{"title":"Reliability of poles in NESC grade C construction","authors":"H. Dagher","doi":"10.1109/REPCON.2001.949521","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949521","url":null,"abstract":"The reliabilities of steel and wood poles designed according to the 1997 National Electric Safety Code provisions for Grade C construction were evaluated. It was found that the reliability of steel poles may be significantly higher than that of wood poles. Reasons for the discrepancy relate to the historical development of the deterministic design approach used in the National Electric Safety Code specifications. For correction of this discrepancy, fundamental principles of structural reliability were used to develop modified load factors and strength factors applicable to all materials under Grade C construction. A load factor of 1.75 is proposed for all materials, and a table of strength factors is proposed. The strength factors are a function both of the coefficient of variation of the pole strength and the lower exclusion limit corresponding to the nominal design strength value. As an interim measure, it is proposed that the modified load and strength factors for Grade C construction be allowed as an alternative approach in the National Electric Safety Code. Ultimately a complete rewriting of the National and-resistance-factor-design approach will be necessary to guarantee consistent safety levels across all materials and structure types.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114884719","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Written-Pole/sup (R)/ motor eliminates water hammer on irrigation and municipal water systems","authors":"R. Morash, R. Knick","doi":"10.1109/REPCON.2001.949515","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949515","url":null,"abstract":"Flywheel energy is stored in the high inertia rotor of a special Written-Pole/sup (R)/ motor. This Power-Ride/sup (R)/ motor is made inside-out, with the outside rotor spinning around the wound stator that is inside. Using this motor to drive a water pump causes slow rates of acceleration and deceleration. This leads to slow changes in flow rates of the water being pumped. Water hammer is caused by rapid changes in flow in water pipes. The use of this motor reduces the probability of water hammer. Other advantages are also described including very low start current, reduced line flicker, high efficiency and unity power factor. The paper discusses water hammer, Written-Pole motor technology, and presents case histories.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126591677","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Reconductoring power lines- an example exercise in conductor selection","authors":"G. C. Baker","doi":"10.1109/REPCON.2001.949524","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949524","url":null,"abstract":"There are numerous factors that must be considered when upgrading the current carrying capacity of an existing transmission or distribution line. The selection of the replacement conductor may not be as straightforward and simple as changing to a larger conductor size. A more viable solution may be to evaluate the ACSS conductor design. This paper provides a brief explanation of what the ACSS (aluminum conductor, steel supported) product is, and then provides an example study that was used to provide reconductoring options to upgrade the current carrying capacity of transmission line circuits.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131966212","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electric deregulation impacts on metering, billing and customer information systems","authors":"R. McClanahan","doi":"10.1109/REPCON.2001.949509","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949509","url":null,"abstract":"Electric industry deregulation is approaching in many states, bringing with it enormous changes in the way that distribution utilities handle information within their customer information, metering and billing systems. Traditional utility metering and billing processes could largely become a thing of the past when such concepts as retail open access, 3/sup rd/ party metering and competitive billing services become the norm. In addition, distribution utilities will be required to develop electronic data interchange capabilities with many other entities that did not exist prior to the advent of retail competition. This paper examines a number of business processes in the retail electric market and explores the information that will be required to implement those processes.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130406856","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Common interfaces for enterprise integration-experience with NRECA's MultiSpeak/sup TM/ specification","authors":"G. McNaughton, M. E. Gordon","doi":"10.1109/REPCON.2001.949520","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949520","url":null,"abstract":"Enterprise integration has been an elusive goal for utilities for many years. Often the integration that has been achieved has relied on custom development of interfaces at each utility. This approach has been time consuming and expensive even when successful. Unfortunately, small utilities, such as most electric distribution cooperatives, do not have the information systems staff resources to attack integration in this manner; rather they often rely on vendors to provide suites of interoperable software. As a result, either their choices of software are limited or they must pay vendors to create and maintain custom software interfaces. In recent years, vendors serving this market have devoted a significant part of their development resources to writing the required interfaces, often to the exclusion of enhancing their core products. Thus co-ops and vendors have a shared need and significant incentive to address the lack of a standard means of software integration. The MultiSpeak Initiative is a collaborative effort of about forty vendors sponsored by the Cooperative Research Network of the National Rural Electric Cooperative Association. The Initiative has developed a specification for common data interfaces among backoffice applications widely applied at distribution cooperatives. This paper discusses the development of that specification. The purposes for the effort, the multi-vendor, collaborative approach taken during its development, the successes achieved as a result of its completion, and the promise for the future are presented.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125921338","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Operating conflicts for distributed generation on distribution systems","authors":"R. Dugan, T. Mcdermott","doi":"10.1109/REPCON.2001.949511","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949511","url":null,"abstract":"Distribution systems have been designed to optimize the delivery of power in one direction. The installation of distributed generation (DG) in significant capacity will result in some conflicts with the operation of the system. A selected set of conflicts is described. One conflict might result in changes to overcurrent device timing and reach that degrade reliability and power quality for other customers on the feeder. Interconnection requirements can increase the risk of equipment damage due to ferroresonant overvoltages. Transformer connections for DG involve a tradeoff between harmonic current injections, the risk of overvoltages, protective device coordination, and transformer life. The paper also addresses voltage regulation issues that often arise from the application of DG on distribution systems.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114857548","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Advanced transformer paralleling","authors":"E. T. Jauch","doi":"10.1109/REPCON.2001.949517","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949517","url":null,"abstract":"This paper introduces an innovative method for providing control of paralleled load tap changer power transformers, and compares and evaluates other paralleling methods presently in use. The new paralleling method provides optimal operation for substation configurations that are becoming more prevalent in present-day power systems; these configurations have never been addressed by other paralleling methods. The comparison includes the following methods: negative reactance; master/follower; power factor; and circulating current.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122329497","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Computer applications in the electrical utility industry","authors":"T. Pittser","doi":"10.1109/REPCON.2001.949518","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949518","url":null,"abstract":"Recently, a line has emerged: on one side computer applications working productively for electric utilities; and on the other side computer applications posing a burden for the utility. Setting clear objectives and research will assure a utility of being on the productive side of the line. Computer systems that work well for one utility may not work well for another. Electric utilities are different in many ways with the result that software applications should be examined for applicability to a given systems operation.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127761374","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of wood pole strength-Polux/sup (R)/ a new nondestructive inspection method","authors":"Edward Ezer","doi":"10.1109/REPCON.2001.949523","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949523","url":null,"abstract":"Wood pole structures make up a large part of utility transmission and distribution networks. Loading on in-service poles is increasing sometimes beyond design limits due to additional attachments of fiber optics and cable TV and more violent weather. The paper describes a new technology, Polux, that can provide asset managers with reliable objective pole strength data to support maintenance and capital expenditure decisions. The instrument integrates the groundline measurement of fiber strength and moisture content of a pole with six other parameters: species, knots, circumference, height, age and mechanical damage to calculate the moment of rupture (MOR) at groundline. This MOR compares directly with the ANSI value to derive a percentage loss of strength from new. Correlation of this technology with actual pole breaking tests is better than r=0.8.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"62 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114024536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Selection of wood pole alternatives by means of present-worth analysis","authors":"M. Shaw, D. Snyder","doi":"10.1109/REPCON.2001.949522","DOIUrl":"https://doi.org/10.1109/REPCON.2001.949522","url":null,"abstract":"In evaluating alternatives in the design of transmission facilities, first cost alone is not always the true cost of the project. Using the present-worth method to determine the cost of the project over the life of the facilities represents the total cost of constructing and maintaining the facilities. Present-worth analysis was also used in determing whether it was more economical to completely rebuild the line or to continue maintenance on the existing line. In this example the analysis showed that a completely new line using larger conductor and steel poles was a more economical design over the estimated 50-year life of the line.","PeriodicalId":397929,"journal":{"name":"2001 Rural Electric Power Conference. Papers Presented at the 45th Annual Conference (Cat. No.01CH37214)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114335201","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}