Asaftei, P. Sîrbu, E. Carata, M. Bar, P. Botez
{"title":"Biomechanical Analysis of Three Different Types of Implants in Humeral Diaphysis Fractures","authors":"R. Asaftei, P. Sîrbu, E. Carata, M. Bar, P. Botez","doi":"10.1109/ATEQUAL.2010.35","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.35","url":null,"abstract":"Objective: The purpose of this study was to evaluate the mechanical behavior of three different types of implants used in the osteosynthesis of comminuted humeral shaft fractures. Materials and methods: We used 16 Sawbones® composite synthetic bones. We created a medial third osteotomy and we removed a 38mm thick fragment. We instrumented the fractures with 3 types of implants: an intramedulary nail, two types of locked plates and a “classic” DCP. All of them were submitted to torsion essays in external and internal rotation as to obtain the same amount of torque. The loading-deforming diagrams were compared and statistically analysed for each type of implant. Conclusions: The shorter locked plate (LCP-Synthes®) seems to be the most rigid implant for each type of loading essay, the mean values of the loading forces being the highest in the entire group. The intramedullary nail proved to be the most elastic implant on all types of loading. In external rotation, the DCP gives surprisingly values of torsion forces relatively close to the longer locked plate (AxSOS - Stryker®). This seems to be related to the different “working length” of the different plates and also to the different total length of the implants.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130768031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Cryopreservation in Tissue Engineering: Challenges & Prospects 组织工程中的低温保存:挑战与展望
2010 Advanced Technologies for Enhancing Quality of Life Pub Date : 2010-07-15 DOI: 10.1109/ATEQUAL.2010.8
S. Sarangi, K. Pramanik
{"title":"Cryopreservation in Tissue Engineering: Challenges & Prospects","authors":"S. Sarangi, K. Pramanik","doi":"10.1109/ATEQUAL.2010.8","DOIUrl":"https://doi.org/10.1109/ATEQUAL.2010.8","url":null,"abstract":"This paper describes the prospects and challenges of cry preservation of tissue and tissue engineered products for their application to tissue repair and regeneration. The various aspects of cry preservation include optimization of cell specific freezing parameters such as cooling rate, type and concentration of cry oprotective agents (CPA), media, treatment methods, warming and thawing for the preservation of tissue and tissue engineered products. The key issues related to the cry preservation of tissue engineered constructs have been addressed explaining the occurrence of physicochemical and biophysical phenomena during cry preservation, heat and mass transfer limitation and effect of large size of constructs on toxicity and cell viability. It has been described the effect of ice-forming and ice-free cry preservation on cell viability, control of ice crystal formation by anti-freezing agent and cry preservation equipments. A brief of ongoing research on cry preservation of MNCs containing he matopoieticstems cells isolated from cord blood has also been presented.","PeriodicalId":444480,"journal":{"name":"2010 Advanced Technologies for Enhancing Quality of Life","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127047202","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书