Yasumasa Hitomi, Nodoka Sato, M. Hayashi, Naohisa Eto, Y. Kinugawa, Takayuki Nishigaki, Y. Mizuno-Matsumoto
{"title":"Prevention of hemodialysis-induced hypotension by increasing the venous return","authors":"Yasumasa Hitomi, Nodoka Sato, M. Hayashi, Naohisa Eto, Y. Kinugawa, Takayuki Nishigaki, Y. Mizuno-Matsumoto","doi":"10.4009/JSDT.44.1085","DOIUrl":"https://doi.org/10.4009/JSDT.44.1085","url":null,"abstract":"Patients requiring hemodialysis have a variety of dialysis-associated complications. In particular, hypotension is a potential complication of chronic hemodialysis patients, which unexpectedly occurs during treatment and interrupts the continuation of dialysis, creating feeling of distress for the patients. Recently, the Crit-Line monitor has been clinically used and the signs of dialysis hypotension can be recognized by monitoring the blood volume changes (ΔBV) before the actual onset of the disease. However, the Crit-Line monitor is not omnipotent and can only help to prevent the development of dialysis hypotension secondarily and in a predictive way. In light of stabilizing blood pressure during dialysis and preventing dialysis-associated hypotension, we have focused on the venous return as a factor leading to stabilization of the blood volume changes ΔBV, and investigated the possibility that accelerated venous return results in maintaining blood pressure during hemodialysis. The subjects of this study are 8 hemodialysis patients on maintenance.We used a sequential pneumatic compression massage tool (foot pump) to accelerate the venous return during hemodialysis. First, the venous return was accelerated by a continuous massage with foot pumps during hemodialysis. Conditions of the massage were classified into 3 categories: Condition ① was no massage (control), Condition ② was a slight massage, and Condition ③ was a hard massage. Values of ΔBV were observed under these conditions for two weeks. As a result, more significant stabilization of ΔBV in the latter half of hemodialysis session was found in the groups with massage. Sensory changes were also studied and compared: Pre-dialysis, post-dialysis, and after returning home. In Condition ② a significantly better result of sensory changes was obtained after dialysis than before dialysis. Furthermore, it was confirmed that massage prevents peripheral circulation by measuring the transcutaneous partial pressure of oxygen (tcPO2), which was monitored continuously during hemodialysis. Consequently, any changes showing significant differences were not found during dialysis. In this study, a possible prevention of dialysis hypotension by accelerating the venous return is discussed.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"127 7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124239852","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of a solar-powered underwater glider","authors":"M. Arima, Tomoki Yamada","doi":"10.1109/UT.2011.5774120","DOIUrl":"https://doi.org/10.1109/UT.2011.5774120","url":null,"abstract":"Several kinds of autonomous underwater vehicles (AUVs) are now in operation for scientific investigation and industrial survey. One of the most important issues of AUV operation is power supply. An alkaline or lithium-ion battery is usually equipped in AUVs, but operational duration is restricted to several hours owing to limitations in space for battery storage. However, underwater gliders driven by a buoyancy engine have a high degree of energy efficiency. The purpose of this research is to study the feasibility of an underwater glider powered by a solar battery so as to realize enhancement of the endurance. The experimental glider, SORA, is equipped with solar panels on the main wings and the upper side of the fuselage, and two thrusters on both sides of the frontal body. Tank tests were conducted to validate the solar-powered underwater gliding system.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"410 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115997822","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ryota Sakamoto, Yuki Yoshimura, T. Sugiura, Y. Nomura
{"title":"A motion instruction system using head tracking back perspective","authors":"Ryota Sakamoto, Yuki Yoshimura, T. Sugiura, Y. Nomura","doi":"10.1299/jsmemecjo.2010.7.0_141","DOIUrl":"https://doi.org/10.1299/jsmemecjo.2010.7.0_141","url":null,"abstract":"In the practice of sports, dances, etc., we learn postures or motions from visual information such as videos in many cases when we are not directly taught by an instructor. As their improvement, some systems in which a learner follows 3D CG target model have been proposed. However the method of 3D posture instruction is not established yet since the depth distance is not shown clearly and the viewpoint is not suitable. In this paper we proposed a posture instruction system that shows 3D human model CG on a HMD (Head Mounted Display) in the virtual space. Specifically, the system shows target model and current lecturer's model on the HMD, being superimposed and it also shows such guiding objects as arrows. Furthermore, we proposed “Head Tracking Back Perspective” that trainee's viewpoint follows head movement. The experimental results show that the system is effective to instruct static postures.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128933405","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Uchida, R. Nakao, C. Asai, T. Jin, Y. Shiine, H. Nishikawa
{"title":"Optical counting of trapped bacteria in dielectrophoretic device with pillar array","authors":"S. Uchida, R. Nakao, C. Asai, T. Jin, Y. Shiine, H. Nishikawa","doi":"10.1080/10798587.2008.10643234","DOIUrl":"https://doi.org/10.1080/10798587.2008.10643234","url":null,"abstract":"The development of rapid, accurate and simple screening system is essential in actual processes for large-volume water treatment from a standpoint of recent strict regulations. In the present work, we newly produced a dielectrophoretic device with three dimensional microstructures and sophisticated microchannel to trap and detect bacteria efficiently. We measured the luminous area and intensity of stained bacteria in the gap between electrodes, and estimated the number of trapped bacteria quantitatively. The dependence of the trapping efficiency of bacteria on flow velocity was also discussed.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"104 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123133786","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Ishizuka, Hiroaki Koga, Z. L. Grigorievich, T. Yamakawa
{"title":"Cell necrotization in rat brain by the cryogenetic probe","authors":"S. Ishizuka, Hiroaki Koga, Z. L. Grigorievich, T. Yamakawa","doi":"10.1080/1931308X.2008.10644192","DOIUrl":"https://doi.org/10.1080/1931308X.2008.10644192","url":null,"abstract":"The realization of minimally invasive epilepsy surgery treatment, our goal, needs not only the localization of epileptic focus exactly and also the excision of the focus accurately by minimally invasive way. We think one of the best ways is cryosurgery. Cryosurgery is used to excise cancer of liver and kidney tumor as minimally invasive surgery. However, cryosurgery is not applied to epilepsy and the effect of cryosurgery on brain tissue is not well known. In this paper, we investigated the effectivity of cryosurgery by application to rat brains. We performed cryosurgery to rat under the several conditions. After these surgeries, we stained these specimens with H&E and observed them about the broken aresize and changes in the tissue. These results shows cryosurgery can be applied to epilepsy.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"129 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121216421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Hagiwara, K. Yamada, Y. Ando, I. Murakami, Satoshi Aoyama, S. Matsuura
{"title":"A design method for modified PID control systems for multiple-input/multiple-output plants to attenuate unknown disturbances","authors":"T. Hagiwara, K. Yamada, Y. Ando, I. Murakami, Satoshi Aoyama, S. Matsuura","doi":"10.1080/1931308X.2008.10644189","DOIUrl":"https://doi.org/10.1080/1931308X.2008.10644189","url":null,"abstract":"The Proportional-Integral-Derivative (PID) controller structure is the most widely used one in industrial applications. However, PID controller cannot stabilize any plant. In order to overcome this problem, Yamada and Hagiwara proposed a design method for modified PID controllers such that the modified PID controller makes the control system for unstable plants stable and the admissible sets of P-parameter, I-parameter and D-parameter are independent from each other. When modified PID control systems are applied to real plants, the influence of disturbance in the plant must be considered. In many cases, the disturbance in the plant is unknown. It is comparatively easy to attenuate known disturbances, but it is difficult to attenuate unknown disturbances. From a practical viewpoint, it is desirable to design a modified PID control system to attenuate unknown disturbances. Recently, a design method for modified PID control systems for to attenuate unknown disturbances was proposed. However, no paper examines a design method for modified PID control systems for multiple-input/multiple-output plants to attenuate unknown disturbances. In this paper, we propose a design method for modified PID control systems for multiple-input/multiple-output plants to attenuate unknown disturbances.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122547241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Survey of cooperative algorithm in robocup middle size league","authors":"Yuichi Kitazumi, K. Ishii","doi":"10.1299/JSMERMD.2010._1P1-F25_1","DOIUrl":"https://doi.org/10.1299/JSMERMD.2010._1P1-F25_1","url":null,"abstract":"Rob°Cup is an international joint project to promote Artificial Intelligence (AI), robotics, and related fields since 1996. Rob°Cup project has been held every year, and the performance of robot shows great advance. Especially, Soccer Middle Size League (MSL) uses big robots and the biggest field in the Rob°Cup projects, and audience can enjoy powerful games. During the 13 years Rob°Cup project, a lot of teams have advanced various researches for solving problems of multi-agent system. Our survey presents an overview of the cooperative algorithms used in MSL. We summarize about various approaches of multi agent system of different teams, and discuss what will become possible in near future and which kind of approach will be effective. We hope this survey will become good information for many researchers in robotics, and expect a lot of new teams will participate to the Rob°Cup.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128305213","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Sakanushi, K. Yamada, S. Matsuura, T. Hagiwara, Y. Ando, I. Murakami
{"title":"A design method for two-degree-of-freedom simple repetitive control systems for multiple-input/multiple-output plants","authors":"T. Sakanushi, K. Yamada, S. Matsuura, T. Hagiwara, Y. Ando, I. Murakami","doi":"10.1080/1931308X.2008.10644187","DOIUrl":"https://doi.org/10.1080/1931308X.2008.10644187","url":null,"abstract":"The modified repetitive control system is a type of servomechanism for periodic reference inputs. That is, the modified repetitive control system follows the periodic reference input with a small steady state error, even if a periodic disturbance or uncertainty exists in the plant. Using previously proposed modified repetitive controllers, even if the plant does not include time-delay, transfer functions from the periodic reference input to the output and from the disturbance to the output have infinite numbers of poles. To specify the input-output and the disturbance attenuation characteristic easily, Yamada et al. proposed the concept of a simple repetitive control system such that the controller works as a modified repetitive controller and transfer functions from the periodic reference input to the output and from the disturbance to the output have finite numbers of poles. In addition, Yamada et al. clarified the parameterization of all stabilizing simple repetitive controllers. Recently, the parameterization of all stabilizing two-degree-of-freedom simple repetitive controllers those can specify the input-output characteristic and the disturbance attenuation characteristic separately was proposed. However, the parameterization of all stabilizing two-degree-of-freedom simple repetitive controllers for multiple-input/multiple-output plants has not ever been considered. The purpose of this paper is to clarify the parameterization of all stabilizing two-degree-of-freedom simple repetitive controllers for multiple-input/multiple-output plants.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128575277","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Control of cellular organization around collagen beads using dielectrophoresis","authors":"S. Miyata, Yuki Sugimoto","doi":"10.1080/10798587.2008.10643235","DOIUrl":"https://doi.org/10.1080/10798587.2008.10643235","url":null,"abstract":"Tissues formed by cells seeded in hydrogels are used for biotechnology, cell-based assays, and tissue engineering. We have previously presented a cell-micropatterning technique that localizes live cells within hydrogels using dielectrophoretic (DEP) forces, and have demonstrated the ability to modulate tissue function through the control of microscale cell architecture. In this study, we developed a novel cell patterning technology for accumulating cells around collagen micro-beads. As a case study, we produce collagen-alginate beads for scaffold and accumulate chondrocytes around the micro-beads by combining DEP force and flow of the buffer solution. This approach enables an expanded range of studies examining the influence of 3D cellular architecture on microscale levels.","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125155389","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Separation of leukemia cells from blood by employing dielectrophoresis","authors":"H. Imasato, T. Yamakawa, M. Eguchi","doi":"10.1080/10798587.2008.10643232","DOIUrl":"https://doi.org/10.1080/10798587.2008.10643232","url":null,"abstract":"Our goal is development of a new automatic blood cell counter that it can detect a small amount of leukemia cells in the blood of patients. We employ the dielectrophoresis (DEP). In this paper, we examine whether or not realization that a living blood cells are separated by employing the dielectrophoresis. Leukocyte and erythrocyte are separated by dielectrophoresis under 60MHz, 10Vpp. Furthermore, normal leukocytes and BALL-1 which is one kind of leukemia cells were separated under 37KHz,14Vpp","PeriodicalId":433462,"journal":{"name":"2010 World Automation Congress","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124936661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}