{"title":"A neural network interpolator for the improvement of power rectifiers control","authors":"B. Francois, J. Cambronne","doi":"10.1109/ISIE.1996.548448","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548448","url":null,"abstract":"The studied rectifier consists of an input AC second order filter, a four switch matrix and an output DC filter. The objectives of the rectifier are: regulation of the DC current; sinusoidal input current waveform; and optimal power factor. In order to satisfy these objectives, the authors have designed a control algorithm which includes an internal closed loop for the control of the AC current and an external loop respective to the control of the mean value DC current. Because of algorithm convergence problems at the start, a second control algorithm is temporarily used to obtain a nonnull DC current. The presented results show degradations of electrical quantities due to the transition between these two algorithms. To compensate these degradations, a neural network controller is designed to interpolate through the two control algorithms. Simulation results show better signal waves with a reduced implantation dimension.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116604504","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On-line particle size distribution analysis of pulverised coal","authors":"G. Hancke, R. Malan","doi":"10.1109/ISIE.1996.551093","DOIUrl":"https://doi.org/10.1109/ISIE.1996.551093","url":null,"abstract":"The particle size distribution of the pulverised coal in a fossil fuel power station is an important and useful parameter for the efficient control of power generation. However, to put this parameter to its most effective use, it is necessary to measure it online. An investigation conducted into techniques used for the online measurement of particle size revealed a cost effective technique to achieve this goal. It shortly entails the measurement of the resonant vibrations evoked in a structure when pneumatically conveyed particles collide with it. By analysing the frequency spectra of these evoked vibrations, variations in the size distribution of the particles colliding with the structure can be observed. Test results of preliminary tests done on a pilot plant confirm the usefulness of this technique.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"507 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120884416","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of three phase controlled rectifier with current active filter","authors":"W. Koezara, P. Biloskorski","doi":"10.1109/ISIE.1996.551015","DOIUrl":"https://doi.org/10.1109/ISIE.1996.551015","url":null,"abstract":"The subject of this paper is the analysis of three-phase rectifiers with active filters. The new concept of three-phase controlled rectifier input current filtering is proposed and analysed. A modified technique for input current and output voltage control are presented. The simple hysteresis-band current control PWM method ensures a nearly sinusoidal input current with low harmonic content. Applying an additional active filter in parallel to the main circuit of the rectifier, much better quality of input current is obtained. This additional filter is able to operate with much higher switching frequency and low power, and in this way high harmonic content is significantly reduced and shifted to much higher frequencies. A voltage control loop yields good output performance.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"12 12","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120922475","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An induction motor drive with stator flux oriented control low-cost implementation","authors":"V. Lovati, M. Oberti, M. Marchesoni, P. Segarich","doi":"10.1109/ISIE.1996.548413","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548413","url":null,"abstract":"A vector controlled induction motor drive has been developed by the authors, by using a low cost control architecture. In particular, the stator flux orientation concept has been followed, no speed sensors have been used and all the drive control functions (i.e. signals acquisition and conversion, state observation, flux and torque control, PWM modulation, etc.) have been implemented on a single-chip. A prototypal experimental realization has been developed, and very good results have been obtained. The theoretical approach that has been followed, the main design choices and the most significant experimental results which have been obtained, are presented.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127470409","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design of fuzzy logic speed controller for brushless DC motor drives","authors":"V. Donescu, D. Neacşu, G. Griva","doi":"10.1109/ISIE.1996.548455","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548455","url":null,"abstract":"This paper presents a fuzzy logic speed controller (FLSC) for variable speed drives using current-controlled brushless DC motors. The fuzzy logic (FL) approach applied to speed control leads to an improved dynamic behaviour of the motor drive system and an improved immunity to load perturbations and parameter variations. The FLSC is designed using a simple algorithm based on a supposed analogy between the control surfaces of the FLSC and a a given proportional-integral controller for the same application. Simulation results are presented to show the performance of the proposed FLSC.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127544053","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Two degree of freedom internal model control for single tubular heat exchanger system","authors":"N. Abe, K. Seki, H. Kanoh","doi":"10.1109/ISIE.1996.548429","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548429","url":null,"abstract":"A two degree freedom internal model control (IMC) is implemented for the temperature control of a single tubular heat exchanger system. The experimental heat exchanger system is a very simple structure, however, the characteristics are regarded as a distributed parameter system and time delay made by software; the plant is regarded as complex system. With the aim of applying IMC structure, we approximate the heat exchanger system to a time delay model from a frequency response examination. In the laboratory experiment, it is clear that: (1) the two degree of freedom IMC is effective for the time delay system; (2) the two degree of freedom performance of IMC was superior to one degree freedom IMC; the disturbance was reduced compared to a PI controller or one degree of freedom IMC design; (3) since the controller had two degrees of freedom, the one tuning filtering parameter of the IMC controller effected the tracking of the reference and the other tuning parameters of IMC reduce disturbance; (4) the design method was as simple as an ordinary one degree of freedom IMC design; and (5) since the IMC controller was constructed from the system model, there were some problems to set up the modeling and identification.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124801168","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Robust control of a crude unit","authors":"M. Tibaldi, M. Dall'osso","doi":"10.1109/ISIE.1996.548425","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548425","url":null,"abstract":"The product quality control is a main issue in a crude unit which performs the initial distillation of the crude oil into several boiling range fractions. The specifications vary according to the processing capabilities and the market demand. The crudes have greatly different physical characteristics. A quadratic dynamic matrix control (QDMC) has been used to design a controller which is able to guarantee different setpoints with the same crude, the same setpoint with different crudes and both of them. Four detailed models (with 5 input variables and 4 control objectives) of the same crude unit working with different crudes have been derived from literature. Some of the 20 input-output transfer functions of each model are nonminimum phase. Validation of the controller has been done by (i) assuming a \"design\" model for the design of the controller, (ii) using three different models for the \"true\" crude unit, (iii) requesting a significant variation of the setpoint (naphtha/kero, kero/LGO, etc., cutpoints). Some guidelines about the choice of the design parameters (prediction horizon, control horizon, input/output weights, input/output constraints, etc.) are given in order to achieve both stability robustness and performance robustness.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125032712","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Internal model control using neural networks","authors":"Isabelle Rivals, L. Personnaz","doi":"10.1109/ISIE.1996.548401","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548401","url":null,"abstract":"We propose a design procedure of neural internal model control systems for processes with delay. We assume that a stable discrete-time neural model of the process is available. We show that the design of a model reference controller for internal model control necessitates only the training of the inverse of the model deprived from its delay, provided this inverse exists and is stable. As the robustness properties intrinsic to internal model control systems are only obtained if the inverse model is exact, it is also shown how to limit the effects of a possible inaccuracy of the inverse model due to its training. Computer simulations illustrate the proposed design procedure.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126630651","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High power multiresonant converter for telecommunication equipments","authors":"F. Lafitte, B. Dakyo, L. Protin","doi":"10.1109/ISIE.1996.551035","DOIUrl":"https://doi.org/10.1109/ISIE.1996.551035","url":null,"abstract":"The paper deals with a high power LCCL DC-DC multiresonant converter power supply for telecommunication equipment. The multiresonant concept is here adopted for soft ZVS commutation benefits and switching frequency increase. The involved theoretical analysis and design of such power circuits are tied to the working mode multiplicity and the validity field of power converter behavior in the frequency domain. Multiresonance leads to an over second order system, so the system working conditions study becomes more difficult. The major specifications of the present study are total definition and control of full load and no-load conditions. These working conditions must be obtained without any change of the power converter switching principle (ZVS), for the whole predefined frequency range.","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126719960","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Kucer, I. Chrabaszez, J. Altus, P. Spánik, B. Dobrucký
{"title":"Comparison of several types of speed controllers with the kind based on fuzzy logic","authors":"P. Kucer, I. Chrabaszez, J. Altus, P. Spánik, B. Dobrucký","doi":"10.1109/ISIE.1996.548526","DOIUrl":"https://doi.org/10.1109/ISIE.1996.548526","url":null,"abstract":"The paper deals with comparison of PI sliding mode, state space and fuzzy controller for speed control of synchronous motor drive. A short description of controllers is given. The goals of the paper are to give a short review of those speed controllers and their comparison according to often discussed questions. Is a fuzzy controller better then other ones? When and why to use a fuzzy controller? Is it cheaper, or robust, or easy to design? Is it just a fashion trend, or is it really progress? The paper gives brief information about the design of fuzzy controllers. The simulation experiment and real time measurement results are shown respectively. The verification of controllers' design is done on a test rig with permanent magnets synchronous motor (PMSM) fed from a voltage source inverter (VSI).","PeriodicalId":433364,"journal":{"name":"Proceedings of IEEE International Symposium on Industrial Electronics","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122363198","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}