{"title":"Sustainable and Durable Reinforced Concrete Construction","authors":"Corinaldesi, G. Moriconi, F. Tittarelli","doi":"10.14359/12500","DOIUrl":"https://doi.org/10.14359/12500","url":null,"abstract":"Recycled aggregates used in combination with high-volume fly ash is an example of sustainable construction material usage as it represents a judicious use of resources by recycling by-products, which results in a lower environmental impact through reduced carbon dioxide (CO2) emissions and reduced natural aggregate extraction. The related concrete mixtures yield acceptable mechanical performance. The aim of the experimental work reported herein was to study the effect of recycled aggregate and/or fly ash on carbonation and chloride penetration depth, as well as the effect on corrosion behavior of either bare or galvanized steel in cracked reinforced concrete (RC). The concrete mixture contained equal amounts of fly ash and cement. Results show that introduction of the sustainability concept in concrete technology by using recycled aggregate and/or fly ash did not cause any deleterious effects on durability of RC specimens in terms of both chloride and CO2 penetration, and reinforcement corrosion in cracked concrete.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121206472","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of the Variation of Cement Source on Hot Weather Concreting","authors":"G. A. Arenes-Oliva, M. Bergin, A. Zayed","doi":"10.14359/12522","DOIUrl":"https://doi.org/10.14359/12522","url":null,"abstract":"This work studied effects of varying cement source on fresh and hardened concrete properties under hot weather conditions. For the 7 ASTM Type II cements studied, the same mix proportioning was adopted at a mixing temperature of 95 deg F with a constant dosage of water reducing and air entraining admixtures. Properties of fresh concrete including slump loss over an extended mixing period of 90 minutes, air content, and setting times are reported. Hardened properties including compressive strength development and rapid chloride permeability test data are also reported. Results indicate that the rate of slump loss and setting times are affected by cement compound composition, calcium sulfate content, and calcium sulfate type. Compressive strength, under hot mixing conditions, is found to be dependent on composition, fineness, and morphology of cement compounds.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126000562","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of Shrinkage Reducing Admixtures on Drying Shrinkage of Concrete","authors":"C. Videla, C. Aguilar","doi":"10.14359/12508","DOIUrl":"https://doi.org/10.14359/12508","url":null,"abstract":"This work aimed to verify the feasibility of reducing the drying shrinkage of concrete made with portland pozzolan cement. Major variables included slump, shrinkage-reducing admixture (SRA) brand and dosages, and specimen dimensions. Tests were conducted on 132 prism specimens and shrinkage strains were measured up to 360 days of drying. Compressive and splitting strength and static modulus of elasticity were also determined. Based on the obtained results, it was concluded that all 5 of the brand admixtures evaluated reduce drying shrinkage. One experimental admixture exhibited the best behavior and reduced up to 45% of the average free shrinkages of concrete at 360 days of drying. Results were compared with drying strain predictions of ACI, CEB, B3, GL, Sakata, and Sakata 2001 models. It was concluded that, in general, all the analyzed shrinkage models do not adequately represent the observed shrinkage behavior of concretes made with portland pozzolan cement and SRAs. Therefore, 2 prediction models to estimate drying shrinkage strains were developed based on ACI drying-time function and Sakata's ultimate shrinkage strain. One of the models is for use at a design level when no information about a particular SRA is known, and the other is applicable to concrete made with a particular admixture brand.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124224178","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Self-Consolidating Concrete Piles Confined in FRP Tubes","authors":"H. El-Chabib, M. Nehdi, M. H. Naggar","doi":"10.14359/12507","DOIUrl":"https://doi.org/10.14359/12507","url":null,"abstract":"Cast-in-place deep foundations such as drilled shafts and piers are often subjected to 2 sources of problems. First, the integrity and uniformity of the cross-sectional area of these structural elements cannot be assured using normal concrete due to limited accessibility and visibility during construction. Cavities and soil encroachments leading to soil pockets can impair their load-bearing capacity. Second, corrosion problems of steel reinforcement in deep foundations have been costly, requiring annual repair costs of more than $2 billion in the U.S. alone. To address these 2 challenges, a novel technology for the construction of drilled shaft concrete piles is proposed herein. Self-consolidating concrete, a material that compacts under its own weight without vibration, bleeding, or segregation, is used to assure the structural integrity/uniformity of cross-sectional areas of deep foundations. The self-consolidating concrete is cast into FRP envelopes, which provide corrosion-resistant reinforcement. This paper also presents results of a lab study on the mechanical performance of these novel piles, including the effect of using expansive cement and shrinkage reducing admixtures to enhance the FRP tube-concrete interfacial bond.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"461 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123648251","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Behavior of Flared-Column Bents Under Seismic Loading","authors":"H. Nada, D. Sanders, M. Saiidi, S. El-Azazy","doi":"10.14359/12498","DOIUrl":"https://doi.org/10.14359/12498","url":null,"abstract":"It has been determined from past earthquakes that flared columns are susceptible to premature shear failure. In the 1999 California Northridge event, some shear failures were caused by a plastic hinge formation occurring at the base of the flare and a subsequent increase in the level of column shear demand above design levels. This paper presents an experimental and analytical study designed to examine new details for flared columns and joints. Primary features are a gap at the top of the column and the amount of transverse flare reinforcement. Two, 2-column bents were tested on the shake table to study dynamic effects as well as column and beam interaction. Test specimens had different amounts of confining reinforcement in the flare. The detail demonstrated overall ductility that is above the minimum limit recommended by current specifications. Tests also showed that gap started to close at ductility levels below the recommended limit.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124484954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance-Based EvaIuation of Rectangular RC Structures Using a Flexible Diaphragm Model","authors":"J. Barron, M. B. Hueste","doi":"10.14359/12525","DOIUrl":"https://doi.org/10.14359/12525","url":null,"abstract":"","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130847383","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Spectral Response of Mortar Surfaces During Curing","authors":"L. Kindervater, R. Luna, A. Belarbi","doi":"10.14359/12529","DOIUrl":"https://doi.org/10.14359/12529","url":null,"abstract":"A series of experiments were identified to analyze the spectral response of laboratory prepared surfaces, primarily of materials with a mineralogical origin, including soil, aggregate, and concrete. This paper presents the experimental procedure and results of a series of tests performed on a mortar mixture. Temperature, strength, and spectral reflectance were measured for a period of time during the curing of the mortar. Results revealed apparent correlations between temperature, water content (curing rate), and spectral response.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133150351","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Joukoski, K. F. Portella, Carlos M. García, Almir Sales, O. Baron, J. D. Paula
{"title":"\"Study of the Influence of Cement Type, Cement Content, and Concrete Cover Thickness on the Resistance and Durability of Concretes Subjected to Chloride Ion Aging\"","authors":"A. Joukoski, K. F. Portella, Carlos M. García, Almir Sales, O. Baron, J. D. Paula","doi":"10.14359/12506","DOIUrl":"https://doi.org/10.14359/12506","url":null,"abstract":"Reinforced concrete (RC) structures built in coastal zones have constantly been threatened by environmental damaging elements. The chloride ion is known as one of the most aggressive of these elements, causing, among other types of damage, corrosion of the steel reinforcement and degradation of concrete. The aim of this work was to determine the influence of the cement type and cement content, as well as the concrete cover thickness, in resistance and durability of RC elements exposed to aging in a 3.4% sodium chloride aqueous solution. Evaluation of the concrete behavior was taken from the results of physical and mechanical tests of cylindrical concrete samples and electrochemical tests--mainly the electrochemical impedance spectroscopy--of small prismatic RC samples. The results are presented for each combination of cement type and content, in terms of aging time.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114602206","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance of High-Volume Fly Ash Concrete in Hot Weather","authors":"P. K. Mehta","doi":"10.14359/12493","DOIUrl":"https://doi.org/10.14359/12493","url":null,"abstract":"A serious problem associated with modern portland cement concrete structures is thermal cracking, especially cast-in-place massive elements made with relatively high cement content and cured under hot weather conditions. From theoretical considerations and field tests it has been concluded that blended portland cement concrete mixtures containing 50% or more ASTM Class F fly ash by mass of the total cementitious material perform much better under these conditions.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130653835","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Shear Stud Performance of Lightweight Polystyrene Concrete Composite Sections","authors":"Y. Lin, J. Ingham, J. Butterworth","doi":"10.14359/12496","DOIUrl":"https://doi.org/10.14359/12496","url":null,"abstract":"An experimental study was carried out at the University of Auckland to quantify the performance of shear studs embedded in composite ribbed slabs, formed by casting lightweight polystyrene concrete onto profiled steel decking. 18 tests were conducted using a new type of push-off test rig, with test units composed of either lightweight polystyrene concrete or normal weight concrete. This paper reports and discusses the main results of those 18 tests. Results indicate that in most cases, designs utilizing lightweight polystyrene concrete had considerable ductility and shear capacity. Recommended design provisions based on the experimental data are presented.","PeriodicalId":423205,"journal":{"name":"\"SP-209: ACI Fifth Int Conf Innovations in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Con\"","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2002-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126676972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}