Volume 5A: Heat Transfer最新文献

筛选
英文 中文
Predictions of Impingement Heat Transfer With Dimples, Pin-Fins and Zig-Zag Rib Obstacles: Conjugate Heat Transfer Computational Fluid Dynamics Predictions 与酒窝,销鳍和锯齿形肋障碍的碰撞传热预测:共轭传热计算流体动力学预测
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-90730
A. M. El-jummah, G. Andrews, J. Staggs
{"title":"Predictions of Impingement Heat Transfer With Dimples, Pin-Fins and Zig-Zag Rib Obstacles: Conjugate Heat Transfer Computational Fluid Dynamics Predictions","authors":"A. M. El-jummah, G. Andrews, J. Staggs","doi":"10.1115/gt2019-90730","DOIUrl":"https://doi.org/10.1115/gt2019-90730","url":null,"abstract":"\u0000 Regenerative cooling of low NOx gas turbine combustors was investigated using impingement heat transfer with all the combustion air used for wall cooling prior to passing to the flame stabiliser. 10 rows of impingement holes were modelled. Three obstacles were compared with smooth wall impingement heat transfer. The CHT/CFD methodology used was that validated against experimental results in previous publications of the authors. The impingement heat transfer enhancement geometries investigated were circular pin-fins, dimples and zig-zag ribs, which were aligned transverse to the direction of the cross-flow on the impingement target surface. The obstacles were equally spaced on the centre-line between each row of impingement jets transverse to the cross-flow. One heat transfer enhancement obstacle was used per impingement jet air hole. The CFD calculations were carried out for an air mass flux G of 1.08, 1.48 and 1.94 kg/sm2bara, which are the high flow rates used for regenerative combustor wall cooling. Comparison of the current CFD predictions and previous CFD work, that have experimental data, were made for the flow pressure loss and the surface and locally X2 average HTC, h. It was concluded that none of the obstacles in the impingement gap a significant increase in the surface averaged heat transfer coefficient (HTC). The impact of the obstacles was to increase the flow maldistribution due to the increased pressure loss. This resulted is less heat transfer from the reduced air mass flow in the first 4 holes and increased heat transfer in the last 4 holes, relative to the smooth wall results. The main effect of the obstacles was to increase the heat transfer to the impingement jet surface. The dimpled surface was predicted to have a very poor performance, with significantly reduced impingement heat transfer. This was due to the impingement jets being deflected away from the target surface by the shape of the dimples and this reduced the surface heat transfer.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124825149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Scaling Flat Plate, Low Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio 用平流容量比计算平板的低温绝热效果
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-90997
Jacob P. Fischer, J. L. Rutledge, Luke J. McNamara, M. Polanka
{"title":"Scaling Flat Plate, Low Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio","authors":"Jacob P. Fischer, J. L. Rutledge, Luke J. McNamara, M. Polanka","doi":"10.1115/gt2019-90997","DOIUrl":"https://doi.org/10.1115/gt2019-90997","url":null,"abstract":"\u0000 Effective design of film cooled engine components requires the ability to predict behavior at engine conditions. This is commonly accomplished through low temperature testing on scaled up geometries. The adiabatic effectiveness, η, is one indicator of the performance of a film cooling scheme. Performing an experiment to measure η in a low temperature wind tunnel requires appropriate selection of the coolant flow rate. Perhaps the most common flow rate parameter that is used to characterize the coolant flow relative to the freestream is the mass flux ratio, or blowing ratio, M. This is usually used in lieu of the velocity ratio to account for the fact that the density of the coolant is typically much larger than that of the hot freestream gas. Numerous studies have taken place evaluating the ability of M to properly scale the effects of density ratio and its performance has produced mixed results. The momentum flux ratio, I, is an alternative that is also found to have mixed success, leading some to recommend matching the density ratio to allow simultaneous matching of M and I. Nevertheless, widely varying results in the literature regarding the efficacy of these coolant flow rate parameters to scale the density ratio suggests there may be other largely ignored effects playing a role in the thermal physics.\u0000 In the present work, thermal experiments were performed to measure adiabatic effectiveness on a flat plate with a single 7-7-7 shaped hole. Various coolant gases were used to give a large range of thermodynamic property variations. It is shown that a relatively new coolant flow rate parameter that accounts for not only density variations but also specific heat variations, the advective capacity ratio (ACR), far exceeds the ability of either M or I to provide matched adiabatic effectiveness between the various coolant gases that exhibit extreme property differences. Particularly considering that the specific heat of the coolant in an engine is significantly lower than the specific heat of the freestream gas, ACR is shown to be appropriate for characterizing non-separating coolant flow situations.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116237753","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Experimental Study on Overall Cooling Effectiveness of Swirl-Stabilized Model Combustor With Effusion Cooling 射流冷却下旋流稳定模型燃烧室整体冷却效果的实验研究
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-91080
Y. Ji, L. Zhang, M. Jin, B. Ge, S. Zang, J. Xin, Wei-liang Wu, Mingjia Li, Wenyan Xu
{"title":"Experimental Study on Overall Cooling Effectiveness of Swirl-Stabilized Model Combustor With Effusion Cooling","authors":"Y. Ji, L. Zhang, M. Jin, B. Ge, S. Zang, J. Xin, Wei-liang Wu, Mingjia Li, Wenyan Xu","doi":"10.1115/gt2019-91080","DOIUrl":"https://doi.org/10.1115/gt2019-91080","url":null,"abstract":"\u0000 Application of effusion cooling or effusion based compound cooling in the state of art gas turbine combustor is more and more common, especially in aero-engines. A linearly arranged planar optically accessible three-nozzle lab scale combustor equipped with perforated testing plate for cooling is designed. Overall cooling effectiveness is experimentally examined as the key indicator of cooling performance at non-reacting flow conditions. Main air is electrically heated to about 573K. Temperature of perforated liner is recorded by the short-wave infra camera with careful calibration. Effect of effusion hole inclination angle is investigated by comparing at forward (30°), normal (90°) and backward (150°) cases. Pressure drop across the nozzle is set to be 3%, 4% and 5% respectively and that is 0–2.5% for the effusion plate. The main purpose of this work is to characterize combustor liner effusion cooling capacity at conjugate heat trasnfer conditions, and backward cooling configuration is firstly investigated.\u0000 Results clearly show that effusion cooling behavior is strongly influenced by main swirling flow regime near the combustor liner wall. To be specific, three zones as Corner Recirculation Zone (CRZ), Impinging Zone (IZ) and Developing Zone (DZ) can be divided. IZ is the region which we should treat carefully for liner cooling design because it sustains the highest heat load. Generally, inclined holes perform better cooling characteristics than normal ones. The important observation is that backward injections reveal “anti-impinging” ability, which can enhance the cooling effectiveness in upstream CRZ and IZ greatly with high coolant consumption. The potential drawback is that reverse cooling jets may induce intense interactions with main flow. But it is still a good choice for optimizing combustor effusion cooling, especially in swirling impinging regions.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114843190","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Aerothermal Simulations Comparisons of a Shaped-Hole Film Cooling Flow 形孔气膜冷却流的热模拟比较
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-90458
M. Simon, S. Gautier, Emmanuel Vanoli, P. Auzillon
{"title":"Aerothermal Simulations Comparisons of a Shaped-Hole Film Cooling Flow","authors":"M. Simon, S. Gautier, Emmanuel Vanoli, P. Auzillon","doi":"10.1115/gt2019-90458","DOIUrl":"https://doi.org/10.1115/gt2019-90458","url":null,"abstract":"\u0000 Film Cooling is a crucial technology for engine manufacturer to develop high-efficiency gas turbine engines by raising turbine entry temperature. A lot of cooling holes geometries have been studied in the past few years in tests, as well as numerical simulations. Shaped holes are nowadays a standard geometry for protecting the blades, given the performance improvement compared to cylindrical holes. Numerical correlation with physical tests is challenging due to the high sensitivity to thermal mixing and adequate boundary condition predictions.\u0000 This paper is devoted to numerical simulation comparisons of the 777 shaped holes configuration of Pennsylvania State University, for an incompressible flow with a density ratio of 1.5, a blowing ratio of 1.5 and a free stream turbulence intensity of 0.5%. Two different simulations have been chosen: a state-of-the-art RANS simulation with k-e Realizable model computed with ANSYS Fluent and a high fidelity solver Lattice-Boltzmann Method computed with Simulia PowerFLOW.\u0000 In order to improve the accuracy of numerical simulations against test results, this article deals with an aerothermal model of the complete test bench. This additional modeling allows to strongly improve thermal prediction and to understand initial discrepancies related to test bench environment.\u0000 Results show that k-ε Realizable simulation provides a good prediction of average effectiveness, but local differences appear due to inherent RANS modeling limitations. On the other hand, LBM simulation provides excellent results for both aerodynamic and thermal quantities: tests results are very well reproduced.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116425569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A Modular Transonic Turbine Cascade for Cooled Rotor Metal Effectiveness Investigations 用于冷却转子金属效能研究的模块化跨音速涡轮叶栅
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-91697
James A. Parker, E. Romero, T. Povey
{"title":"A Modular Transonic Turbine Cascade for Cooled Rotor Metal Effectiveness Investigations","authors":"James A. Parker, E. Romero, T. Povey","doi":"10.1115/gt2019-91697","DOIUrl":"https://doi.org/10.1115/gt2019-91697","url":null,"abstract":"\u0000 The Metal Effectiveness Rotor Cooling (MERC) facility at the University of Oxford is a new blow-down linear cascade tunnel developed for aerothermal research of turbine rotor blade and rotor platform cooling systems. A high level of engine similarity is achieved with matched Mach numbers, Reynolds numbers, coolant-to-mainstream pressure ratios, and Biot number (using DMLS components of appropriate conductivity). The modular working section includes five blade passages, including platform and fir tree root geometries, and engine representative hub seals. The facility is designed to allow high accuracy IR camera measurement of the blade and platform surfaces (for metal effectiveness measurements) and downstream area traverse measurements. Detailed traverse measurements are possible in a single run, because of the long run time of the facility (up to 5 minutes).\u0000 The facility is being used for development and optimisation research of novel blade and platform cooling systems, with an emphasis on overall thermal performance of parts (metal effectiveness). Modular cassettes allow the blade components to be rapidly interchanged, and for variations to the designs of the front and rear hub seals. The engine representative seals and coolant feed paths allow for all engine leakage flows to be replicated in the experiment. This is important, because they are influential in determining the platform cooling flow structure (character and extent of secondary flow) and overall metal effectiveness result. Coolant supplied to each of the hub seals, and blade shank pocket can be independently varied to achieve required mass flows and pressure ratios. Rotor blades are typically manufactured using DMLS, allowing fast development and optimisation of fully-featured cooling systems at significantly reduced cost compared to traditional casting techniques.\u0000 To demonstrate the capability of the new facility, we present full-surface metal-effectiveness measurements of the rotor blade platforms (post-processed using high-accuracy infrared thermography techniques separately developed at the University of Oxford.)\u0000 The purpose of this paper is to outline the capabilities of the facility, describe the prior work and research context which led to its development, and to demonstrate the accuracy of the measurement techniques employed by presenting typical measured data. An argument is made for the importance of including realistic hub seal leakage paths in experiments investigating platform cooling flows by illustrating their significant impact on overall cooling performance. The MERC facility is a response to the need to develop more advanced rotor platform cooling schemes for future engines.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"15 8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131080413","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Finite Element Transient Modelling for Aero-Thermo-Mechanical Analysis of Whole Gas Turbine Engine 燃气轮机整体气动-热-力学分析的有限元瞬态建模
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-91278
Sabrina Giuntini, A. Andreini, B. Facchini
{"title":"Finite Element Transient Modelling for Aero-Thermo-Mechanical Analysis of Whole Gas Turbine Engine","authors":"Sabrina Giuntini, A. Andreini, B. Facchini","doi":"10.1115/gt2019-91278","DOIUrl":"https://doi.org/10.1115/gt2019-91278","url":null,"abstract":"\u0000 It is here proposed a numerical procedure aimed to perform transient aero-thermo-mechanical calculations of large power generation gas turbines.\u0000 Due to the frequent startups and shutdowns that nowadays these engines encounter, procedures for multi-physics simulations have to take into account the complex coupled interactions related to inertial and thermal loads, and seal running clearances. In order to develop suitable secondary air system configurations, guarantee structural integrity and maintain actual clearances and temperature peaks in pre-established ranges, the overall complexity of the structure has to be reproduced with a whole engine modelling approach, simulating the entire machine in the real operating conditions.\u0000 In the proposed methodology the aerodynamic solution providing mass flows and pressures, and the thermo-mechanical analysis returning temperatures and material expansion, are performed separately. The procedure faces the aero-thermo-mechanical problem with an iterative process with the aim of taking into account the complex aero-thermo-mechanical interactions actually characterizing a real engine, in a robust and modular tool, combining secondary air system, thermal and mechanical analysis. The heat conduction in the solid and the fluid-solid heat transfer are computed by a customized version of the open source FEM solver CalculiX®. The secondary air system is modelled by a customized version of the embedded CalculiX® one-dimensional fluid network solver.\u0000 In order to assess the physical coherence of the presented methodology the procedure has been applied to a test case representative of a portion of a real engine geometry, tested in a thermal transient cycle for the assessment of the interaction between secondary air system properties and geometry deformations.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"07 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128999996","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Numerical Study on Flow and Heat Transfer Characteristics of Discrete Film Cooling Holes of the Sinusoidal Longitudinal Corrugated Heat Liner 正弦纵向波纹热管离散膜冷却孔流动与传热特性的数值研究
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-90575
Zhi-peng Xu, Hui-ren Zhu, Ya-zhou Wang, Xinyu Bian
{"title":"Numerical Study on Flow and Heat Transfer Characteristics of Discrete Film Cooling Holes of the Sinusoidal Longitudinal Corrugated Heat Liner","authors":"Zhi-peng Xu, Hui-ren Zhu, Ya-zhou Wang, Xinyu Bian","doi":"10.1115/gt2019-90575","DOIUrl":"https://doi.org/10.1115/gt2019-90575","url":null,"abstract":"\u0000 To understand film cooling flow fields and heat transfer characteristics of the longitudinal corrugated surface on afterburner heat liner, the numerical simulation was performed in approximate actual boundary conditions. The single hole and full film holes on the corrugated surface were investigated under different boundary conditions to study the heat transfer and discharge coefficient. The adverse pressure gradient on the leeward results in spanwise expansion of the airflow, while the favorable pressure gradient on the windward keeps the shape of the jet constant. The different hole spacing and hole row spacing in different positions of the corrugated surface should be considered due to the film covering characteristics. The film cooling holes at the same height on the leeward and windward share the similar laterally average effectiveness. The flow rate and discharge coefficient increase from crest to trough. Cross-flow has a negative influence on the discharge coefficient especially the inlet cross-flow. The cross-flow and discharge coefficient can be correlated with each other by a logarithmic function. The jet discharge coefficient on the windward surface is higher than that on the leeward surface, which is contrary to previous cognition. The reason is that the jet blocking causes the downstream pressure zone to advance, which counteracts and enhanced the siphon effect on the leeward and windward side respectively. As the inlet pressure of coolant increases, the film cooling effectiveness on the windward side is greatly improved in full film condition. However, it changes little on the leeward side.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128507824","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical Investigation of the Effect of Inlet Flow Angle on Film Cooling Performance for the Blade Tip With Suction Surface Squealer Rim 入口气流角对带吸力面尖轮叶尖气膜冷却性能影响的数值研究
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-91104
Zhiqiang Yu, Jianjun Liu, Chen Li, B. An
{"title":"Numerical Investigation of the Effect of Inlet Flow Angle on Film Cooling Performance for the Blade Tip With Suction Surface Squealer Rim","authors":"Zhiqiang Yu, Jianjun Liu, Chen Li, B. An","doi":"10.1115/gt2019-91104","DOIUrl":"https://doi.org/10.1115/gt2019-91104","url":null,"abstract":"\u0000 Numerical investigations have been performed to study the effect of incidence angle on the aerodynamic and film cooling performance for the suction surface squealer tip with different film-hole arrangements at τ = 1.5% and BR = 1.0. Meanwhile, the full squealer tip as baseline is also investigated. Three incidence angles at design condition (0 deg) and off-design conditions (± 7 deg) are investigated. The suction surface, pressure surface, and the camber line have seven holes each, with an extra hole right at the leading edge. The Mach number at the cascade inlet and outlet are 0.24 and 0.52, respectively. The results show that the incidence angle has a significant effect on the tip leakage flow characteristics and coolant flow direction. The film cooling effectiveness distribution is altered, especially for the film holes near the leading edge. When the incidence angle changes from +7 deg to 0 and −7 deg, the ‘re-attachment line’ moves downstream and the total tip leakage mass flow ratio decreases, but the suction surface tip leakage mass flow ratio near leading edge increases. In general, the total tip leakage mass flow ratio for suction surface squealer tip is 1% greater than that for full squealer tip at the same incidence angle. The total pressure loss coefficient of suction surface squealer tip is larger than that for full squealer tip. The full squealer tip with film holes near suction surface and the suction surface squealer tip with film hole along camber line show high film cooling performance, and the area averaged film cooling effectiveness at positive incidence angle +7 deg is higher than that at 0 and −7 deg. The coolant discharged from film holes near pressure surface only cools narrow region near pressure surface.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"217 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124290672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Investigation and Thermal Modeling of the Thermal Contact Resistance at a Steam Turbine Blade Root 汽轮机叶片根部接触热阻的研究与热建模
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-90769
Dennis Toebben, Alexander Goerner, P. Luczynski, M. Wirsum, W. Mohr, K. Helbig
{"title":"Investigation and Thermal Modeling of the Thermal Contact Resistance at a Steam Turbine Blade Root","authors":"Dennis Toebben, Alexander Goerner, P. Luczynski, M. Wirsum, W. Mohr, K. Helbig","doi":"10.1115/gt2019-90769","DOIUrl":"https://doi.org/10.1115/gt2019-90769","url":null,"abstract":"\u0000 Increasing load ramps and temperature gradients in steam turbines, especially during start-ups, have a high impact on the component lifetime. Calculation models are commonly used to predict the lifetime consumption during such start-up procedures. However, the changing energy landscape requires innovative solutions to increase the power plant flexibility. In order to accelerate the start-ups with a simultaneously reduced lifetime consumption, hot air can be used to keep the steam turbine warm during shut downs. The calculation of heat fluxes within the steam turbine is crucial for the accurate prediction of the thermal state and the resulting lifetime consumption. Improved models enable the determination of life cycles as exact as possible.\u0000 During warm-keeping and pre-warming operations, the steam turbine rotates slowly. Thus, low centrifugal forces lead to high thermal contact resistances (TCR) at the blade roots, which influence the temperature distribution at the lifetime limiting locations, e.g. blade grooves. The paper presents heat transfer correlations, which describe the TCR depending on the rotational speed of the rotor. For this purpose, an experimental setup is designed in order to investigate the influence of contact pressure, ambient pressure and surface properties. For the detailed investigation of the complex heat fluxes at the T-root, a 3D Finite-Elements (FE) model is developed. This model calculates the TCR and specific heat fluxes based on measurement data. On the basis of the detailed evaluation, different analytical heat transfer correlation approaches with respect to the application in an overall steam turbine model are developed. These heat transfer correlations are integrated into the FE model and validated with additional measurements.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123624499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Impact of a Combustor-Turbine Interface on Turbine Vane Aerodynamics and Film Cooling 燃烧室-涡轮界面对涡轮叶片空气动力学和气膜冷却的影响
Volume 5A: Heat Transfer Pub Date : 2019-11-05 DOI: 10.1115/gt2019-90359
A. Lerch, R. Bauer, J. Krueckels, M. Henze
{"title":"Impact of a Combustor-Turbine Interface on Turbine Vane Aerodynamics and Film Cooling","authors":"A. Lerch, R. Bauer, J. Krueckels, M. Henze","doi":"10.1115/gt2019-90359","DOIUrl":"https://doi.org/10.1115/gt2019-90359","url":null,"abstract":"\u0000 Optimizing the aero-thermal performance of the combustor-turbine interface is an important factor in enhancing the efficiency of heavy-duty gas turbines. Also, it is a key requirement to fulfill the lifetime in this hottest area of the gas turbine. Typically transition pieces of can combustors induce a highly non-uniform swirling flow at the turbine inlet. In order to better understand the impact of the non-uniform combustor flow at the first stage vanes, a combined experimental and numerical study was carried out.\u0000 The experimental facility consisted of a high speed linear cascade with four vane passages, including an upstream transition piece, which was representative of a heavy duty gas turbine can combustor-turbine interface geometry. The experiments were conducted at engine representative Mach numbers and film cooling effectiveness measurements were performed at three different blowing ratios.\u0000 CFD RANS simulations were undertaken using a commercial flow solver. The numerical model was first validated with the experimental data, using inlet traverse 5-hole probe measurements, pressure taps along the airfoil perimeter and oil flow visualization results.\u0000 The investigation shows that the position of the vane relative to the combustor transition piece has a significant impact on the vane aerodynamics and also film cooling behavior. This understanding was key to a robust first vane aerothermal design of the GT36.","PeriodicalId":413122,"journal":{"name":"Volume 5A: Heat Transfer","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123680205","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书