{"title":"A graphic form with emergent properties for monitoring renewable generation stations","authors":"A. Hilliard, Fiona F. Tran, G. Jamieson","doi":"10.1109/RWEEK.2016.7573326","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573326","url":null,"abstract":"Electric transmission grid reliability and resilience are challenged by increased use of intermittent renewable generation. This paper describes a straightforward, short-term approach to support grid operators monitoring fleets of renewable generators: designing displays using emergent visual features to communicate functional properties. An example wind generator graphic form and integrated meteorology display page are described. This graphic design distinguishes four practically significant functional operating modes of most wind turbines using a compact, familiar barchart format that can be implemented in almost any control system.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131344828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Moore, P. Armstrong, Todd McDonald, M. Yampolskiy
{"title":"Vulnerability analysis of desktop 3D printer software","authors":"S. Moore, P. Armstrong, Todd McDonald, M. Yampolskiy","doi":"10.1109/RWEEK.2016.7573305","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573305","url":null,"abstract":"3D printing is an emerging manufacturing technology that can produce objects with complex geometries. The aerospace, automotive, and healthcare industries increasingly use this technology to manufacture functional parts. Falling prices for desktop 3D printers are making this technology available to consumers. The widespread adoption of 3D printing technology means it will soon become the target of cyber-attacks. In this paper we analyze to what extent desktop 3D printers are vulnerable to such attacks. The software under scrutiny is open source 3D printer software that is broadly used with desktop 3D printers. Static analysis of the source code, dynamic analysis of the communication between 3D printer and computer, and architecture analysis reveal numerous vulnerabilities that can be exploited.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126812575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Metrics required for power system resilient operations and protection","authors":"K. Eshghi, B. Johnson, C. Rieger","doi":"10.1109/RWEEK.2016.7573333","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573333","url":null,"abstract":"Today's complex grid involves many interdependent systems. Various layers of hierarchical control and communication systems are coordinated, both spatially and temporally to achieve gird reliability. As new communication network based control system technologies are being deployed, the interconnected nature of these systems is becoming more complex. Deployment of smart grid concepts promises effective integration of renewable resources, especially if combined with energy storage. However, without a philosophical focus on resilience, a smart grid will potentially lead to higher magnitude and/or duration of disruptive events. The effectiveness of a resilient infrastructure depends upon its ability to anticipate, absorb, adapt to, and/or rapidly recover from a potentially catastrophic event. Future system operations can be enhanced with a resilient philosophy through architecting the complexity with state awareness metrics that recognize changing system conditions and provide for an agile and adaptive response. The starting point for metrics lies in first understanding the attributes of performance that will be qualified. In this paper, we will overview those attributes and describe how they will be characterized by designing a distributed agent that can be applied to the power grid.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"30 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132198897","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An H-infinity approach to stealth-resilient control design","authors":"S. D. Bopardikar, A. Speranzon, J. Hespanha","doi":"10.1109/RWEEK.2016.7573307","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573307","url":null,"abstract":"We revisit the problem of stealth attack - a coordinated attack through several possible entry points - on a closed loop linear time invariant dynamical system. We propose a notion of the impact of such an attack on the system and consider a novel metric related to the H-infinity norm of the inverse of the system dynamics (assuming it exists) as a measure of the security of the system. We show that the problem can be cast as a linear matrix inequality optimization with the system parameters (observer gain) as the variable. This formulation allows a user to re-design the system from the perspective of minimizing the impact of any stealth attack. Numerical results on simulated data illustrate the security and performance tradeoff using the proposed approach.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"54 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114121050","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Syed Noor-ul-Hassan Shirazi, Antonios Gouglidis, Kanza Noor Syeda, Steven Simpson, A. Mauthe, I. Stephanakis, D. Hutchison
{"title":"Evaluation of Anomaly Detection techniques for SCADA communication resilience","authors":"Syed Noor-ul-Hassan Shirazi, Antonios Gouglidis, Kanza Noor Syeda, Steven Simpson, A. Mauthe, I. Stephanakis, D. Hutchison","doi":"10.1109/RWEEK.2016.7573322","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573322","url":null,"abstract":"Attacks on critical infrastructures' Supervisory Control and Data Acquisition (SCADA) systems are beginning to increase. They are often initiated by highly skilled attackers, who are capable of deploying sophisticated attacks to exfiltrate data or even to cause physical damage. In this paper, we rehearse the rationale for protecting against cyber attacks and evaluate a set of Anomaly Detection (AD) techniques in detecting attacks by analysing traffic captured in a SCADA network. For this purpose, we have implemented a tool chain with a reference implementation of various state-of-the-art AD techniques to detect attacks, which manifest themselves as anomalies. Specifically, in order to evaluate the AD techniques, we apply our tool chain on a dataset created from a gas pipeline SCADA system in Mississippi State University's lab, which include artefacts of both normal operations and cyber attack scenarios. Our evaluation elaborate on several performance metrics of the examined AD techniques such as precision; recall; accuracy; F-score and G-score. The results indicate that detection rate may change significantly when considering various attack types and different detections modes (i.e., supervised and unsupervised), and also provide indications that there is a need for a robust, and preferably real-time AD technique to introduce resilience in critical infrastructures.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122135223","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Robustness of power grid topologies against centrality-based attacks","authors":"A. Bhave, M. Crow, Egemen K. Çetinkaya","doi":"10.1109/RWEEK.2016.7573317","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573317","url":null,"abstract":"The power grid infrastructure is of paramount importance to society. Hence many studies have been undertaken to understand the structural properties of power grids to make them resilient. We study the topological robustness of three power grids - IEEE 300 bus, Western US, and Poland - against centrality-based targeted attacks on nodes and links. Our results indicate that the impact of attacks varies depending on the graph centrality metric being considered.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115983958","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement sensitivity analysis of information embedded power systems using ABCD matrices","authors":"Tiffany L. Lakins, C. Nwankpa","doi":"10.1109/RWEEK.2016.7573314","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573314","url":null,"abstract":"The purpose of this study is to investigate the effects of measurement set selection, placement and distortion on calculation of unmeasured buses in over-determined systems. Among questions posed is whether or not spatial distortion effects are more pronounced than their temporal counterparts. In addition, a proposed technique to derive multi-dimensional ABCD matrices is provided and their condition numbers are studied for the purposes of understanding effects, if any, on calculated unmeasured bus values. Example test cases included 3 and 9 bus power system models and inferences were obtained on effects of scaling results for larger sized power systems.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132383696","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Penkey, Matchyaraju Alla, B. Johnson, T. McJunkin
{"title":"Improving transmission system resilience using an automation controller and Distributed Resources","authors":"P. Penkey, Matchyaraju Alla, B. Johnson, T. McJunkin","doi":"10.1109/RWEEK.2016.7573313","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573313","url":null,"abstract":"As the transmission network has evolved over time, it has been operated closer to its limits and as a result lacks the ability to handle severe contingencies such as extreme weather, natural disasters, major generation failure, loss of transmission lines, or cyber-attacks. Depending on the timing of the event, these conditions could lead to cascading problems which can bring down an area larger than that directly affected by the event if they are not handled properly. Recent technological advancements in lower cost communication and control plus the increased use of distributed generation, gives an opportunity to break the transmission network into independent networks supplying local critical loads beyond the break points used by regional transmission operators. This paper demonstrates the concept with a relatively simple transmission system model and utilizes a commercial automation controller to partition the system. The local generators are able to supply the local critical loads. An algorithm is proposed to detect the abnormal situations and to isolate the system into independent networks. The isolated systems can supply the local critical loads under stable operating conditions following generator shedding or shedding of less critical loads. The entire system is modeled in a Real Time Digital Simulator (RTDS) along with an automation controller which communicates with model using the IEC 61850 standard protocol. The entire operation can be monitored and controlled with the help of a Human Machine Interface developed for the project.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132572977","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"System-Task Analytical Framework for Monitor Assessment","authors":"Nathan Lau, D. Powers","doi":"10.1109/RWEEK.2016.7573330","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573330","url":null,"abstract":"User interfaces of modern control rooms in process plants are mostly designed around computer monitors paired with mice and keyboards; thus, the number of monitors can have practical significance in shaping operator behaviors and performance, at least in terms access to displays and controls. For this reason, the number of monitors available to the operators is an important consideration in workstation design. This paper presents the System-Task Analytical Framework for Monitor Assessment (STAFMA) - a systematic, analytical method for determining the number of monitors required for operating a process. Adapting Cognitive Work Analysis, STAFMA consists of six phases of analysis - work domain, control tasks, strategies/plant procedures, control room crews, operators, and monitor allocation. The goal of this adaptation is to provide a systematic and analytical basis for guiding practitioners on the number of monitors for operating a process. The six phases of analysis also illustrate the interaction between various design choices and the required number of monitors.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"18 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134258424","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fault diagnosis based on partitioned power system models","authors":"M. Salman, Morteza Sarailoo, N. Wu","doi":"10.1109/RWEEK.2016.7573312","DOIUrl":"https://doi.org/10.1109/RWEEK.2016.7573312","url":null,"abstract":"Through partition of the model of a full power transmission network, this paper resolves the complexity issue arising from using a multiple model filtering (MMF) approach to transmission short-circuit fault diagnosis. The MMF approach to power system diagnosis was recently developed to mitigate cascading failures in power systems, caused by protection misoperations, through providing decision support for protective control actions. The partition is defined by the structure of a sensor network overlaid on the transmission network to support, among many functions, fault diagnosis. The ability to diagnose faults using the MMF approach relies on the observability of independent current and voltage variables of the transmission network from time-synchronized measurement samples acquired by the sensor network. The paper shows that such observability is retained in all partitioned networks, for which the complexity of real-time computation and communication is bounded despite the size of the full network. A set of rules for partitioning is stated in graph theoretic terms. The MMF approach to diagnosis of transmission line faults is applied to the IEEE 68-bus test system and the benefit in complexity reduction through partition is quantified.","PeriodicalId":425533,"journal":{"name":"2016 Resilience Week (RWS)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133965732","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}