Proceedings of The 1st International Electronic Conference on Biosensors最新文献

筛选
英文 中文
Studying the reaction of peroxynitrite with myoglobin in meat extract samples using cobalt phthalocyanine-modified screen printed carbon electrodes and a flow injection analysis system 利用钴酞菁修饰的丝网印刷碳电极和流动注射分析系统研究肉提取物样品中过氧亚硝酸盐与肌红蛋白的反应
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-06 DOI: 10.3390/iecb2020-07310
I. Hosu, Diana Constantinescu-Aruxandei, F. Oancea, M. Doni
{"title":"Studying the reaction of peroxynitrite with myoglobin in meat extract samples using cobalt phthalocyanine-modified screen printed carbon electrodes and a flow injection analysis system","authors":"I. Hosu, Diana Constantinescu-Aruxandei, F. Oancea, M. Doni","doi":"10.3390/iecb2020-07310","DOIUrl":"https://doi.org/10.3390/iecb2020-07310","url":null,"abstract":"Reactive oxygen/nitrogen species (ROS/RNS) have a great impact on cellular response to stress, cell proliferation, cell death, cancer, aging, or male infertility. Additionally, in the food industry and for consumers as well, it is very important to monitor quality and freshness of raw meat. Different factors are a sign of meat alteration (e.g., discoloration, rancidity, alteration of flavor). One pathway of alteration is the scavenging activity of myoglobin towards RNS (such as peroxynitrite, PON). This paper presents the development of an electrochemical PON sensor using cobalt phthalocyanine (CoPc) as a simple, cost effective, highly thermally stable, biomimetic catalyst, and the application of this electrochemical screen-printed carbon electrode (SPCE)-based sensor to meat extract samples, using flow injection analysis (FIA). The reduction of peroxynitrite, mediated by CoPc, occurs at a very low potential (around 0.1 V vs. Ag/AgCl pseudoreference); as for higher potentials, the mechanism of mediation changes, and the electro-oxidation of PON is observed. The surface of the modified electrode was characterized using SEM, FTIR and Cyclic Voltametry. The interaction of PON with myoglobin was studied using both UV-Vis and chronoamperometry (at 0.1 V, using the FIA system). The calibration of the electrode was performed: Ired (nA) = 6.313·CPON (µM) + 17.469; (R² = 0.9938). The calculated LOD was equal to 2.37 µM and the linear range was 3–180 µM. The performance of the electrode can be further improved using a pre-treatment (electro-reduction of the CoPc deposited film, at −0.3 V, during 60s). This could help us monitor and quantify how much PON was decomposed and when meat extracts are spiked with different PON concentrations, in a highly selective, sensitive, and reproducible way.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"337 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129503140","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Deployment and comparison of a low-cost high-sensitivity concentration meters using micro-optical resonators 采用微光谐振器的低成本高灵敏度浓度计的研制与比较
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07091
Amir R. Ali, Maram Wael, R. Assal
{"title":"Deployment and comparison of a low-cost high-sensitivity concentration meters using micro-optical resonators","authors":"Amir R. Ali, Maram Wael, R. Assal","doi":"10.3390/iecb2020-07091","DOIUrl":"https://doi.org/10.3390/iecb2020-07091","url":null,"abstract":"Micro-optical resonators have been introduced as sensors in many applications for a wide number of variable types of stimuli due to their very high resolution, high sensitivity, and high-quality factor. In this paper, a novel micro-optical sensor was designed and tested as a concentration meter for chemical composition of a solution. The micro-optical resonator used is based on whispering gallery mode (WGM). This phenomenon appears when a tapered, single-mode laser carrying micro-optical fiber is evanescently coupled with a polymeric or silica micro-optical resonator. The presented sensor shows the change in concentration by experiencing a change in its morphology due to the varied viscosity of its environment. The variation of concentrations or fluid contents results in a change between the radii of the micro-optical resonator. With varied chemical composition and concentration in the tested sample varied infinitesimally small morphological changes are detected. The change in the resonators shape is read as a WGM shift in the resonance transmission spectrum, which is interpreted using a technique called cross-correlation, which compares the output across time to display the shift, which is later translated into distinct concentration levels. The proposed, exceptionally low-cost sensors were able to detect change at very high resolutions allowing better sensitivity along with wider range of variation. Experimental work for detection of ranges of concentrations of variable type of contaminants is presented.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115479113","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of optical and gravimetric methods for detection of chymotrypsin 光学法和重量法检测凝乳胰蛋白酶的比较
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07071
Ivan Piovarci, T. Hianik, I. Ivanov
{"title":"Comparison of optical and gravimetric methods for detection of chymotrypsin","authors":"Ivan Piovarci, T. Hianik, I. Ivanov","doi":"10.3390/iecb2020-07071","DOIUrl":"https://doi.org/10.3390/iecb2020-07071","url":null,"abstract":"Proteases play an important role in various biological as well as dairy industrial processes. In this work, we focused on chymotrypsin, which is an important protease in human digestion. Chymotrypsin also cleaves milk proteins, which makes it useful in the study of activity of milk proteases. In this work, we focused on detection of chymotrypsin using optical and gravimetric techniques, their peculiarities, and the limit of detection (LOD) (0.15 ± 0.005 nM and 0.64 ± 0.31 nM for optical and gravimetric methods, respectively). While the optical detection is easier to implement, the gravimetric method is more robust for sample preparation. Both methods could represent a novel assay for detection of chymotrypsin and other milk proteases.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116802461","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Comparison of leading biosensor technologies to measure endothelial adhesion, barrier properties and responses to cytokines in real-time 实时测量内皮粘附、屏障特性和细胞因子反应的领先生物传感器技术的比较
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07036
James J W Hucklesby, Akshata Anchan, S. O'Carroll, C. E. Angel, E. S. Graham
{"title":"Comparison of leading biosensor technologies to measure endothelial adhesion, barrier properties and responses to cytokines in real-time","authors":"James J W Hucklesby, Akshata Anchan, S. O'Carroll, C. E. Angel, E. S. Graham","doi":"10.3390/iecb2020-07036","DOIUrl":"https://doi.org/10.3390/iecb2020-07036","url":null,"abstract":"Electric Cell-substrate Impedance Sensing (ECIS), xCELLigence and cellZscope are commercially available instruments which are able to measure the impedance of cellular monolayers continuously and with high precision. The small currents used allow the label-free, real-time monitoring of the cells in a non-invasive manner. Despite the widespread use of these systems individually, direct comparisons between the systems have not been published. In order to compare the sensitivity of the instruments, the responses of the brain microvascular endothelial cell line hCMVEC to the inflammatory cytokines TNFα and IL1β were measured on all three instruments simultaneously. All three instruments showed transient decreases, followed by prolonged increases in impedance. Although xCELLigence could detect these changes, it was unable to determine which component of the barrier was affected. In contrast, ECIS and cellZscope were both able to attribute responses to particular barrier components, and ECIS had a higher sensitivity than cellZscope. Finally, as cellZscope uses Transwells, it allows access to the basolateral compartment, an important advantage of this technology. Furthermore, although xCELLigence readings are equivalent to ECIS, the reduced frequency range greatly limits interpretation. This work demonstrates that instruments must be carefully selected in order to ensure that they are appropriate for the experimental questions being asked.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123687594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
CATCHING THE SUGARS: ELECTROCHEMICAL APTASENSORS FOR THE DETECTION OF CANCER-RELATED GLYCOSYLATION CHANGES IN PROSTATE SPECIFIC ANTIGEN 捕获糖:用于检测前列腺特异性抗原中癌症相关糖基化变化的电化学适配体传感器
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07023
Ana Díaz-Fernández, R. Miranda‐Castro, P. Estrela, N. de-los-Santos-Álvarez, M. Lobo-Castañón
{"title":"CATCHING THE SUGARS: ELECTROCHEMICAL APTASENSORS FOR THE DETECTION OF CANCER-RELATED GLYCOSYLATION CHANGES IN PROSTATE SPECIFIC ANTIGEN","authors":"Ana Díaz-Fernández, R. Miranda‐Castro, P. Estrela, N. de-los-Santos-Álvarez, M. Lobo-Castañón","doi":"10.3390/iecb2020-07023","DOIUrl":"https://doi.org/10.3390/iecb2020-07023","url":null,"abstract":"Prostate-specific Antigen (PSA) is the biomarker that is used for prostate cancer (PCa) detection, although its lack of specificity results in a high rate of false-positives and many unnecessary biopsies. Therefore, there is a need for more specific cancer biomarkers for PCa. Recent studies have shown that the aberrant glycosylation of proteins is a common feature of the presence of cancer. In the case of prostate cancer, there are changes in core-fucose and sialic acids in the glycan structure of PSA. In this work, we describe two different strategies to direct the selection of aptamers toward the glycans of PSA. From these strategies, we identified two aptamers (PSA-1 and PSAG-1) that bind to the glycan structure of PSA with high affinity. Both aptamers were applied in the design of electrochemical aptasensors, in sandwich and direct formats, in order to detect the changes in the glycosylation of PSA. The sensors responded to different levels of PSA in serum, and they showed higher potential to discriminate clinically-meaningful PCa than the ELISA (Enzyme-linked immunosorbent assay) test used in hospitals (reducing the number of false positives), although validation on more samples is needed.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123862065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Realization of enhanced evanescent field long period fiber grating near turn around point for label-free immunosensing 用于无标记免疫传感的增强倏逝场长周期光纤光栅近转弯点的实现
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07063
T. K. Dey, S. Tombelli, P. Biswas, A. Giannetti, N. Basumallick, F. Baldini, S. Bandyopadhyay, C. Trono
{"title":"Realization of enhanced evanescent field long period fiber grating near turn around point for label-free immunosensing","authors":"T. K. Dey, S. Tombelli, P. Biswas, A. Giannetti, N. Basumallick, F. Baldini, S. Bandyopadhyay, C. Trono","doi":"10.3390/iecb2020-07063","DOIUrl":"https://doi.org/10.3390/iecb2020-07063","url":null,"abstract":"A Long period Fiber Grating (LPFG) with maximum enhancement of evanescent field has been designed and fabricated, along with theoretical modeling, by working near the turn-around point (TAP) of lowest order symmetric cladding mode (LP0,2 cladding mode). The LPFG was fabricated using point by point inscription technique and it was characterized in term of surrounding refractive index (SRI) within the range of 1.333 to 1.3335 using a thermostated flow-cell. This closed cell, made of poly(methyl methacrylate) (PMMA), was designed for better handling of the sensor, because during the fabrication process the diameter of the LPFG was reduced up to ~ 20 µm by chemical etching, for the maximum enhancement of evanescent field. The sensitivity of dual peak resonance of the LP0,2 cladding mode near TAP was measured and resulted to be ~ 8751 nm/SRIU with a resolution of the order of 10-5 RIU. The sensor was further used for the label-free immunosensing application by the implementation of Immunoglobulin G (IgG)/ anti- Immunoglobulin G (anti-IgG) bioassay on the grating region inside the thermostated closed flow cell and for real effectiveness along with the confirmation of the specificity, we perform the negative control test of the sensor using a complex matrix consisting of human serum.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114093817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Quenching of fluorescence caused by Graphene Oxide as an immunosensing platform in a microwell plate format 氧化石墨烯作为微孔板形式的免疫传感平台引起的荧光猝灭
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07017
Edwin J. Ortiz-Riaño, Mariana D. Ávila-Huerta, Diana L. Mancera-Zapata, E. Morales-Narváez
{"title":"Quenching of fluorescence caused by Graphene Oxide as an immunosensing platform in a microwell plate format","authors":"Edwin J. Ortiz-Riaño, Mariana D. Ávila-Huerta, Diana L. Mancera-Zapata, E. Morales-Narváez","doi":"10.3390/iecb2020-07017","DOIUrl":"https://doi.org/10.3390/iecb2020-07017","url":null,"abstract":": Immunoassays are, at present, an important tool for diagnostics, drug development, and environmental monitoring. However, most immunoassays involve procedures that require many elements for their development. We introduce a novel biosensing platform based on fluorescence quenching caused by graphene oxide (GO) for the detection of Human-IgG and Prostate-Specific Antigen (PSA). We employ a single antibody for the capture and detection processes, avoiding washing steps. FITC fluorophore was conjugated with antibodies for H-IgG detection, whereas quantum dots were conjugated with antibodies for PSA detection. The simple biosensing platform consists of covering a 96-well microplate (with a polystyrene bottom) with GO. The graphene oxide adhesion is possible by way of electrostatic interactions between the plate surface modified with amino groups (positively charged) and the graphene oxide (negatively charged). This proposal showed an excellent response for the detection of Human-IgG, with acceptable precision (from 0.27% to 5%). The limit of detection reached for H-IgG was 3.35 ng m L (cid:2879)(cid:2869) . In the same manner, for PSA detection, the limit of detection reached was 0.02 ng m L (cid:2879)(cid:2869) and the precision range was from 0.7% to 15.2%. Furthermore, this biosensing platform was demonstrated to operate with real samples of human urine doped with different concentrations of prostate-specific antigen.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126585507","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Giving New Uses to Glucose Meters: Detection of Prostate Cancer 赋予血糖仪新的用途:前列腺癌的检测
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07024
Clara Abardía-Serrano, R. Miranda‐Castro, N. de-los-Santos-Álvarez, M. Lobo-Castañón
{"title":"Giving New Uses to Glucose Meters: Detection of Prostate Cancer","authors":"Clara Abardía-Serrano, R. Miranda‐Castro, N. de-los-Santos-Álvarez, M. Lobo-Castañón","doi":"10.3390/iecb2020-07024","DOIUrl":"https://doi.org/10.3390/iecb2020-07024","url":null,"abstract":"A sandwich genoassay for the detection of PCA3, a nucleic acid biomarker overexpressed in the urine of prostate cancer patients, has been developed by using the enzyme alkaline phosphatase (ALP) as a tracer of the hybrid generated onto the surface of magnetic particles. ALP converts D-glucose-1-phosphate into D-glucose, which is quantified with a personal glucose meter. The resulting methodology allows the reliable detection of PCA3 at low picomolar levels, thus fostering massive screening of prostate cancer.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122190283","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Real-time pathogen determination by optical biosensing based on graphene oxide 基于氧化石墨烯的光学生物传感实时病原体检测
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07016
Mariana D. Ávila-Huerta, Edwin J. Ortiz-Riaño, Diana L. Mancera-Zapata, E. Morales-Narváez
{"title":"Real-time pathogen determination by optical biosensing based on graphene oxide","authors":"Mariana D. Ávila-Huerta, Edwin J. Ortiz-Riaño, Diana L. Mancera-Zapata, E. Morales-Narváez","doi":"10.3390/iecb2020-07016","DOIUrl":"https://doi.org/10.3390/iecb2020-07016","url":null,"abstract":"Pathogenic bacterial contamination in food is a public health concern. It represents a health and safety consumer risk that could cause several diseases and even death. Currently, the food industry uses culture-based assays to determine the presence of pathogens as a gold standard method. Although this method is highly accurate, it is often time-consuming and expensive. In this regard, the development of biosensing platforms results as an alternative for the reduction of time and cost of pathogenic bacteria detection in food. In this work, we report the development of a single-step bacterial detection platform based on graphene oxide. Non-radiative energy transfer between graphene oxide coated microplates (GOMs) and photoluminescence bioprobes (PLBs) is presented in absence of the target analyte, but in presence of analyte, PLBs exhibit strong photoluminescence due to the distance between GOMs and PLBs. These PLBs are based on quantum dot (Qds)-antibody (Ab) complexes, thereby resulting as a biorecognition and interrogation element. Escherichia coli was used as model analyte. In optimal conditions, the bacterial detection platform reached a limit of detection around 2 CFU mL−1 in 30 min, enabling a fast and sensitive alternative for bacterial detection. The biosensing platform was also used to test food industry samples achieving a qualitative response, that allows determining the presence of E. coli during the first 30 min of the assay. This biosensing strategy potentially offers a low-cost and quick option for the food industry to assure the quality of the product and consumer safety.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123829161","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Label-free peptide-based biosensor for express detection of protein markers of acute cardiovascular conditions in biological fluids 基于无标记肽的生物传感器,用于生物液体中急性心血管疾病蛋白标志物的表达检测
Proceedings of The 1st International Electronic Conference on Biosensors Pub Date : 2020-11-02 DOI: 10.3390/iecb2020-07066
N. Sitkov, T. Zimina, V. Karasev, Olesya A. Naretskaya, Margarita I. Kiseleva
{"title":"Label-free peptide-based biosensor for express detection of protein markers of acute cardiovascular conditions in biological fluids","authors":"N. Sitkov, T. Zimina, V. Karasev, Olesya A. Naretskaya, Margarita I. Kiseleva","doi":"10.3390/iecb2020-07066","DOIUrl":"https://doi.org/10.3390/iecb2020-07066","url":null,"abstract":"Acute cardiovascular conditions require prompt assistance, which depends on a timely and accurate diagnosis. This could be achieved by using biosensor systems based on peptide aptamers capable of selectively binding protein markers of diseases. In this work, a label-free biosensor system based on fluorometric registration of the formation of a “peptide aptamer—target protein” complex is considered. It comprises a microfluidic subsystem integrated with arrays of sites with immobilized peptide aptamers, coupled with an optical detection system. The clinical sample of the whole blood is loaded into the inlet basin, where the cells are separated and plasma flows into the microfluidic channel for analysis. Peptide aptamers were created using the molecular complement search technique based on the search for systems of conjugated ion-hydrogen bonds in the three-dimensional structures of target proteins. The technology for manufacturing a microfluidic chip is a combination of thick-film and photolithography technologies based on the SU-8 photoresist, for which the relief and surface morphology have been studied. The composition of the biochip layers is selected in such a way that ultraviolet light with a wavelength of 280 nm passes through an inlet window, excites fluorescence inside the channel, which passes through the glass window, which absorbs UV-light. This wavelength accounts for the maximum absorption of aromatic amino acids—tyrosine and tryptophan. In this case, one of the last layers is a luminophore layer for re-emission of protein fluorescence as a visible light. The reading platform includes a 280 nm LED, a video sensor, 3D-printed PLA tooling, and software for processing and analyzing the received signal.","PeriodicalId":407547,"journal":{"name":"Proceedings of The 1st International Electronic Conference on Biosensors","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122488740","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书