2013 Conference on Control and Fault-Tolerant Systems (SysTol)最新文献

筛选
英文 中文
A fault tolerant superheat control strategy for supermarket refrigeration systems 超市制冷系统的容错过热控制策略
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693861
K. Vinther, R. Izadi-Zamanabadi, H. Rasmussen, J. Stoustrup
{"title":"A fault tolerant superheat control strategy for supermarket refrigeration systems","authors":"K. Vinther, R. Izadi-Zamanabadi, H. Rasmussen, J. Stoustrup","doi":"10.1109/SYSTOL.2013.6693861","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693861","url":null,"abstract":"In this paper, a fault tolerant control (FTC) strategy is proposed for evaporator superheat control in supermarket refrigeration systems. Conventional control uses a pressure and temperature sensor for this purpose, however, the pressure sensor can fail to function. A contingency control strategy, based on a maximum slope-seeking control method and only a single temperature sensor, is developed to drive the evaporator outlet temperature to a level that gives a suitable superheat of the refrigerant. The FTC strategy requires no a priori system knowledge or additional hardware and functions in a plug&play fashion. The strategy is outlined by means of procedural steps as well as a flow chart that also illustrates the process of automatic tuning of the maximum slope-seeking controller. Test results are furthermore presented for a display case in a full scale CO2 supermarket refrigeration system.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128473710","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Computation of transfer function matrices for 2×2 strongly coupled hyperbolic systems of balance laws 2×2平衡律强耦合双曲系统传递函数矩阵的计算
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693813
K. Bartecki
{"title":"Computation of transfer function matrices for 2×2 strongly coupled hyperbolic systems of balance laws","authors":"K. Bartecki","doi":"10.1109/SYSTOL.2013.6693813","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693813","url":null,"abstract":"A transfer function representation for a class of distributed parameter systems described by two hyperbolic partial differential equations defined on a one-dimensional spatial domain is considered. Compared to the previously presented results, the paper focuses on the transfer function representation for systems described by strongly coupled hyperbolic equations. Formulas for converting the transfer function matrix of the decoupled canonical system into the form describing the original, strongly coupled system are proposed for two different boundary input configurations. The considerations are illustrated with a practical example of an electrical transmission line.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116482304","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Innovative fault detection, isolation and recovery on-board spacecraft: Study and implementation using cognitive automation 创新的航天器故障检测、隔离和恢复:使用认知自动化的研究和实现
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693950
A. Wander, R. Förstner
{"title":"Innovative fault detection, isolation and recovery on-board spacecraft: Study and implementation using cognitive automation","authors":"A. Wander, R. Förstner","doi":"10.1109/SYSTOL.2013.6693950","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693950","url":null,"abstract":"Fault detection and diagnosis is a crucial aspect in spacecraft operations and on-board software with respect to safety, reliability and performance. The success of a space mission depends on the adequate and timely system reaction to unexpected environmental changes and fault or failure of components or subsystems. Within this paper, case studies of current spacecraft applications are categorized with respect to the level of autonomy that is reached. The potential of further concepts that were not yet studied in the context of spacecraft fault detection, isolation and recovery (FDIR), but in industrial and aerospace applications are examined. As a result, the cognitive automation approach, developed by the Institute of Flight Systems of the Bundeswehr University München, is identified as highly promising technology for enhancing spacecraft on-board autonomy: Context sensitive reactions in case of unexpected failure are enabled by knowledge about the current system and environmental state, system operational capabilities and the impact of faults and recovery actions on the system and system performance. A study that applies the cognitive automation concept to the power subsystem of an interplanetary spacecraft is proposed.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"432 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127606767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Robust control systems for modern power electronics: applications and challenges 现代电力电子的鲁棒控制系统:应用和挑战
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693817
S. Fekriasl
{"title":"Robust control systems for modern power electronics: applications and challenges","authors":"S. Fekriasl","doi":"10.1109/SYSTOL.2013.6693817","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693817","url":null,"abstract":"Summary form only given. Power electronics has had rapid development in the last decade which has resulted in wider real-life applications at present. Along with the above, power converters lay the foundations of our future life by providing us with alternative and long-term solutions for environmentally clean renewable energy resources. A variety of power converter topologies have been developed in the past, and many new topologies are realised every day. While these converters are required to operate under a wide range of system conditions, the majority of the existing control system designs are based on tuning control gains at nominal conditions. As such gains can be tuned for particular operational condition(s), any out-of-nominal operation may cause converter control system to collapse. Secondly, most of existing designs disregard coupling effects in the plant dynamics results of which could be unsatisfactory performance at the operational envelope. In addition, there are inherent perturbations in power converters that cannot be compensated by such tuned controllers. Parametric uncertainties due to electrical elements, transportation/computational delays (as complex-valued uncertainties), sufficiently large load variations, voltage source distortions, unmeasured external disturbances (like faults), and sensor noises are examples of dominant perturbations that could affect the operation of power converters. Advanced robust control system designs can aid development for power converters with improved output performance. Besides, they offer clear optimisation and design guidelines to reduce the cost and size of converters. The goal of this talk is to highlight the benefits and capabilities of robust multivariable feedback control systems design in challenging power electronics applications. Along with a brief review on the pragmatic robust control design, results of such advanced designs in a number of power electronics and power systems control applications will be illustrated in this plenary paper.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115917322","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Model-free control of a two-dimensional system based on uncertainty reconstruction and attenuation 基于不确定性重构和衰减的二维系统无模型控制
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693885
R. Madonski, P. Herman
{"title":"Model-free control of a two-dimensional system based on uncertainty reconstruction and attenuation","authors":"R. Madonski, P. Herman","doi":"10.1109/SYSTOL.2013.6693885","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693885","url":null,"abstract":"This paper analyses the robustness of the Model-Free Control (MFC) technique. The experimental tests are conducted on a 2DOF laboratory manipulator. The multi-dimensional, nonlinear, time-varying, cross-coupled, and mostly unknown dynamics of the considered system makes an effective control of such plant a highly demanding task. Obtained results are compared with the outcomes of a classical PID controller, widely used in industrial applications. The gathered experimental data makes the MFC a powerful fault-tolerant approach, that can eventually grow to a noticeable alternative to the controllers used in engineering practice nowadays.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"113 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124695553","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Fault-tolerant model predictive control with active fault isolation 主动故障隔离的容错模型预测控制
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693880
D. Raimondo, G. R. Marseglia, R. D. Braatz, Joseph K. Scott
{"title":"Fault-tolerant model predictive control with active fault isolation","authors":"D. Raimondo, G. R. Marseglia, R. D. Braatz, Joseph K. Scott","doi":"10.1109/SYSTOL.2013.6693880","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693880","url":null,"abstract":"A robust control method is presented for linear systems subject to input and state constraints, bounded disturbances and measurement noise, and discrete faults in sensors, actuators, and system dynamics. The approach uses set-based fault detection and isolation techniques to coordinate switching between controllers designed for each fault scenario. In contrast to previous approaches, the fault isolation method uses an active input designed to guarantee isolability subject to input and state constraints.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128343158","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 46
Sensor fault detection, localization and reconstruction applied at WWTP 传感器故障检测、定位与重构在污水处理厂中的应用
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693917
K. Bouzenad, M. Ramdani, A. Chaouch
{"title":"Sensor fault detection, localization and reconstruction applied at WWTP","authors":"K. Bouzenad, M. Ramdani, A. Chaouch","doi":"10.1109/SYSTOL.2013.6693917","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693917","url":null,"abstract":"Principal Components Analysis (PCA) has been intensively studied and is widely applied in industrial process monitoring. The main purpose of using PCA is the dimensionality reduction by extraction of the feature space that still contain the most information in the original data set. Despite its success in this field, the most important obstacle faced is the sensitivity to noise, also the fact that the majority of collected data from industrial processes are normally contaminated by noise makes it unreliable in some cases. To overcome these limitations, several strategies have been used. One of these has been interested to combine the robustness theory with PCA method, such theory sonsists in robustifying the existing algorithms against noise or outliers. Fuzzy Robust Principal Components Analysis (FRPCA) is one of the result for such combination that acheive better result compared with the classical method. In this work the RFPCA method is used and compared with the classical one to monitoring a biological nitrogen removal process. The obtained results demonstrate the performances superiority of this method compared with the conventional one.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128160066","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Adapting dynamic reliability from probabilistic safety analysis to fault-tolerant control? 将动态可靠性从概率安全分析应用到容错控制?
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693819
P. Labeau
{"title":"Adapting dynamic reliability from probabilistic safety analysis to fault-tolerant control?","authors":"P. Labeau","doi":"10.1109/SYSTOL.2013.6693819","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693819","url":null,"abstract":"Summary form only given. Dynamic reliability is a general modeling framework that allows to accounting for the hybrid (i.e. discrete-continuous) nature of reliability and safety problems. It actually originates from the fields of probabilistic safety analysis, a.o. for nuclear power plants, and from attempts at accounting for control devices in system reliability theory. The proposed talk aims to review the concepts and methodology of dynamic reliability and their potential applications to fault-tolerant control and other applications.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127136348","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Sensor fault detection and isolation in the quadrotor vehicle using nonlinear identity observer approach 基于非线性恒等观测器的四旋翼飞行器传感器故障检测与隔离
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693948
Younes Al Younes, H. Noura, A. Rabhi, A. El Hajjaji, Nedaa Al Hussien
{"title":"Sensor fault detection and isolation in the quadrotor vehicle using nonlinear identity observer approach","authors":"Younes Al Younes, H. Noura, A. Rabhi, A. El Hajjaji, Nedaa Al Hussien","doi":"10.1109/SYSTOL.2013.6693948","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693948","url":null,"abstract":"The Fault Detection and Isolation (FDI) of a quadrotor vehicle, which is described by a nonlinear model, are tackled in this paper. The nonlinear identity observer is utilized to detect the various types of sensors faults, and the Generalized Observer Scheme (GOS) is used to isolate the faulty sensor. The robustness of the observer and its scheme is investigated through several simulation results to build the Decision- Making Unit (DMU) for the residuals. Various simulation results have validated the FDI method and shown the system performance towards different fault scenarios.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"98 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122379400","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Optimal tuning for an abrupt change detection algorithm: Application to an underground gallery structure health monitoring 突变检测算法的优化调谐:在地下廊道结构健康监测中的应用
2013 Conference on Control and Fault-Tolerant Systems (SysTol) Pub Date : 2013-10-01 DOI: 10.1109/SYSTOL.2013.6693897
V. Sircoulomb, Nicolas Stoffels, G. Hermand, G. Hoblos
{"title":"Optimal tuning for an abrupt change detection algorithm: Application to an underground gallery structure health monitoring","authors":"V. Sircoulomb, Nicolas Stoffels, G. Hermand, G. Hoblos","doi":"10.1109/SYSTOL.2013.6693897","DOIUrl":"https://doi.org/10.1109/SYSTOL.2013.6693897","url":null,"abstract":"The aim of this paper is to detect faults such as cracks in an underground structure to ensure its health monitoring. The proposed approach is based on an ARMAX modeling of a deformation sensor (a vibrating wire gauge), to generate a residual. This residual is then used by a statistical test, the dynamic cumulative sum, to generate a detection function which is compared to a threshold for decision. The main contribution of this paper is the use of the receiver operating characteristic curve to optimally tune the parameters of the statistical test and to have the best fault detection/false alarm rate. The originality of this work is that the receiver operating characteristic curve is used for two aims: First, to optimally tune the sliding windows width of the statistical test and second, to precisely tune the decision threshold. The effectiveness of the proposed method is highlighted on the application of an underground gallery structure health monitoring.","PeriodicalId":425662,"journal":{"name":"2013 Conference on Control and Fault-Tolerant Systems (SysTol)","volume":"69 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128875929","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书