2015 Australasian Universities Power Engineering Conference (AUPEC)最新文献

筛选
英文 中文
A review of computer tools for analyzing the impact of electric vehicles on power distribution 分析电动汽车对电力分配影响的计算机工具综述
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324853
Khizir Mahmud, G. Town
{"title":"A review of computer tools for analyzing the impact of electric vehicles on power distribution","authors":"Khizir Mahmud, G. Town","doi":"10.1109/AUPEC.2015.7324853","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324853","url":null,"abstract":"This paper reviews the various computer tools that have been reported for modeling the impacts of electrical vehicles on the power distribution grid. Forty four computer tools have been identified and summarised to facilitate selection of the most appropriate tools for specific tasks. Typical applications of the tools include vehicle design, analysis, control, grid integration and impact, market scheduling, and energy management. No single tool addresses all requirements, however sufficient information is provided to enable researchers to choose the appropriate combination of tools to meet specific research objectives.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"100 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122617577","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Security analysis of interconnected AC/DC systems 交/直流互联系统的安全性分析
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324794
R. Eriksson
{"title":"Security analysis of interconnected AC/DC systems","authors":"R. Eriksson","doi":"10.1109/AUPEC.2015.7324794","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324794","url":null,"abstract":"This paper analyses N-1 security in an interconnected ac/dc transmission system using power transfer distribution factors (PTDFs). In the case of a dc converter outage the power needs to be redistributed among the remaining converter to maintain power balance and operation of the dc grid. The redistribution of power has a sudden effect on the power-flow in the interconnected ac system. This may cause overloading of lines and transformers resulting in disconnection of equipment, and as a consequence cascading failure. The PTDF is used as a method to analyze and avoid violating limits by in the dc voltage control design consider the power distribution for a converter outage. By proper design and utilizing the proposed method increases the N-1 security and the secure transfer limits. This article proposes a method which minimizes the 2-norm of the sum of the PTDFs with constraints of not violating any line or transformer limits. Simulations were performed in a model of the Nordic power system where a dc grid is placed on top. The simulation supports the method as a tool to consider transfer limits in the grid to avoid violate the same and increase the security after a converter outage.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117006549","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Comparison of battery models for energy storage applications on insular grids 孤岛电网储能应用的电池模型比较
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324861
E. Rodrigues, R. Godina, G. Osório, J. Lujano-Rojas, J. Matias, J. Catalão
{"title":"Comparison of battery models for energy storage applications on insular grids","authors":"E. Rodrigues, R. Godina, G. Osório, J. Lujano-Rojas, J. Matias, J. Catalão","doi":"10.1109/AUPEC.2015.7324861","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324861","url":null,"abstract":"This paper explores different modelling techniques for representing electrochemical energy storage devices in insular power grid applications. Particular attention is given to Thevenin based and not Thevenin based models. A case study involving two insular power systems with renewable generation are used to stand out the performance of the selected battery technologies: Lithium-ion (Li-ion), Nickel-Cadmium (NiCd), Nickel-Metal Hydride (NiMH) and Lead Acid.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"241 0 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121420569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Application of saturated core fault current limiters to interconnected distribution networks 饱和铁心故障限流器在互联配电网中的应用
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324847
S. Gunawardana, S. Perera, J. Moscrop
{"title":"Application of saturated core fault current limiters to interconnected distribution networks","authors":"S. Gunawardana, S. Perera, J. Moscrop","doi":"10.1109/AUPEC.2015.7324847","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324847","url":null,"abstract":"There is an increasing need for electricity utilities to limit fault levels in critical locations in power systems so that existing switchgear can continue to function as expected. This is particularly true in electrical distribution systems, where the increased penetration of renewable and decentralised generation is forcing the network to be highly interconnected in order to allow for higher integration capacity and reliable operation. Consequently, the short-circuit currents in distribution systems have increased significantly. In this background, application of fault current limiting devices is one of the solutions that is being considered by the Distribution Network Service Providers (DNSPs). A saturated core Fault Current Limiter (FCL) is one such device that can be used in existing and future electrical distribution systems to reduce the fault currents to a manageable level. This paper presents the potential performance of a saturated core FCL, in an interconnected 11kV test system, utilising a new comprehensive time-domain model to represent the FCL. PSCAD/EMTDC studies and numerical fault analysis are carried out to simulate the efficacy of an FCL when placed on a bus-tie of a looped circuit. The effect of the bus-tie FCL impedance on the network impedance and the subsequent fault current contributions is investigated. It is demonstrated that in a circuit with complex interconnections, suppression of fault currents need multiple FCLs in critical feeders.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"os-27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127771236","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A hybrid simulated annealing and perturb and observe method for maximum power point tracking in PV systems under partial shading conditions 部分遮阳条件下光伏系统最大功率点跟踪的模拟退火与扰动观测混合方法
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324803
S. Lyden, M. E. Haque
{"title":"A hybrid simulated annealing and perturb and observe method for maximum power point tracking in PV systems under partial shading conditions","authors":"S. Lyden, M. E. Haque","doi":"10.1109/AUPEC.2015.7324803","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324803","url":null,"abstract":"This paper presents a hybrid method for Maximum Power Point Tracking (MPPT) of a Photovoltaic (PV) system which experiences non-uniform environmental conditions or partial shading conditions. The hybrid method combines two simple techniques with complementary strengths in achieving Global MPPT. Simulated Annealing (SA) has only recently been applied to PV MPPT and is very effective at locating global maxima with limited implementation complexity. Perturb and Observe (P&O) is a very common technique which provides continuous tracking of the MPP in a simple and easy to implement manner. The P&O method is generally incapable of locating global maxima, and the SA based method is unable to perform continuous searching. By merging these techniques in a hybrid MPPT method consisting of a global searching stage and a local searching stage, the tracking performance is improved compared to what each technique could achieve independently. Simulation results are presented to demonstrate the effectiveness of the proposed hybrid technique.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130804462","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Trans-inverse (Tx−1) high step-up DC-DC converter 反反(Tx−1)高升压DC-DC变换器
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324797
Y. Siwakoti, F. Blaabjerg, P. Loh
{"title":"Trans-inverse (Tx−1) high step-up DC-DC converter","authors":"Y. Siwakoti, F. Blaabjerg, P. Loh","doi":"10.1109/AUPEC.2015.7324797","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324797","url":null,"abstract":"In this paper, a new magnetically coupled single-switch non-isolated dc-dc converter with a high voltage gain is proposed. The new topology utilizes a transformer to boost the output voltage. However, unlike other converter topologies with transformer or coupled magnetics, the voltage gain in the proposed topology is increased by reducing the turns ratio of the transformer. Hence the name Trans-inverse (Tx-1) is given to represent the inverse transformer principle of operation of the proposed converter. The new topology draws a continuous current from the source, which is required for many renewable sources. Further, the leakage energy of the transformer is recycled and transferred to the load using a passive regenerative snubber circuit. In addition, the new topology has dc-current-blocking capacitors, which avoids saturation in the transformer core. Simulation and experimental results have confirmed the validity of the proposed converter.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132630077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluation of the IEC 61000-3-11 procedures for the connection of multiple items of equipment 多设备连接的IEC 61000-3-11程序的评价
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324815
Maria Arechavaleta, M. Halpin
{"title":"Evaluation of the IEC 61000-3-11 procedures for the connection of multiple items of equipment","authors":"Maria Arechavaleta, M. Halpin","doi":"10.1109/AUPEC.2015.7324815","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324815","url":null,"abstract":"One way to manage voltage fluctuations in power systems is by limiting flicker emissions from individual items of equipment. The limits of voltage fluctuations produced by equipment having a rated input current less than 75 A intended to be connected to a public low-voltage (LV) distribution system are specified in IEC Standards 61000-3-3 and 61000-3-11. Evaluation procedures are included in 61000-3-11 which shall be applied if the equipment cannot meet the technical requirements and is therefore subject to conditional connection. In this case, the equipment has to be connected to a supply having an impedance lower than the reference impedance so that equipment emissions comply with the limits of the standards and manufacturers can declare the equipment to be compliant. Multiple formulas are provided in Clause 6 of IEC Standard 61000-3-11 for the determination of the required system impedance as a function of the reference impedance. One of the formulas supposedly addresses the connection of multiple items of equipment connected at the point of evaluation. The combined flicker effects of multiple items of equipment using the described methods in the standard are presented in this paper. Also, the cubic summation law, which is widely recognized by the industry and the standards, is used to evaluate flicker effects of multiple items. A comparison of these two methods for combining flicker effects is also presented. The results of using the formula provided by IEC Standard 61000-3-11 are shown to be over- or under-conservative depending on the specifics of the situation and the characteristics of the equipment involved.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133232399","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Assessing the effects of load models on MV network losses 评估负荷模型对中压网络损耗的影响
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324799
A. Ballanti, L. Ochoa
{"title":"Assessing the effects of load models on MV network losses","authors":"A. Ballanti, L. Ochoa","doi":"10.1109/AUPEC.2015.7324799","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324799","url":null,"abstract":"Network losses are often a key metric in evaluating the performance of planning and/or operational strategies. However, their assessment is traditionally carried out assuming a constant power load model that does not reflect the actual voltage-demand dependency, thus leading to inaccurate results. This work quantifies, in a real UK medium voltage (MV) network, the impact of three classic load models (constant power, current and impedance) on the quantification of energy and power network losses. A time-varying ZIP model designed for the UK residential demand is used as benchmark. Results indicate that the constant power load model, although underestimates the network losses throughout the year, outperforms the other models during summer (maximum error of 3% on power and 1.5% in energy). However, during winter the constant current model showed the best performance. The constant impedance model led to the highest errors and, consequently, should be in general avoided.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128819114","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Design and assembling of a permanent magnet synchronous machine with a Halbach magnet array for the application in an electric driven race car 用于电动赛车的哈尔巴赫磁体阵列永磁同步电机的设计与组装
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324808
E. Schmidt, C. Lechner
{"title":"Design and assembling of a permanent magnet synchronous machine with a Halbach magnet array for the application in an electric driven race car","authors":"E. Schmidt, C. Lechner","doi":"10.1109/AUPEC.2015.7324808","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324808","url":null,"abstract":"The paper discusses design and manufacturing of a prototype permanent magnet synchronous machine for an application in a fully electric driven racing car. Very high performance and low mass of these machines are achieved by using high performance FeCo stator sheets, a fractional slot stator winding build of tooth coils as well as a Halbach magnet array with a novel segmentation technology for reducing the eddy currents. The final design of these 40 kW / 30 Nm machines yields a total mass of only 3.95 kg. The operating range is up to 18000 rpm with a nominal speed of 12600 rpm.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123485391","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Nonlinear backstepping controller design for sharing active and reactive power in three-phase grid-connected photovoltaic systems 三相并网光伏系统有功无功分担非线性反步控制器设计
2015 Australasian Universities Power Engineering Conference (AUPEC) Pub Date : 2015-11-12 DOI: 10.1109/AUPEC.2015.7324866
T. K. Roy, M. A. Mahmud, M. J. Hossain, A. Oo
{"title":"Nonlinear backstepping controller design for sharing active and reactive power in three-phase grid-connected photovoltaic systems","authors":"T. K. Roy, M. A. Mahmud, M. J. Hossain, A. Oo","doi":"10.1109/AUPEC.2015.7324866","DOIUrl":"https://doi.org/10.1109/AUPEC.2015.7324866","url":null,"abstract":"In this paper, a nonlinear backstepping controller is designed for three-phase grid-connected solar photovoltaic (PV) systems to share active and reactive power. A cascaded control structure is considered for the purpose of sharing appropriate amount of power. In this cascaded control structure, the dc-link voltage controller is designed for balancing the power flow within the system and the current controller is designed to shape the grid current into a pure sinusoidal waveform. In order to balance the power flow, it is always essential to maintain a constant voltage across the dc-link capacitor for which an incremental conductance (IC) method is used in this paper. This approach also ensures the operation of solar PV arrays at the maximum power point (MPP) under rapidly changing atmospheric conditions. The proposed current controller is designed to guarantee the current injection into the grid in such a way that the system operates at a power factor other than unity which is essential for sharing active and reactive power. The performance of the proposed backstepping approach is verified on a three-phase grid-connected PV system under different atmospheric conditions. Simulation results show the effectiveness of the proposed control scheme in terms of achieving desired control objectives.","PeriodicalId":412677,"journal":{"name":"2015 Australasian Universities Power Engineering Conference (AUPEC)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121973756","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书