{"title":"Impact of circuit breaker failure modes on the reliability of the gold book standard network","authors":"J. Dong, D. Koval, M. Zuo","doi":"10.1109/ICPS.2004.1314988","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314988","url":null,"abstract":"The failure modes of circuit breakers have a significant impact on individual load point reliability levels of industrial power systems. This paper presents and discusses the significant variations in the frequency and duration of load point interruptions in the IEEE Gold Book Standard Network Configuration due to changes in circuit breaker failure modes. The reliability analysis was based on the zonebranch reliability methodology [1,7]. Five case studies with different percentages of open and short-circuit failure modes of circuit breakers and fuses will be presented and discussed in detail.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129242840","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Simplified arc-fault model: the gearing pace model","authors":"G. Parise, L. Martirano, T. Gammon","doi":"10.1109/ICPS.2004.1314994","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314994","url":null,"abstract":"The paper refers to recently published arc models defining the arc voltage and the arc current. It is generally recognized that the arc-fault impedance is a resistance and the arc current contains harmonics; therefore, the resulting fault impedance has a larger magnitude and a power factor much closer to unity than a short circuit in the bolted-fault circuit. To simplify past approaches of arc modeling, this work suggests considering the arc current as the fundamental harmonic. The arc voltage is modeled as a RMS voltage, Va, across a pure resistance; in this paper, the RMS arc voltage is defined as a function of gap width and bolted-fault current. The arc resistance and phase angle of the arc-fault circuit can be determined when the RMS arc voltage and the bolted-fault circuit impedance values are known. The behavior of the arc current is obtainable as an extension of bolted short-circuit analysis. Like a soldier has to gear the pace if by chance he introduces himself in the marching troupe, so he solves jumping or rubbing the feet, analogously the fault current does the same. With this approach, the behavior of the arc fault can be easily understood and the arc fault parameters such as conduction angle, peak value, and decreasing-to-zero value can be easily evaluated.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129422183","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Chompoo-Inwai, W. Tangsrianugul, V. Pornpojratanakul, S. Banjongjit
{"title":"Development of an electronics ballast for a 250-watt high intensity discharge lamp","authors":"C. Chompoo-Inwai, W. Tangsrianugul, V. Pornpojratanakul, S. Banjongjit","doi":"10.1109/ICPS.2004.1314979","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314979","url":null,"abstract":"The main objective of this paper is to purpose the newly developed prototype of electronics ballast used for 250 watt high pressure sodium (HPS) lamp. In this paper, concept designs, circuit designs, and the implementation of the 250 watt prototype-ballast are presented. Test result shows that the newly developed model provides not only lower loss compares to the traditional core-coil ballast, but also give the higher system efficiency. Moreover, the overall system power factor is above 0.85 lagging with the expectation of percentage of total harmonics distortion less than 30 percent. All test procedures, and conditions are applied to employ with 250 high pressure metal halide (HPM) lamp as well.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116770948","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimization of dc feeder rate of rise overcurrent protection settings using delta i cumulative distribution","authors":"M. Reis","doi":"10.1109/ICPS.2004.1314983","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314983","url":null,"abstract":"A novel approach for optimizing the protection settings of DC rate-of-rise overcurrent relays is presented in this paper. It is based on a program developed in Matlab that analyses digitally recorded feeder current data and provides a graphical cumulative distribution profile of the step current increase (Delta I) versus slope (di/dt) characteristics. It was successfully used to enhance the overcurrent protection sensitivity of an existing traction power distribution system without leading to nuisance tripping. The rate-of-rise protection optimization involves the broadening of the DC short circuit detection range while preserving good discrimination between fault and normal rolling stock acceleration currents.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115724573","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Protective relaying considerations for standby generation systems","authors":"T. Coyle","doi":"10.1109/ICPS.2004.1314984","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314984","url":null,"abstract":"Increasingly, engine-driven generators installed primarily to serve as a standby power source during a utility outage are being used for peak shaving or load control through continuous parallel operation or closed-transition transfer with the electric utility grid. Higher capacity requirements of mission-critical standby systems, such as those in hospitals and data centers, have led to the parallel operation of large numbers of generators on a common standby bus. These applications require more sophisticated electrical protection than traditional standby operation, both to satisfy utility interconnection requirements and to protect the generator(s) from abnormal system conditions. A great deal has already been published on the topic of generator and utility intertie protection, most of it directed primarily at turbine-driven units and utility-scale installations. This paper will discuss the protective relaying of generators and utility interconnections from the perspective of standby application, and identify unique considerations for selecting and setting some of the common protective relay elements, considering issues not fully addressed in the traditional references. Topics covered include accommodating loading transients, preservation of the standby mission, and protection of low voltage generators.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123450829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Improved method for arc flash hazard analysis","authors":"R. Wilkins, M. Allison, M. Lang","doi":"10.1109/ICPS.2004.1314982","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314982","url":null,"abstract":"Conventional arc flash hazard calculators use simple formulae to calculate the flash protection boundary and the incident energy density, but these methods do not represent the effects of the power supply system correctly. A new method is described which models the transient response of a 3-phase power system and its interaction with an arcing fault. The operation of current-limiting fuses in the time domain, and the focusing effect of the equipment enclosure are also considered.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125491998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analyzing the IEEE 1584-2002 data set and developing simple incident energy equations for low-voltage systems (< 1 kV)","authors":"T. Gammon, J. Matthews","doi":"10.1109/ICPS.2004.1314991","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314991","url":null,"abstract":"The release of IEEE Standard 1584-2002, IEEE Guide for Performing Arc-Flash Hazard Calculations, is formal recognition of the danger of arcing faults in electrical systems. The standard includes an extensive data set used for developing the 1584-2002 arc-flash calculator which predicts three-phase arc current and incident energy for appropriate selection of overcurrent protective devices and personal protective equipment, respectively. As an additional benefit, the published data set can further enhance the understanding of the electrical characteristics of arcing faults in industrial power systems. The 1584 data set has been both quantitatively and qualitatively analyzed to assess the relationships between arc current, arc voltage, system voltage, arc power, and incident energy, as well as other variables such as gap widths and the effect of equipment enclosures. Simple relationships for estimating three-phase arc current, arc power, and incident energy on low-voltage (< 1 kV) systems are presented.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123484462","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Mozina, M. Young, B. Bailey, D. Baker, G. Dalke, B. Duncan, J. Fischer, D. Love, N. Nichols, C. Normand, L. Padden, A. Pierce, P. Pillai, L. Powell, T. Stringer
{"title":"Commissioning and maintenance testing of multifunction digital relays","authors":"C. Mozina, M. Young, B. Bailey, D. Baker, G. Dalke, B. Duncan, J. Fischer, D. Love, N. Nichols, C. Normand, L. Padden, A. Pierce, P. Pillai, L. Powell, T. Stringer","doi":"10.1109/ICPS.2004.1314986","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314986","url":null,"abstract":"Protective relay technology over the past twenty-five years has evolved from single-function electromechanical (E-M) relays to static (electronic) relays and finally to digital multifunction relays. A significant number of these multifunction digital relays are being installed on medium voltage electric power systems within industrial and commercial facilities. As was required in earlier E-M and static relay technologies, digital relays also require commissioning and relay setting verification. This paper discusses the unique challenges the user faces in testing and commissioning digital multifunction relays. It also explores the impact on maintenance testing of self-diagnostics, the digital relay¿s internal capability to check itself for failures.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123899072","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Creating electrical hazard awareness with communication using msds and labeling","authors":"M. Capelli‐Schellpfeffer","doi":"10.1109/ICPS.2004.1314995","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314995","url":null,"abstract":"There is credible data to support the assertion that power frequency electrical energy exposure is potentially life-threatening. While given little thought in many occupational settings, working on, near, or with electrical energy can transition from harmless to harmful activity across ultra-short time and spatial dimensions. Furthermore, the hazards associated with electricity use are uniquely challenging. Because electrical energy¿s presence saturates daily task performance in a silent, odorless, and invisible manner, people are routinely cognitively desensitized to the physical potency of electrical energy¿s fundamental electrothermal-chemical nature. To advance personal and public safety, employers can create electrical hazard awareness with communication using material safety data sheet (MSDS) and labeling in familiar formats adapted from training for chemical safety.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117101498","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Stochastic dynamic generation models in electricity markets","authors":"J. Wu, J. Long, J.X. Wang","doi":"10.1109/ICPS.2004.1314980","DOIUrl":"https://doi.org/10.1109/ICPS.2004.1314980","url":null,"abstract":"Optimization models and algorithms for dynamic generation with multiple services in electricity markets are presented in this paper. One of optimal model aims at determining the total quantities of generation for three services such as real power, reactive power and reserve as a whole, another model is used for determining the generation quantities of each generating unit for three services at each hour in the dayahead markets. Some factor such as rated power factor, stochastic load, holding costs, short costs, start up costs and shut down costs are taken into consideration, and the proposed models are solved with the help of genetic programming. The results of a numerical example show that the quantities put into energy market, reactive power market and reserve market depend not only on the production costs, holding costs and short costs but also on stochastic load demands and the clear prices of three markets. Simulation analysis is accomplished with 10 units in Matlab software, and the results of the simulation are satisfactory.","PeriodicalId":407544,"journal":{"name":"Conference, 2004 IEEE Industrial and Commercial Power Systems Technical","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126585125","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}