{"title":"Parametric study on the thermal gradient of a small stratified domestic oil storage tank","authors":"A. Mawire","doi":"10.1109/DUE.2016.7466701","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466701","url":null,"abstract":"A simplified one dimensional model for a small stratified domestic oil storage tank is used for a parametric study on the thermal gradient in the storage tank. The model is validated with experimental results and reasonably good agreement between experiment and simulation is obtained. The effects of measurable and physically adjustable parameters of the average charging flow-rate, the inlet charging temperature and the heat loss factor on the thermal gradient are investigated with the model.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121332940","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electrical energy consumption analysis for sanitary water heating in student residences","authors":"H. Vermeulen, S. Fast","doi":"10.1109/DUE.2016.7466710","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466710","url":null,"abstract":"Energy consumption for sanitary water heating represents an important component of the overall energy costs associated with student residences. This paper presents the results of an investigation to analyse the water heating energy consumption profiles of 21 student residences representing of the order of 4600 occupants over a period of three years. Half-hourly energy metering profiles for heat pump installations are analysed with the view to derive statistical indicators such as the average daily energy consumption per occupant, the average daily half-hourly consumption per occupant profile and the average consumption per occupant for the Time of Use (TOU) periods associated with the MegaFlex and HomeFlex tariff systems. The development of a custom software application for performing the required data processing operations is discussed. The results show an average daily energy consumption of 1.76 kWh per occupant, which translates into an average daily hot water usage of approximately 101 l per occupant. The peak periods of the average daily energy consumption profiles derived for the heat pump energy consumption profiles coincide with morning and evening peak periods of the Megaflex and Homeflex TOU tariffs.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114731998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimizing flat plate solar collector geometry for a solar water heating system","authors":"A. Elhabishi, J. Gryzagoridis","doi":"10.1109/DUE.2016.7466719","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466719","url":null,"abstract":"This paper presents results obtained when comparing the performance of a solar water heating system equipped with flat plate solar collector panels of numerically identical surface area but of different geometric configuration. Data was obtained inside a laboratory using a solar simulator consisting of an array of halogen lamps. The amount of heat acquired from collectors of solar energy depends primarily on the surface area that is exposed to the solar irradiance. However, the geometry of the collectors (such as vertically long, horizontally long, square or equal sides) was thought of affecting the amount of heat harvested. The experimental work tested specially manufactured flat plate solar collectors (provided by a local manufacturer). All three panels had identical collector's surface area but different geometrical orientation and were individually attached to a typical solar water heating system. The circulation of the water from the panel to the geyser was due to the self-induced thermo-syphon effect. The average solar radiation intensity was measurement on the collector's surface and, six thermocouples were inserted inside the tank at different levels to measure the water temperature on an hourly basis during the test period (7 hours per day for two consecutive days). The results obtained indicated that the system's thermal efficiency was best when the square collector was used. A dimensional analysis using the Π Buckingham method that was performed on the parameters affecting a flat plate solar collector yielded three dimensionless numbers that can lead to a power law relationship enhancing solar water heating systems' design.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115827407","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An experimental study to determine the performance and potential saving of swimming pool air source heat pump water heater","authors":"S. Tangwe, M. Simon, E. Meyer","doi":"10.1109/DUE.2016.7466724","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466724","url":null,"abstract":"Swimming pool desirable water set temperature can range from 27-30 °C depending on the season of the year. The energy consumption in a bid to heat up the water to the set point temperature can be daunting especially when utilizing convectional electric heaters. The implementation of a swimming pool, air source heat pump as an efficient and renewable energy device could lead to a significant reduction in the energy consumption. The paper focused on the determination of the dynamic power consumption of the swimming pool heat pump which is correlated to the coefficient of performance (COP) of an installed pool heat pump required to heat up a 75000 liters of stored water to set point temperature of 30 °C. A data acquisition system was designed to accommodate power meters, heat pump inlet and outlet water temperature sensors, flow meter and the ambient temperature sensor. All the sensors and power transducers were housed by a data logger configured to log every one minute. Base on the experimentally determine energy consumption of the swimming pool heat pump and the COP during various heating up cycles, the potential electrical energy saved could be achieved. The achievable demand and energy saving of the swimming pool heat pump water heater could facilitate the economic cost analysis with the goal of determining simple payback period.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"160 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131727962","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Energy use scenarios in an informal urban settlement in Johannesburg, South Africa","authors":"T. Makonese, D. Masekameni, H. Annegarn","doi":"10.1109/DUE.2016.7466703","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466703","url":null,"abstract":"This paper presents a survey from a sample of 52 households from three informal urban settlements in Tembisa, Johannesburg, namely Vusimuzi, Madela Kufa Section 1 and Madela Kufa Section 2. The survey covered energy needs for cooking, space heating, water heating and lighting. No information was requested on the age, gender, status in the household, income level of the respondents, or the number of persons in the household. Coal was the primary source of energy for cooking, water heating and space heating, while kerosene was frequently used for cooking and lighting, and less for water heating. The majority of informal dwellings were not connected to the electricity grid at the time of the survey, save for a few which were connected through petrol-powered electric generators or through electricity obtained from a network of illegal connections. None of the households purchased LP gas for domestic use; the fuel is generally perceived to be unsafe for use in these settlements. Factors such as seasonality, the availability and price of fuels, and socio-cultural aspects affect fuel choices and the quantity consumed.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130883233","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Environmental technology verification methods","authors":"S. Szewczuk","doi":"10.1109/DUE.2016.7466705","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466705","url":null,"abstract":"Environmental Technology Verification (ETV) is a tool that has been developed in the United States of America, Europe and many other countries around the world to help innovative environmental technologies reach the market. Claims about the performance of innovative environmental technologies can be verified by qualified third parties called \"Verification Bodies\". The \"Statement of Verification\" delivered at the end of the ETV process can be used as evidence that the claims made about the innovation are both credible and scientifically sound. With proof of performance credibly assured, innovations can expect an easier market access and/or a larger market share and the technological risk is reduced for technology purchasers. Such an ETV tool is yet to be developed and applied for the South African market. This paper will describe the current international developments on ETV and how it could find application in South Africa that is lagging behind the implementation of such a tool.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131682711","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Structural health monitoring concept to predict the remaining lifetime of the wind turbine structure","authors":"Marcel Schedat, T. Faber, Abiman Sivanesan","doi":"10.1109/DUE.2016.7466723","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466723","url":null,"abstract":"Wind turbines are typically designed for a lifetime of at least 20 years. After almost reaching their targeted lifetime they could be bought at a reasonable price and used by private owners for domestic use. As more turbines reach their design lifetimes the need for the evaluation and assessment on their continued operation is growing. Many older turbines are often not monitored, creating a lack of information on the loads history of a wind turbine. The application of condition monitoring systems for the observation of machines has been state of the art in many industries like the automobile industry, power plant technology, etc. Although components of wind turbines such as the gearbox, generator and main bearings have also been long since monitored, the use of Structural Health Monitoring for the observation on turbine structures however has taken a back seat. Hence, data regarding damage and positions susceptible to fatigue on turbine structures hardly exists. This complicates the effort in assessing the continued operation of a wind turbine. This project intends to determine the remaining useful life and to develop a structural monitoring concept that is economical not only to major stakeholders but also for private owners and small businesses as we transition into sustainable energy.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126326842","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A review on the performance assessment and optimization techniques of air source heat pump water heaters used in South Africa","authors":"J. Yongoua, S. Tangwe, M. Simon","doi":"10.1109/DUE.2016.7466725","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466725","url":null,"abstract":"Heat pump water heaters (HPWH) are classified as renewable energy efficient technologies and have had a high market penetration in South Africa since 2008. The market of this technology is fast gaining maturity and sales are expected to increase significantly in the upcoming years. This could be explained by their low energy consumption (about 67% lower than conventional geysers), relatively low operation cost, their environmental friendly nature and possibly the ease to retrofit with the old inefficient technologies. Therefore, we need to examine critically the performance of HPWH to ascertain its optimal operation in South Africa. This study deals with reviewing works carried out to assess and optimize the performance of Air Source HPWHs for efficient use in South Africa's weather conditions. It brings together the different models and simulations employed and developed for HPWH as well as the different findings and suggestions towards a better performance. The results show that, the COP of Air Source HPWH in South Africa is influenced by the combined effects of the ambient temperature and relative humidity, hot water usage profile, the size and shape of the evaporator as well as the condenser, type and configuration of compressor, the filling capacity of the refrigerant, standby losses and even the efficient installation of the system.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"104 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127994170","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimal scheduling of a grid-connected hydrokinetic-battery system under Time of Use tariff","authors":"K. Kusakana","doi":"10.1109/DUE.2016.7466712","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466712","url":null,"abstract":"In this work, the optimal power scheduling for a grid-connected hydrokinetic-battery hybrid system is proposed to sufficiently explore hydrokinetic energy and to benefit customers at demand side. The developed model for the hybrid system's optimal power flow management aims to minimize electricity cost subject to the power balance, hydrokinetic and battery storage outputs as well as other operational constraints. With respect to demand side management, an optimal control method is developed to schedule the power flow of hybrid system over 24-h. Simulation are performed using MATLAB, and the results demonstrate that operating the proposed hybrid system under the developed optimal energy management model can reduce the operation cost and allow consumers to generate substantial income by selling power to the grid.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129408831","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"How uninhabitable will rising carbon dioxide make the world?","authors":"P. Lloyd","doi":"10.1109/DUE.2016.7466699","DOIUrl":"https://doi.org/10.1109/DUE.2016.7466699","url":null,"abstract":"It is widely believed that the burning of fossil fuels has increased the CO2 content of the atmosphere (Step 1), which in turn has led to global warming (Step 2), which in turn has caused climate change (Step 3) which is characterized by an increase in the frequency and magnitude of extreme events, which in turn will render parts of the globe uninhabitable (Step 4). Each step in this line of argument is examined. The evidence for the first is good; that for the second very weak (it is difficult to say how much of the observed warming is natural). The third step has no factual basis, and it is demonstrated why it is difficult to determine the frequency of extreme events, let alone any changes in that frequency. Accordingly the fourth step in this line of argument must be regarded as fictional at best. It transpires that, during the time it has taken us to gain a proper understanding of \"climate change\", the cost of renewable energy has fallen to the point where many renewable technologies are now competitive with fossil power generation. Economics now drives renewables, making them all the more sustainable than they were.","PeriodicalId":430641,"journal":{"name":"2016 International Conference on the Domestic Use of Energy (DUE)","volume":"06 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127178279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}