{"title":"FE Evaluation of Pedestrian and Worker Fall Incidents — the Evolution of Analysis Techniques and Safety Requirements","authors":"Christopher Shiver","doi":"10.51501/jotnafe.v41i1.123","DOIUrl":"https://doi.org/10.51501/jotnafe.v41i1.123","url":null,"abstract":"Fall injury and fatality claims and legal cases involving ordinary pedestrians as well as employees/contractors at work sites have increased dramatically over the course of the author’s 43-year engineering career. As a result, forensic engineers are frequently being contacted by insurers and attorneys to analyze these incidents. The need is to determine probable cause(s) and ascertain as to whether location features were designed, constructed, installed, manufactured, and/or maintained in accordance with the standard of care, including requirements specified in applicable codes and standards. The proper contemporary analysis techniques for these incidents are addressed in this paper as well as what constitutes proper basis for establishing a standard of care for involved installations and/or equipment. It will also expand on and update information provided in approximately two dozen past NAFE papers on various aspects of fall incident analysis, most of which are more than 10 to 30 years old.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":" 27","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141833708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Forensic Investigations of Low-Clamp-Force Type Wheel Separations","authors":"Mark Bailey, Dwayne Toscano","doi":"10.51501/jotnafe.v41i1.900","DOIUrl":"https://doi.org/10.51501/jotnafe.v41i1.900","url":null,"abstract":"Wheel separations are a common non-operator cause of damage and injury in road transport systems. Forensic investigators are often engaged to determine why a wheel separated from a moving vehicle. In 100 investigations, the authors observed wheel separations due to axle, bearing, or fastener system failures. Fastener system failures dominate, and the authors show that low fastener clamp force is their necessary and sufficient condition. Examples of physical evidence of low fastener clamp force commonly found in forensic investigations are presented. The reasons for low fastener clamp force are explored using known wheel installation-to-separation times and distances, torque audits, and interface corrosion. From these, it is often possible to form a sound explanation for a low-clamp-force type wheel separation. Finally, wheel nut re-torquing is identified as a probable effective measure in preventing low-clamp-force type wheel separations.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":" 18","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141833813","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Distracted Driving: Determining Cell Phone Usage from Forensic Cellular Records","authors":"Mark McFarland","doi":"10.51501/jotnafe.v41i1.893","DOIUrl":"https://doi.org/10.51501/jotnafe.v41i1.893","url":null,"abstract":"This paper presents an analysis of an alleged texting-while-driving collision case involving cellular call records. The plaintiff’s expert, unfamiliar with cellular networks, made serious errors in interpreting the cellular records, which resulted in a mischaracterization of the defendant’s cell phone usage at the time of the collision. Thus, the plaintiff’s expert could not support his opinion that the defendant was using her phone at the time of the collision. The expert made three critical mistakes interpreting the cellular records — mistakes that are commonly made by analysts who are unfamiliar with the design and operation of cellular phone networks. This paper explains the common mistakes and faulty assumptions behind them. The proper analysis methods of a qualified engineer with an understanding of cellular networks are also presented.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":" 24","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141833920","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Subjects’ Ability to Characterize g’s in Relation to Activities of Daily Living","authors":"William Lee","doi":"10.51501/jotnafe.v41i1.899","DOIUrl":"https://doi.org/10.51501/jotnafe.v41i1.899","url":null,"abstract":"The amount of force associated with a specific activity or event often utilizes g’s (g-force) and the unit of force. In litigation, biomechanics forensic experts provide general causation analysis of injury events, referencing the g’s of the event and often the g’s associated with Activities of Daily Living (ADLs). It is assumed that jurors will understand and correctly interpret any presented g values. This research explored the validity of this assumption. A survey instrument was employed that included 610 subjects to probe an individual’s understanding of what g’s are and their beliefs of the associated magnitude of ADL g’s. The results indicated that most adults have a limited understanding of g’s, often holding incorrect beliefs. For example, many believe they do not experience 2 or 3 g’s during daily activities. Therefore, it is useful for the engineering expert to frame g-based analysis with references to ADLs, providing individuals (and jurors) with a proper framework to understand the analysis results. Without such reference points, jurors may misunderstand — and attorneys can misrepresent — the meaning of any g’s associated with the specific case analysis.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":" 96","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141833693","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Methodology for Reconciliation of Different Forms of Electronic Data in Vehicle Collision Reconstruction","authors":"Shawn Ray","doi":"10.51501/jotnafe.v40i2.837","DOIUrl":"https://doi.org/10.51501/jotnafe.v40i2.837","url":null,"abstract":"Collision analysis utilizing electronic data recorders, videos, traffic signal timing data, and other electronic records adds valuable input but can be a challenge to tie together due to the lack of a finite time stamp or common recording rate. However, overlapping data streams that have a common point-in-time identifier can be resolved. A strategic approach was developed by the author for unifying and validating the vehicle positions and time-distance reconstruction. The method outlines the steps for establishing known data points, forming a common time line, identifying overlapping information, and linking together independent records. A case study demonstrates a crash at a traffic signal-controlled intersection in which each vehicle entered on their respective green lights without conflict; however, the collision still occurred. The crash reconstruction will highlight driver options and demonstrate the value of combining multiple data streams into one time line.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":"92 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139530136","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"FE Investigation of Design and Quality Control-Related Issues Contributing to Metal-On-Metal Hip Implant Failures","authors":"Olin Parker, Jahan Rasty, Matthew Mills","doi":"10.51501/jotnafe.v40i2.867","DOIUrl":"https://doi.org/10.51501/jotnafe.v40i2.867","url":null,"abstract":"High levels of cobalt and chromium ions were detected in the bodies of multiple recipients of modular cobalt chrome molybdenum metal-on-metal hip implants, necessitating the revision of their implants. A forensic engineering investigation of provided discovery documents and existing literature regarding the design, manufacturing, and clinical testing of these modular hip implants was performed. The investigation revealed that the modular interfaces of the implant allowed for micromotion to induce mechanically assisted crevice corrosion at these surfaces. The debris from this corrosion resulted in the release of metal ions into the bodies of the users, forming pseudotumors and compromising the user’s health and wellbeing. The effect of this corrosion was enhanced by the galvanic couple that existed between the modular components of the implant. In addition, scanning electron microscopy (SEM) and electron dispersive spectroscopy (EDS) analysis identified silicon carbide (SiC) and aluminum oxide (AL2O3 ) particles left behind from polishing, which were embedded in the ball and liners. These particles accelerated the wear of the hip implant and further exacerbated the release of metal ions. The designers of future hip implants should take care in preventing the occurrence of the above-stated factors.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":"56 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139530789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Factors to Consider in Developing Conceptual Scopes of Repair for Common Low-Slope Roofing Assemblies","authors":"Chad Williams, Drew Jamison","doi":"10.51501/jotnafe.v40i2.820","DOIUrl":"https://doi.org/10.51501/jotnafe.v40i2.820","url":null,"abstract":"Forensic engineers are commonly asked to develop conceptual scopes of repair as part of their work. Many factors impact these recommendations, including building codes, construction feasibility, manufacturer assessment, and installation requirements. In addition, the conditions present on and within the existing roof surfaces can limit the repairability of a commercial roof assembly such that removal and replacement of the entire roof section is the appropriate or only feasible repair option. This paper will focus on common limitations to be considered when developing a conceptual scope of repair for common commercial roof systems, including single-ply membranes, built-up roofing, metal panel roofing, spray polyurethane foam roofing, and the application/maintenance of roof coatings. It will also discuss an assessment methodology that can assist in developing a broader understanding of the condition of the roof surfaces.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":"94 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139530118","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Utilizing ASCE/SEI 7 to Estimate Wind Speeds for Forensic Investigations","authors":"Lucas Pachal, Paul Warner","doi":"10.51501/jotnafe.v40i2.891","DOIUrl":"https://doi.org/10.51501/jotnafe.v40i2.891","url":null,"abstract":"The American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI) 7 standard is utilized to determine design wind loading on buildings and other structures. However, it can also be utilized in a forensic capacity to approximate a wind speed that would cause specific conditions to occur, such as the overturning of a structure. This paper provides a brief overview of the ASCE/SEI 7 method for wind loading and discusses the use of various adjustment factors used to determine the wind on structures, including wind directionality factor, velocity pressure coefficient, topographic factor, and the ground elevation factor. A clear understanding of these factors — and how to apply them — is crucial to estimating a wind speed and resulting force to cause a particular event or condition to occur.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":"55 2","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139530792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Forensic Engineering Investigation of a Machine Guarding-Related Injury","authors":"Jason McPherson","doi":"10.51501/jotnafe.v40i2.853","DOIUrl":"https://doi.org/10.51501/jotnafe.v40i2.853","url":null,"abstract":"OSHA regulations and industry-accepted standards are intended to be used in conjunction to help prevent worker injury. Despite the aforementioned intention, a point of operation injury occurred to an employee while he was operating a hydraulic rotary bending machine. The machine had been retrofitted with a two-hand control device that was intended to act as a means of point of operation safeguarding. A forensic engineering analysis of both the electromechanical design and programmable logic code — combined with a performance and prescriptive requirement analysis — ultimately revealed flaws in the design of the electromechanical system and software design. It also demonstrated a lack of adherence to the applicable industry-accepted standards related to machine guarding. These factors led to the point of operation injury.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":"10 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140508657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"FE Investigation of Maintenance and Operational Factors Contributing to the Collapse of a Crane Boom","authors":"Olin Parker, Jahan Rasty, Matthew Mills","doi":"10.51501/jotnafe.v40i2.868","DOIUrl":"https://doi.org/10.51501/jotnafe.v40i2.868","url":null,"abstract":"During the coating of a natural gas pipeline, all 14 bolts securing the pedestal of a crane boom to a truck bed failed, causing the boom to fall and strike a worker in the head. The bolts exhibited excessive corrosion indicative of exposure to a harsh corrosive environment prior to the failure. Review of provided documents revealed that the crane was kept in an uncovered yard for two years. Afterward, it was rented to petrochemical companies for use in heavy oil and gas industrial environments. The fracture surfaces of the bolts revealed signs of excessive fatigue, which were determined to be caused by loadings that the previous renters of the crane had subjected it to. Bolt fatigue drastically reduced their strength, allowing them to fail under loads well below the recommended load capacity of the crane. Maintenance records indicated that the lessor failed to perform adequate inspection of the crane, allowing bolt corrosion and fatigue to go unnoticed. Had proper inspections and maintenance instructions been provided and performed, the incident would not have occurred.","PeriodicalId":420132,"journal":{"name":"Journal of the National Academy of Forensic Engineers","volume":" 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139623514","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}