2021 3rd Global Power, Energy and Communication Conference (GPECOM)最新文献

筛选
英文 中文
Experimental Comparison of GaN-Fet Based Motor Drives for High Switching Frequencies 基于GaN-Fet的高开关频率电机驱动的实验比较
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587536
Cenk Kiliç, G. Küçükyildiz, E. Meşe
{"title":"Experimental Comparison of GaN-Fet Based Motor Drives for High Switching Frequencies","authors":"Cenk Kiliç, G. Küçükyildiz, E. Meşe","doi":"10.1109/GPECOM52585.2021.9587536","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587536","url":null,"abstract":"As a new semiconductor switch, GaN-Fet provides a high switching frequency so that total harmonic distortion (THD) can be reduced in addition to rotor loss and noise level in motor drive applications. In this study, a GaN-FET based three phases inverter design is analyzed for an induction motor. The space vector PWM (SVPWM) method is used for two high switching frequencies, 50 kHz and 100 kHz. To implement this high-frequency application, a real-time system is designed with TI-BoostXL three phases GaN-Inverter and a low-cost microprocessor, STM32F407-VG is used. The system is modeled in MATLAB/Simulink environment. The embedded control algorithm is designed with STM32-Cube and Keil-MDK software with Hardware Abstraction Layer (HAL) and digital signal processing (DSP) libraries with floating-point unit (FPU).","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116910921","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Battery Energy Storage System for PMSG based Small Scale Wind Energy Conversion System 基于PMSG的小型风能转换系统的电池储能系统
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587752
Ayşe Nur Köklü, A. Polat, L. T. Ergene
{"title":"Battery Energy Storage System for PMSG based Small Scale Wind Energy Conversion System","authors":"Ayşe Nur Köklü, A. Polat, L. T. Ergene","doi":"10.1109/GPECOM52585.2021.9587752","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587752","url":null,"abstract":"The investments made to meet the rising energy demand have also increased in recent years. Renewable energy systems constitute a significant part of these investments. Due to the instability of renewable energy sources, battery energy storage systems (BESS) have started to be established alongside these systems. In this way, energy can be stored when the source is high, and when it is low, the necessary energy can be drawn from the battery. At this point, efficiency has become an important issue. In this study, wind energy conversion systems (WECS) working with permanent magnet synchronous generators (PMSG) are supported by BESS, and the energy produced here is given to the microgrid. The study is carried out on the more efficient operation of BESS. With the perturb & observe (P&O) method, which is one of the maximum power point tracking methods (MPPT), more efficient operation of the battery is ensured. The model is created in MATLAB&Simulink for different scenarios. The model is operated for different power states demanded by the microgrid and for different scenarios. The results are examined comparatively, and the observed improvements are shown when the P&O method is used.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"69 9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126014672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High Voltage Power Line Carrier. Obsolete Technology or Inherent part of the Power Transmission Electrical Grid? 高压电力线载波。过时的技术还是输电网固有的一部分?
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587493
A. Merkulov
{"title":"High Voltage Power Line Carrier. Obsolete Technology or Inherent part of the Power Transmission Electrical Grid?","authors":"A. Merkulov","doi":"10.1109/GPECOM52585.2021.9587493","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587493","url":null,"abstract":"The purpose of this paper is to present a strategic view on the future of the oldest type of communications in power transmission electrical grids – high voltage power line carrier (PLC) along transmission electrical power lines 35…500 kV. It provides analysis of development stages and nowadays conditions of the high voltage PLC. It discusses prospective areas for development of PLC systems and channels for voice and longtime electrical lines condition monitoring based on discrete multi-tone modems. It suggests variants of high voltage PLC channels application considering future specifics of creating telecommunications networks for transmission companies.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126034789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Magnetic Resonance Coupled Wireless Power Transfer Analysis For Electric Vehicle 电动汽车的磁共振耦合无线功率传输分析
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587543
Minhazur Rahman, Fariha Rahman, A.H.M Rasheduzzaman, Md. Fahim Shahriyar, M. Tanseer Ali
{"title":"Magnetic Resonance Coupled Wireless Power Transfer Analysis For Electric Vehicle","authors":"Minhazur Rahman, Fariha Rahman, A.H.M Rasheduzzaman, Md. Fahim Shahriyar, M. Tanseer Ali","doi":"10.1109/GPECOM52585.2021.9587543","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587543","url":null,"abstract":"Wireless power transfer (WPT) technique for charging Electric Vehicles (EV) shows a promising impact on the EV industry. However, there is a lack of a 230V AC input wireless charger for EV. This research aims to investigate a 230V AC input wireless power transfer for electric vehicle application according to the Society of Automotive Engineers (SAE) standard. Using Finite Element Analysis (FEA), the study analyzed the parameters of transmitter and receiver coil of a magnetic resonance coupled (MRC) WPT system and measured power and efficiency using the parameters of the coils. In addition, the co-simulation environment between Ansys Maxwell and Ansys Simplorer was used to validate the results. The study shows an AC output power of the coil between 240W to 3.58kW at different distances with the highest coupling coefficient of 0.32. Besides, the analysis indicates that the system can operate at different frequencies with maximum power transfer. Further studies are needed to establish less flux linkage between the coils to achieve a higher output power for the system and calculate the power losses.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123410631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Model-Free Simplified Predictive Current Control of PMSM Drive with Ultra-Local Model-Based EKF 基于超局部模型EKF的永磁同步电机无模型简化预测电流控制
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587527
E. Zerdali, P. Wheeler
{"title":"Model-Free Simplified Predictive Current Control of PMSM Drive with Ultra-Local Model-Based EKF","authors":"E. Zerdali, P. Wheeler","doi":"10.1109/GPECOM52585.2021.9587527","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587527","url":null,"abstract":"The importance of permanent magnet synchronous machines (PMSMs) is increasing day by day due to trends in the electrification of transportation and the use of wind farms. The predictive current control (PCC) strategy has been widely applied to the control of power converters and electrical machines over the past decade. However, parameter dependency and computational complexity are known disadvantages of the conventional PCC strategy. To deal with the weakness caused by parameter inconsistencies, model-free PCC strategy has been proposed. The simplified PCC strategies have also been applied to reduce computational complexity. In this paper, a model-free simplified PCC (MF-SPCC) strategy combined with the ultra-local model-based extended Kalman filter (EKF) has been proposed for a PMSM drive. The proposed electric drive system has been verified by simulation studies and finally robust control performance has been achieved under parameter mismatches.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116054335","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Digital Average Current Mode Controller Design for a DCM Output Inductor-less Phase-Shifted Full-Bridge DC/DC Converter 无DCM输出电感移相全桥DC/DC变换器的数字平均电流模式控制器设计
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587487
Muhammed Yusuf Candan, Halil I. Kavak, E. Durna
{"title":"Digital Average Current Mode Controller Design for a DCM Output Inductor-less Phase-Shifted Full-Bridge DC/DC Converter","authors":"Muhammed Yusuf Candan, Halil I. Kavak, E. Durna","doi":"10.1109/GPECOM52585.2021.9587487","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587487","url":null,"abstract":"In this study, we present a simulation based average modeling approach and a digital current mode controller design for an Output Inductor-less Phase-Shifted Full-Bridge (OIPSFB) DC/DC converter nominally operating in Discontinuous Conduction Mode (DCM). Average current mode control is utilized in the vast majority of Full-Bridge converter applications. One can apply state space averaging method to derive the Continuous Conduction Mode (CCM) system model of these converters because in CCM the system has dynamics closer to linearity. However, for DCM operation, the state space averaging method cannot be used directly because of the nonlinear characteristics due to discontinuous inductor current. In most of the derived average models for DCM, the start-up transition voltage waveform does not reflect the reality. In the model we present in this paper, we set a current limit to average inductor current state with clamping anti-windup. In this way, we obtained a more realistic start-up dynamic for the voltage. Also, to prevent the controller coefficients’ scaling problems in Digital Signal Controller (DSC), we include the real measurement systems’ dynamics in our model and obtained the controller parameters as digital values substituted in DSC. Throughout this paper, we detailed the proposed modeling and digital average current mode controller design approach. We demonstrated the accuracy of our model by comparing simulation results with real system results. Finally, we verified our designed controller on an experimental system.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129628643","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Towards Secure Traffic Signaling in Smart Grids 智能电网中安全的交通信号
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587535
V. O. Nyangaresi, Saeed Hamood Alsamhi
{"title":"Towards Secure Traffic Signaling in Smart Grids","authors":"V. O. Nyangaresi, Saeed Hamood Alsamhi","doi":"10.1109/GPECOM52585.2021.9587535","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587535","url":null,"abstract":"The transmission of consumer energy consumption reports from smart meters to the power management centers over insecure public communication channels exposes this data to numerous privacy and security attacks. This has seen the development of many authentications and key agreement (AKA) protocols to offer protection to the transmitted data. However, majority of these schemes still face many security, privacy and performance issues. Specifically, anonymity and untraceability features are missing in the majority of the current AKA protocols. In this paper, a privacy-preserving traffic signaling protocol is developed. Its security analysis shows that it is robust against impersonation, Man-in-the-Middle (MitM), de-synchronization and replay attacks. In addition, it provides untraceability, anonymity and perfect forward key secrecy. Moreover, it has average computation and storage costs, and the lowest communication costs among other related protocols.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126348913","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
UV discharge lamp electronic ballast based on ISOS resonant converter with integrated transformer 基于ISOS谐振变换器集成变压器的紫外放电灯电子镇流器
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587509
K. Kroičs
{"title":"UV discharge lamp electronic ballast based on ISOS resonant converter with integrated transformer","authors":"K. Kroičs","doi":"10.1109/GPECOM52585.2021.9587509","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587509","url":null,"abstract":"The paper describes design of input-series-output-series (ISOS) resonant converter based electronic ballast for ultra-violet gas discharge lamp powering. Proposed topology and control method allows achieve soft- switching of MOSFET transistors. Application of ISOS topology allows application of low voltage MOSFET transistors which are cheaper and with a better parameters. Integration of the transformer allows reduction of the price of magnetics components. The operation of the converter is described in the paper. Experimental prototype powered from three phase 400 V AC network with 3 kW output power has been built and experimental results confirms proper operation of the converter.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"124 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133633112","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Motor Starting Direct-on-line: Performance Analysis in ATP and MATLAB/SIMULINK Environments 电机在线起动:ATP和MATLAB/SIMULINK环境下的性能分析
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587781
Pedro H. Camargos, Fausto E. N. Campos, B. Fuly
{"title":"Motor Starting Direct-on-line: Performance Analysis in ATP and MATLAB/SIMULINK Environments","authors":"Pedro H. Camargos, Fausto E. N. Campos, B. Fuly","doi":"10.1109/GPECOM52585.2021.9587781","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587781","url":null,"abstract":"This paper presents a performance analysis of motor starting direct-on-line simulations in Alternative Transient Program (ATP) and MATLAB/SIMULINK. A comparative study between these two softwares was carried out with the objective of evaluating the advantages and disadvantages of both softwares in motor starting direct-on-line simulations. Operation conditions of no-load and nominal were analyzed and its results compared to catalog data for validation purposes.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"4 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115604420","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A PMU-based state estimator for networks including classic HVDC links 基于pmu的典型高压直流线路网络状态估计器
2021 3rd Global Power, Energy and Communication Conference (GPECOM) Pub Date : 2021-10-05 DOI: 10.1109/GPECOM52585.2021.9587607
G. Korres, Orestis Darmis, G. Karvelis
{"title":"A PMU-based state estimator for networks including classic HVDC links","authors":"G. Korres, Orestis Darmis, G. Karvelis","doi":"10.1109/GPECOM52585.2021.9587607","DOIUrl":"https://doi.org/10.1109/GPECOM52585.2021.9587607","url":null,"abstract":"This paper presents an equality-constrained weighted least squares (WLS) state estimation (SE) model for power systems including classic high voltage direct current (HVDC) links. Synchronized bus voltage and branch current phasor measurements, provided by phasor measurement units (PMUs), are used for the AC network. DC link voltage and current measurements are assumed to be sampled synchronously, time-stamped and reported at the same rate as PMU measurements. Linear AC and DC measurement equations are formulated, by applying the voltage and current phasors in rectangular coordinates. Zero injections and AC/DC coupling equations are treated as linear and nonlinear equality constraints, respectively. To validate the algorithm, a simulation study for a 4- bus hybrid AC/DC test system with one DC link is provided.","PeriodicalId":425303,"journal":{"name":"2021 3rd Global Power, Energy and Communication Conference (GPECOM)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123641042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书