2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)最新文献

筛选
英文 中文
Insulation design of 25.8kV class gas insulated switchgear in Dry Air 25.8kV级气体绝缘开关柜干空气绝缘设计
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757091
Hakju Lee, Jeuk Yeun, Hee-sup Ahn, Jong-Ki Choi, Yonggun Kim
{"title":"Insulation design of 25.8kV class gas insulated switchgear in Dry Air","authors":"Hakju Lee, Jeuk Yeun, Hee-sup Ahn, Jong-Ki Choi, Yonggun Kim","doi":"10.1109/ICEPE-ST51904.2022.9757091","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757091","url":null,"abstract":"Research on Eco-friendly gas used in gas insulated switchgear (GIS) has been studied in earnest since the Paris Climate Change Accord in 2015. Existing SF6 gas has excellent dielectric strength, but has a high global warming potential (GWP). On the other hand, dry air is easy to use in low voltage GIS because it has a lower global warming potential and low dielectric strength than SF6 gas.In this paper, the results of insulation test and electric field analysis of 25.8kV class gas insulated switchgear in Dry Air. The test was conducted with the test method of IEC 62271-1 \"Dielectric tests\". As a result of lightning impulse tests, insulation breakdown occurred in various shapes. Ansys Maxwell 3D electric field analysis was performed based on the test results.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122296018","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Plan for developing Modular Green Substation 模块化绿色变电站发展规划
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9756982
Inyoung Jun, Seungryle Oh, Hynuseok Kim, Kisun Han
{"title":"Plan for developing Modular Green Substation","authors":"Inyoung Jun, Seungryle Oh, Hynuseok Kim, Kisun Han","doi":"10.1109/ICEPE-ST51904.2022.9756982","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9756982","url":null,"abstract":"Modular Green Substation means combination of Modular Substation and Green Substation. Modular substation is a substation in which all of its facilities will be manufactured in modular type, stored in a container, and transported to a trailer. Green substation is a substation equipped with compensation facilities such as ESS, and FACTS to link renewable energy to power system by guaranteeing power quality. This paper deals with plans for development and application of Modular Green Substation to cope with emergencies in the case of substation failure and to improve the acceptability of renewable energy.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"195 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125724834","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Influence of the Dispersion in Pre-arcing Time of Vacuum Circuit Breakers on the Controlled Switching of Capacitor Banks 真空断路器预弧时间色散对电容器组控制开关的影响
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757113
Jincai Huang, Yun Geng, Qingbin Jin, Xinggui Chen, Jielu Yan, Yinsan Geng
{"title":"The Influence of the Dispersion in Pre-arcing Time of Vacuum Circuit Breakers on the Controlled Switching of Capacitor Banks","authors":"Jincai Huang, Yun Geng, Qingbin Jin, Xinggui Chen, Jielu Yan, Yinsan Geng","doi":"10.1109/ICEPE-ST51904.2022.9757113","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757113","url":null,"abstract":"The phase selection control vacuum circuit breaker (VCB) is an effective measure to suppress the inrush current when closing the capacitor bank. The accuracy of phase selection is affected by the pre-arcing time of the VCB and dispersion. This paper mainly uses the methods of experiment and simulation to study the influence of the pre-arcing time and dispersion of VCBs with cup-type axial magnetic field (AMF) contacts and spiral-type transverse magnetic field (TMF) contacts on phase selection to suppress inrush current. Firstly, the pre-arcing time of the VCB with two different contacts is measured through experiments and dispersion is calculated. Secondly, a simulation circuit based on the actual 40.5kV VCB switching capacitor bank experimental circuit parameters is established to calculate the inrush current amplitude in the two different phase control modes. Finally, the inrush current amplitude based on different phase selection methods are compared. The comparison results show that compared with the phase selection method based on the contact touched time of the vacuum interrupter, the phase selection method based on the pre-arcing time t50 is more conducive to suppressing inrush current. Compared with the cup-type AMF contacts VCB, the spiral-type TMF contacts VCB has a smaller pre-arcing time and dispersion.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132329971","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study on insulation property of bushing in Dry air 干燥空气中套管绝缘性能的研究
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757075
O. Jin-Seok, Park Hee-Tae, Park Chan-Sol, Kim Young-il
{"title":"Study on insulation property of bushing in Dry air","authors":"O. Jin-Seok, Park Hee-Tae, Park Chan-Sol, Kim Young-il","doi":"10.1109/ICEPE-ST51904.2022.9757075","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757075","url":null,"abstract":"The SF6 gas which widely used as insulation media due to its excellent insulation property, is being reduced application and also replaced by non-greenhouse gas ever since it has been designated as a greenhouse gas. For that reason, Dry air is being applied as an alternative gas to SF6 gas. Thus, in this study, through simulation and test, the application reference for the main bushing used for dry-air insulated high voltage switchgear has studied.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130210465","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Research on the evaluation method of eco-friendly gas in the application of high voltage circuit breaker 高压断路器中环保气体评价方法的研究
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757096
Haonan Sun, H. Long, Yi Wu, Jiefu Chen, C. Niu, M. Rong
{"title":"Research on the evaluation method of eco-friendly gas in the application of high voltage circuit breaker","authors":"Haonan Sun, H. Long, Yi Wu, Jiefu Chen, C. Niu, M. Rong","doi":"10.1109/ICEPE-ST51904.2022.9757096","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757096","url":null,"abstract":"In this paper, a comprehensive evaluation method on the insulation performance and greenhouse effect of environmentally-friendly gas was studied. Firstly, considering that the gas greenhouse effect is determined by its atmospheric lifetime and infrared characteristics, and can be assessed by the global warming potential (GWP), this work establishes a regression prediction method for atmospheric lifetime based on the highest occupied orbital energy, combined with molecular infrared spectroscopy theory. The model realizes GWP calculation of any gas, and the maximum error less than 19%. Secondly, this work starts from the collision phenomenon and establishes a theoretical evaluation method. Under the classical collision theory, the collision is reduced to potential scattering, and the molecular electrostatic potential is calculated. It is found that there is a strong correlation between positive potential surface area of small molecules and insulation, which can be used for quantitative analysis. Besides, the collision model considering the quantum effect is studied, and finding that the low-energy resonance phenomenon can be used for qualitative analysis, for the results calculated by R matrix method of 15 gases show that only strong insulation gases such as SF6 can exhibit low-energy resonance.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130882769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[ICEPE-ST 2022 Virtual Website Home Page] [icpe - st 2022虚拟网站首页]
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/icepe-st51904.2022.9757060
{"title":"[ICEPE-ST 2022 Virtual Website Home Page]","authors":"","doi":"10.1109/icepe-st51904.2022.9757060","DOIUrl":"https://doi.org/10.1109/icepe-st51904.2022.9757060","url":null,"abstract":"","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"95 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132273815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mechanical Feature Extraction of High Voltage Circuit Breaker based on Machine Vision 基于机器视觉的高压断路器机械特征提取
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757125
Dingge Yang, Bo Niu, Sheng Lei, Xueli Wang, Yakui Liu, Guogang Zhang
{"title":"Mechanical Feature Extraction of High Voltage Circuit Breaker based on Machine Vision","authors":"Dingge Yang, Bo Niu, Sheng Lei, Xueli Wang, Yakui Liu, Guogang Zhang","doi":"10.1109/ICEPE-ST51904.2022.9757125","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757125","url":null,"abstract":"The contact displacement and speed curves are tightly linked to the performance of circuit breaker, which are key parameters of site test and widely used in the mechanical identification and prediction model of high voltage circuit breaker. In the traditional methods, acceleration or displacement sensors are installed on the insulated pull rod to measure the contact displacement. However, when the above methods are implemented at the site operation, the installation and disassembly of sensors greatly reduces the efficiency of mechanical characteristics test of the circuit breaker. In this paper, a mechanical feature extraction method for high voltage circuit breaker is proposed based on machine vision. Firstly, a high-speed camera is employed to record the video of the action process of spring operating mechanism, in which the insulated pull rods, crank arms, and many other critical parts are included. Secondly, the library function of computer vision OpenCV is used to read frame by frame and split the video into a time-lapse series of images and the optical flow method is applied to analyze the captured images to track the moving corner point and realize its feature extraction after the image preprocessing operation of filtering and noise reduction. Then, taking the point from the crank arm of operating mechanism as a corner, the angle displacement curve and angular speed curve of crank arm can be obtained. Finally, the contact displacement and other mechanical characteristics are calculated from the movement curve of crank arm, which could provide evidences for the condition assessment of high voltage circuit breaker. According to the non-contact measurement based on the machine vision, the adverse effects of mechanical sensors mounted inside circuit breaker could be avoided. Moreover, the proposed method provides a feasible way to evaluate the mechanical characteristics of a live circuit breaker in the field operating environment.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"132 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123492657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparsion of CO2 Nozzle Arc Simulation During Current Zero Period based on the Non-CE and LTE Models 基于非ce和LTE模型的零电流期CO2喷嘴电弧仿真比较
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9756985
Yushi Zhang, Haonan Sun, Yi Wu, Yanwei Nan, M. Rong
{"title":"Comparsion of CO2 Nozzle Arc Simulation During Current Zero Period based on the Non-CE and LTE Models","authors":"Yushi Zhang, Haonan Sun, Yi Wu, Yanwei Nan, M. Rong","doi":"10.1109/ICEPE-ST51904.2022.9756985","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9756985","url":null,"abstract":"The dynamic arc behavior during the current zero (CZ) period is different from that of the arc burning stage. The rapid decay of temperature leads to a rapid decrease in the chemical reaction rate inside the arc plasma. Therefore, a new numerical model needs to be established to reflect the non-chemically equilibrium (non-CE) effect on the arc decay process. The dynamic behavior of CO2 nozzle arc was investigated in the established non-CE model from two aspect: (1) the macroscopic behavior which includes the arc temperature decay and the change of enthalpy. (2) the microscopic mechanism which includes the particle composition, non-equilibrium degree and the decay process of electron number density.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123606132","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Intelligent Diagnosis of GIS Partial Discharge via Stacked Autoencoder and Transfer Learning 基于堆叠自编码器和迁移学习的GIS局部放电智能诊断
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757056
Q. Jing, Jielu Yan, Ruixin He, Yifan Xu, Lei Lu
{"title":"Intelligent Diagnosis of GIS Partial Discharge via Stacked Autoencoder and Transfer Learning","authors":"Q. Jing, Jielu Yan, Ruixin He, Yifan Xu, Lei Lu","doi":"10.1109/ICEPE-ST51904.2022.9757056","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757056","url":null,"abstract":"Accurate and reliable fault analysis is essential to improve the performance of gas-insulated switchgear (GIS) and ensure the safe and stable operation of the power system. Advances in the perception and measurement technology of power primary equipment have increased the scale of GIS operation and fault data. Driven by massive samples, deep learning has brought new opportunities for GIS fault identification and intelligence diagnosis. As an unsupervised learning method, stacked autoencoder (SAE) can automatically extract representative expressions and in-depth features from massive unlabeled data. Consequently, it can effectively alleviate the problems of incomplete data category labels and limited data samples. Meanwhile, transfer learning can avoid the need to train the model from scratch under the new dataset. For this reason, this paper combines SAE with transfer learning to realize partial discharge (PD) pattern recognition of GIS in order to solve the problem of complex and variable and large randomness of the on partial discharge samples. Unsupervised greedy layer-wise pre-training and supervised fine-tuning are leveraged to train the SAE model. The experimental data was generated using four types of PD in the laboratory. The optimal SAE structure is trained under the source domain, and the GIS PD pattern recognition under the target domain is realized through transfer learning. Experimental results show that the proposed method has stronger robustness and generalization while improving the accuracy of partial discharge pattern recognition of GIS.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"131 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125440531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Post-arc Dielectric Recovery of Ultrahigh-Pressure Nitrogen Under Forced Gas Flow 强迫气体流动下超高压氮气弧后介电回收
2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) Pub Date : 2022-03-15 DOI: 10.1109/ICEPE-ST51904.2022.9757118
Fahim Abid, K. Niayesh, N. Støa-Aanensen, E. Jonsson
{"title":"Post-arc Dielectric Recovery of Ultrahigh-Pressure Nitrogen Under Forced Gas Flow","authors":"Fahim Abid, K. Niayesh, N. Støa-Aanensen, E. Jonsson","doi":"10.1109/ICEPE-ST51904.2022.9757118","DOIUrl":"https://doi.org/10.1109/ICEPE-ST51904.2022.9757118","url":null,"abstract":"In this paper, the impact of forced cooling on the dielectric recovery of ultrahigh pressure nitrogen arc is experimentally investigated. The dielectric recovery is studied by applying 10-kV high voltage pulse at different instances after current zero. The current amplitude and the half cycle duration are kept at 425 A and 540 µs respectively. To examine the pressure dependence on the dielectric recovery, three different pressure cases are investigated: 1, 20 and 40 bar. First, dielectric recovery of nitrogen arc is studied without forced cooling by adopting a free-burning arrangement at different filling pressures. Afterwards, a puffer arrangement is used to investigate the impact of forced cooling on dielectric recovery. When the puffer arrangement is used, the position of the puffer disc and the blowing pressure are recorded. It is found from the experiment that, the arc voltage before current zero rises because of enhanced cooling due to forced gas flow. Unlike free-burning arcs where the dielectric recovery just after current zero, i.e., the thermal phase, is found to deteriorate in case of higher filling pressures of 20 bar and 40 bar, the gas flow generated from puffer with high filling pressure significantly improves the recovery process even in the thermal phase.","PeriodicalId":424834,"journal":{"name":"2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"PP 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126537008","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书