{"title":"Operating Experience with the R.P.I. Linac","authors":"E. R. Gaerttner, M. Yeater, R. Fullwood","doi":"10.1109/TNS2.1962.4316060","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316060","url":null,"abstract":"The R.P.I. Linac, one of the most powerful electron accelerators in the world, has been in operation for several months. It has been operated at 130 megawatts peak power and at average beam power of 50 kilowatts for sustained runs. Evidence of pulse shortening has been observed only at currents of 0.8 ampere for pulse widths of 4.6 microseconds. A detailed discussion of performance is presented as well as current improvements.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128653547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design Considerations for Maximum Bandwidth in Transistorized Pulse Amplifiers","authors":"C. Williams, J. H. Neiler","doi":"10.1109/TNS2.1962.4316057","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316057","url":null,"abstract":"Each of the transistor biasing configurations - common-emitter, common-base, and common-collector - has disadvantages which greatly limits the use of cascaded, single-transistor stages for general wide-band amplification. Careful choice of a combination of biasing configurations in a single stage permits optimum use of the advantages of each configuration while minimizing the effects of the disadvantages. Considerations leading to the design of an acceptable wide-band pulse amplifier stage are discussed. These principles have been applied to the design of a one-stage feedback amplifier, which has the following characteristics: gain = 25.8 db, rise time = 2.8 nsec, and linear amplification of either positive or negative pulses.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116444799","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Measurement of Gamma Dose with Silicon Junction Counters","authors":"A. R. Jones","doi":"10.1109/TNS2.1962.4316059","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316059","url":null,"abstract":"Measurements have been made on three types of silicon Junction counters to assess their application in gamma ray dosimetry. These measurements are presented and it is concluded that each of the three types (high resistivity and guard-ring p-n junction counters and lithium drift counters) are suitable. Their limitations and means of application are also discussed.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126144781","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"BF3 Counter Background Study","authors":"O. Bilharz","doi":"10.1109/TNS2.1962.4316062","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316062","url":null,"abstract":"An evaluation of spurious, nonneutron, background counts from BF3 proportional counters has been made. This evaluation indicates that the source of ionization events within the counters is from alpha particles originating in natural uranium series bulk contamination of the counter materials. This leads to an irreducible minimum background counting rate in the absence of rfeutrons which is characteristic of each individual counter. Measurements on a number of commercial counters gave backgrounds of from 0.005 to 0.05 cpm per square inch of inner surface. Careful materials selection and special processing techniques should reduce this source of background considerably.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114625067","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High Accuracy Low Digital Integrator","authors":"Isroel Pelah, D. Maydan","doi":"10.1109/TNS2.1962.4316061","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316061","url":null,"abstract":"A semiconductor current digital integrator is described for measuring currents as low as 10-9, amps with an accuracy better than 0.02% and a dynamics of 104. This is accomplished by Comparing two currents by means of a two-channel instrument. Using only one of the channels, the accuracy is 0.1% and the dynamic range is 105.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"108 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115157166","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Redundant Pulse Amplifier","authors":"T. A. Somer","doi":"10.1109/TNS2.1962.4316058","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316058","url":null,"abstract":"A redundant transistorized pulse amplifier is described, composed of a remote preamplifier operating at -80°C and a main pulse amplifier. Active parallel redundancy is used in the preamplifier as well as in the main amplifier. Common feedback between the parallel redundant amplifiers stabilizes the voltage amplification in spite of component failures in one signal path. Delay-line pulse shaping is employed to reduce noise and to eliminate the detrimental effects of pulse pile-up.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125970978","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Components and Application Techniques for Electronic Circuitry Operating in Nuclear Environments","authors":"L. T. Bowles, J. Crittenden, E. L. Davis","doi":"10.1109/TNS2.1962.4316038","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316038","url":null,"abstract":"A discussion is presented of the effects of steady-state, pulsed, and natural space radiation on electronic equipment. The effects of steady-state irradiations of various active and passive circuit element materials with up to 1020 nvt of fast neutrons and 1012 r of gamma rays are outlined. The effects of gamma pulses of about 100 to 107 r/sec on the responses and properties of circuit elements are discussed. The effects of dose rate on conductivity of various insulators is shown at several temperatures. The nature of space radiations is considered.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121089887","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Statistics of Zero Power Nuclear Reactors","authors":"R. Albrecht","doi":"10.1109/TNS2.1962.4316037","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316037","url":null,"abstract":"In a zero power nuclear reactor operating in steady state fluctuations in the neutron population about the average neutron population are observable. These fluctuations are related to the dynamic parameters of the reactor and may be of interest in measurements of dynamic parameters or in the analysis of sensitive experiments in which the characteristics of this population fluctuation are important. In this paper equations are developed for the autocorrelation function and the power spectral density function for zero power, point reactor fluctuations. An equation is also derived for the ratio of the variance to the mean of the integrated value of the noise as a function of time interval. The derivation of these equations uses the concepts of noise analysis common to optimum design theory. The effects of delayed neutrons and of source neutrons are included. A typical experimental curve for the variance to mean ratio taken on the Ford Nuclear Reactor at the University of Michigan is shown which displays the form of this function.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128416498","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nuclear Pulse Current-Sensitive Amplifiers","authors":"I. M. Meth, R. T. Graveson","doi":"10.1109/TNS2.1962.4316040","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316040","url":null,"abstract":"The development of current sensitive feedback amplifiers and their application to nuclear instrumentation is described and is exemplified by a non-overloading amplifier stage. Characteristics of this stage include a stage gain of 40, a loop gain of 250, a rise time of 0.2 μsec, and an input resistance of six ohms. Specific applications include a linear current discriminator, current to voltage converters, charge integrators and delay line shapers. A review of feedback theory and design equations is included.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"111 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134092644","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Tramsistorized Reactivity Computer","authors":"R. Shea","doi":"10.1109/TNS2.1962.4316042","DOIUrl":"https://doi.org/10.1109/TNS2.1962.4316042","url":null,"abstract":"The usual reactor kinetics equations are shown to consist of three major camponents, a fast term; a product or quotient, and a summation of transient terms. These can be synthesized by using a number of simple R.C. networks having time constants related to the fast time constant and to the decay constants of the various groups of delayed neutron emitters, plus either an analog multiplier or divider. If an input signal proportional to neutron flux or reactor power is applied to this network, the output will be proportional to reactivity. A circuit is shown which incorporates these principles, using a diode divider. Curves are presented of output reading, indicating transient reactivity, for input currents having constant positive period, as obtained from a motor-driven potentiometer. It is shown that these curves are in reasonable agreement with calculated curves of reactivity for such periods.","PeriodicalId":442703,"journal":{"name":"IRE Transactions on Nuclear Science","volume":"91 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1962-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134240912","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}