S. Manoj Kumar, B. S. Deepak Sagar, V. Prema, A. Anil Chandra, Bavikar Suhas
{"title":"Modelling and Simulation of Bifurcated Winding Induction Generator using 3DEXPERIENCE","authors":"S. Manoj Kumar, B. S. Deepak Sagar, V. Prema, A. Anil Chandra, Bavikar Suhas","doi":"10.1109/gpecom55404.2022.9815785","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815785","url":null,"abstract":"The rising demand for the use of non-conventional energy sources mandates new and improved approaches for wind energy conversion systems. Bifurcated winding induction machine (BWIG) is one such idea proved to be well-suited for wind power generation due to the constant frequency operation. This paper develops a complete mathematical and simulation model of BWIG machine using Dassault Systemes 3DEXPERIENCE platform. The equivalent diagram of the machine is developed and the electrical simulation model is developed with Dymola Behavioral Modeling platform. The machine is analysed for different operating conditions such as varying excitation voltages, varying operating speeds and load conditions.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131221187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dual Wideband Millimeter-Wave Stacked Cylindrical-Rectangular DRAs for 5G Applications","authors":"Farah S. Hasan, Saja R. Aldebes, Yanal S. Faouri","doi":"10.1109/gpecom55404.2022.9815634","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815634","url":null,"abstract":"In this paper, a dual wideband dielectric resonator antenna is proposed for millimeter-wave application. Bandwidth enhancement methods were used to configure the proposed antenna characteristics. The DRA consists of several dielectric resonators to form a special shape. The designed antenna is installed on a grooved ground and built from different dielectric materials. Two wide bands were achieved, the first band ranging (24.2 – 31.33) GHz with fractional bandwidth of 25.7 %, and the second band covers (34.75 – 41.03) GHz with fractional bandwidth of 16.57 %. This result makes the DRA applicable for (28 and 38) GHz millimeter-wave bands for 5G applications.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"142 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132431571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Delay Margin Computation of Generator Excitation Control System with Incommensurate Time Delays Using Critical Eigenvalue Tracing Method","authors":"Ö. Aydın, Şahin Sönmez, S. Ayasun","doi":"10.1109/gpecom55404.2022.9815801","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815801","url":null,"abstract":"This study investigates the effect of incommensurate time delays on the stability of the generator excitation control system. Unlike studies in the literature, the delay-dependent stability analysis is performed for cases where time delays in the feedback and feedforward loops of the generator excitation control system are independent of each other. The delay margin values are calculated by using the eigenvalue tracing method. The technique obtains critical eigenvalues on the imaginary axis in line with the eigenvalue loci of a transformation matrix in order to obtain stability regions in a two-dimensional delay space. It is found that the stability of the generator excitation control system deteriorates for delays outside the stability region. The accuracy of stability boundary is verified by time-domain simulations and Quasi-Polynomial Mapping Based Rootfinder (QPmR) algorithm.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114412780","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Experimental Impact Analysis of the Refrigerator Cable Design On Disturbance Power Test","authors":"Firat Araz, Gokturk Poyrazoglu","doi":"10.1109/gpecom55404.2022.9815571","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815571","url":null,"abstract":"The ever-increasing variety of electronic products brings with it many tests and controls. Especially for a product such as a refrigerator, which has an important place in the lives of users and works non-stop for almost its entire life, all compatibility tests that may affect the end-user must be carried out. Electromagnetic compatibility (EMC) tests are the most critical of these tests. In this study, the effect of the disturbance power test, one of the EMC tests, on the changing properties of the product was investigated. The effect of three different cable structures used in the refrigerator on the disturbance power test was investigated. These tests are carried out to cover 10 different frequencies in three products using different cable structures. Tables containing the oscilloscope results of these tests and the margin values corresponding to the frequencies are included in the document. In addition, visuals containing the differences between each cable structure and cable have been added. The results and analyzes of these tests are included in the report.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114800017","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Ivanov, B. Safronov, Alexander Ryzhkov, A. Voloshin
{"title":"Development of a mobile network scanner-analyzer of the local area network of a digital substation for the analysis of flows of the IEC 61850 standard to improve the reliability of a digital substation","authors":"A. Ivanov, B. Safronov, Alexander Ryzhkov, A. Voloshin","doi":"10.1109/gpecom55404.2022.9815688","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815688","url":null,"abstract":"This article presents the process of developing a mobile network scanner of information flows of the IEC 61850 standard for use at a digital substation. The network scanner is an autonomous device that must be connected to the local computer network of a digital substation to perform network analysis. The network scanner receives power from the network equipment of the digital substation. The scan results are provided using a Wi-FI network generated by the scanner itself. The user needs to connect to the scanner's Wi-FI network and use the scanner's functions using the user interface: analysis of SV (Sampled Values) streams and GOOSE (Generic Object-Oriented Substation Event) messages, analysis of the load of the local computer network, viewing errors, viewing the characteristics of network protocols. The scanner interface is designed in the user-friendly concept and the layouts of the network scanner are presented in this paper. During testing of the network scanner software, a problem was discovered – insufficient performance on devices with low processor power. In this regard, the article presents the tools for solving this problem and the results of the network scanner software on the Raspberry Pi 4b minicomputer.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116905816","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Danilov S. A, V. A., V. A., Kovalenko A. L, Degtiarev D. A, Sazanov V. S
{"title":"The System of Automatic Adaptive Change of Relay Protection Operation Parameters in Distribution Networks","authors":"Danilov S. A, V. A., V. A., Kovalenko A. L, Degtiarev D. A, Sazanov V. S","doi":"10.1109/gpecom55404.2022.9815781","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815781","url":null,"abstract":"This paper presents mathematical and logical methods implemented as computer programs that calculate the parameters of the operation of relay protection devices. The developed algorithms and software modules make it possible to automatically calculate the response parameters of relay protection devices that implement the functions of three-stage current protection against phase-to-phase short circuits. For the correct transmission of setpoints in accordance with the requirements of the IEC 61850 standard, an electronic documentation file (Configure parameters description) has been developed, containing a description and values of the device response parameters, and the sequence of transmission of setpoints to relay protection terminals has been determined.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125923899","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"GPECOM 2022 Cover Page","authors":"","doi":"10.1109/gpecom55404.2022.9815639","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815639","url":null,"abstract":"","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124740636","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Implementing renewable energy technologies in the city of Jeddah","authors":"Montaser Shaban Kabakibou, C. Chatwin","doi":"10.1109/gpecom55404.2022.9815796","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815796","url":null,"abstract":"This research investigates the possibility of implementing different renewable energy technologies in a city and integrating them into the electrical supply grid. A system model is created using Simulink to explore and manage the different technologies. Several energy storage systems are used to compensate for the fluctuations caused by the inconsistency of the different renewable sources.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"161 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124816728","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of a Vehicle-to-Grid (V2G) Energy Management System to Mitigate Local Operational Challenges in Low Voltage Distribution Networks with Photovoltaics","authors":"Furkan Gunes, M. A. Zehir","doi":"10.1109/gpecom55404.2022.9815823","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815823","url":null,"abstract":"Electric vehicles have been rapidly growing, especially in the last 10 years, with sales rates that have nearly doubled every two years. In combination with the evolving technology, parameters such as the driving range, charging power, and battery capacity of vehicles are increasing. It is of great importance that the integration of electric vehicles into existing networks, the possible difficulties they may cause, and the services that can be provided from the vehicle to the grid (Vehicle-to-Grid V2G) can be accurately predicted through detailed analysis. This study aims to prevent local network operational problems related to voltage, which may be encountered in low voltage distribution networks, including solar panels and electric vehicles, with improved power and energy management approaches based on V2G. In a 10-house LV distribution network based on real data, the daily charging behavior of electric vehicles as well as household consumption and solar generation profiles, the effectiveness of a V2G approach that considers the busses that are most effective in solving local voltage problems is investigated. The study provided useful findings for solving local problems, with realistic scenarios and comprehensive analyzes, with the developed vehicle-to-grid power and energy management approaches in low voltage distribution networks including distributed generation from solar energy and electric vehicles.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128490764","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yubin Duan, Yi Wei, Xiaohu Wang, Xinyuan Chen, Chaohui Zhao
{"title":"Controller Design and Stability Analysis of Electric Spring with Switchable Smart Load","authors":"Yubin Duan, Yi Wei, Xiaohu Wang, Xinyuan Chen, Chaohui Zhao","doi":"10.1109/gpecom55404.2022.9815751","DOIUrl":"https://doi.org/10.1109/gpecom55404.2022.9815751","url":null,"abstract":"Aiming at the characteristics of the traditional electric spring (ES) to stabilize the voltage of critical load (CL), electric spring with switchable smart load (SSL) is studied. The basic principle of ES with SSL is discussed, a control strategy is proposed to use one PR controller to control different loads respectively by using the indirect voltage control method. The controller parameters are deduced by the method of root locus, the stability of the controller is analyzed by using the method of state space modeling, and Matlab is used to compare and analyze the stability of the system when stabilizing different load voltages when the R/X ratio of line impedance is different. The results show that the switching of smart load (SL) and the voltage stabilization of different loads can be realized under the designed controller parameters.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129529214","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}