{"title":"Distribution of Statistics of Chi-Square Goodness-of-Fit Tests for Small Samples","authors":"S. B. Lemeshko","doi":"10.1109/APEIE.2006.4292559","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292559","url":null,"abstract":"The problem of estimating parameters of stochastic dynamic nonlinear system by gradient method is considered. The gradient method is applied to the criterion of normalized one-step-ahead error minimum which is calculated by extended linearized Kalman filter. The gradient calculation algorithm for this target function is obtained. Performance of the method is shown on an example of three univariate linear dynamic systems mixture.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131367031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Plasma Chemical Etching of Silicon","authors":"B. Bogomolov","doi":"10.1109/APEIE.2006.4292430","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292430","url":null,"abstract":"The basic results of plasma etching of silicon in CCI<sub>2</sub>F<sub>2</sub>/O<sub>2</sub> in quartz reactor with teflon polymer by a covering are considered. The uninconsistent model of plasma chemical of etching (PCE) of silicon in plasma CCl<sub>2</sub>F<sub>2</sub>/O<sub>2</sub> in conditions of active delivery chemically active particles (CAP) is constructed at the expense of etching teflon polymer. The deep etching of silicon up to 180 mkm for 30 minutes is carried out. However anisotropy of deep etching of silicon low.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131288614","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Means of Prototyping of a Digital Control System of an Electromagnetic Drive","authors":"V. Kondratyev, A. Solovyev","doi":"10.1109/APEIE.2006.4292600","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292600","url":null,"abstract":"The problem of controller design for thermal heating in a multizoned thermal furnace is considered. A parabolic partial differential equation is used to describe the thermal heating process. Control objective is to provide desired thermal distribution and transient performances in presence of an unknown extemal distributed disturbance and time-varying parameter. The continuous-time distributed controller with the highest output derivative in feedback is used and one guarantees desired transients by inducing of two-time-scale motions in the closed-loop system.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"95 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"113998914","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Use of Additional Medical Systems at Carrying Out Physiotherapeutic Procedures in Autokinesitherapy with Estimation of the Treatment Dynamics and the Enhancement of its Efficiency","authors":"M. Klimenko, V. Pedder, D. V. Belik, O. Isakova","doi":"10.1109/APEIE.2006.4292383","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292383","url":null,"abstract":"Autokinesiterapy (CERTIFICATE {ACT}) - effective technology of treatment of the diseases, based{founded;established} including on optimization of current of liquid environments in a body of the person. It is necessary to note, that the wide spectrum of infectious and oncological diseases limits a scope the CERTIFICATE{ACT}. For a substantiation of use the CERTIFICATE{ACT} is used scrining diagnostics excluding oncology disease and which can be carried out by modern medical systems, including, thermovision by the equipment. In article the analysis of an opportunity of use in autokinesitherapy these medical systems is lead. Examples of pilot survey and treatment of patients are resulted.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115775284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modular 3-Port Isolated Current- and Voltage Measurement System for Advanced Converter Control","authors":"G. Kaserer, H. Weiss","doi":"10.1109/APEIE.2006.4292423","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292423","url":null,"abstract":"Precise isolated current and voltage measurement is a frequent task in measurement and control. 3- port isolation simplifies assembling of the measurement system. Typical applications are multichannel data acquisition, ground loop elimination, motor control and rapid prototyping. High common-m.de rejection ratios because of high rate of rise of voltages at switching (high switching speed of state-of-the-art semiconductors have rise and fall times typically less than 1 mus) could be reached by avoiding capacitive cross-coupling. The output signals are scaled signals (+/-10 V or 5 V range) suited directly for A/D-converters. This paper describes the concept of 3-port isolation in current- and voltage a measurement system which is a prerequisite for advanced converter control.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114588883","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of Kinetic Phenomenon in Polysilicon (Part 1)","authors":"A. Moiseev","doi":"10.1109/APEIE.2006.4292439","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292439","url":null,"abstract":"","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115420973","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"MW Sensors for Measuring Dielectric Spectra of Materials in Wide Frequency Band","authors":"B. Belyaev, N. A. Drokin, V. F. Shabanov","doi":"10.1109/APEIE.2006.4292434","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292434","url":null,"abstract":"The design of the non-uniform microstrip resonator for measuring permittivity and relaxation time of liquid crystals (LC) by two-frequency method is developed. It is shown, that jumps of wave resistance on length of the resonator allow to operating of own resonance frequencies in dispersion area of LC, that raises accuracy of measurements of the dielectric characteristics. The relaxation time of liquid crystal MBBA in nematic phase is determined.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114083352","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Statistical Significance of Measuring Small Inductance Values in 103 - 107 Hz Range","authors":"A. Mamonov","doi":"10.1109/APEIE.2006.4292505","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292505","url":null,"abstract":"","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114647285","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Adaptive Stabilization of the Inverse Pendulum","authors":"A. Kosolapov, O. Shpilevaya","doi":"10.1109/APEIE.2006.4292602","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292602","url":null,"abstract":"In the report the decision of the inverse pendulum stabilization with a mobile point with the help the speed vector method is considered, properties and specialties of system are discussed. In system the feedback on output variable derivatives is organized. It provides fast suppress action of uncontrollable disturbances and pendulum stabilization and a mobile platform. Estimations of required derivatives are determined with the help of two quick-response linear systems of the first and second order. Numerical simulation results are given. Recommendations are received at the choice of system parameters for stabilization of a pendulum and a platform in the origin of coordinates.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114722559","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Hardware Approaches to Practice of \"in vivo\" Bioimpedance Measurement in Various Noise Environment Conditions, in Treatment-and-Prophylactic Institutions","authors":"D. V. Belik, K. D. Belik","doi":"10.1109/APEIE.2006.4292394","DOIUrl":"https://doi.org/10.1109/APEIE.2006.4292394","url":null,"abstract":"The electroimpedancemetry method is to determine the characteristics for the given type of a tissue, the values of polarization parameters, which are expressed through physical values of electroconductivity and the permittivity which determined in one's turn by structural (base) and gradient (functional) physiological conditions of a tissue. An measuring instrument in structure of medical hardware system or the device, is always associated with the presence of broadband noise determined as change of components of a total tissues impedance, and additional physiological changes in an organism (in the area of measurement), and influence is direct on cables and elements of the measuring system. The bioimpedance measurement circuits on the basis of the medical systems which is working in difficult and complex noise conditions is realized.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125582121","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}