{"title":"CFD Analysis of Molten Solder Flow Behavior and Bridging Mechanism During Solder Bump Formation","authors":"Risa Miyazawa, K. Okamoto, H. Mori","doi":"10.1115/ipack2019-6395","DOIUrl":"https://doi.org/10.1115/ipack2019-6395","url":null,"abstract":"\u0000 Technology of fine pitch interconnect with lead-free solder joint has been developed to enhance the performance of flip-chip high density packages. This study presents an investigation of solder bump forming behavior by means of CFD simulation analysis. The flow motion of molten solder is analyzed with 3D model we developed, and the simulation result is validated with the experiment. Moreover, the investigation of factors affecting solder bridging across adjacent pads is also performed. It is revealed that wettability between liquid solder and organic insulator, which is represented as contact angle in the calculation has large effect on the solder bridging phenomena. The simulation result suggests that worsening the wettability of the insulator can reduce the occurrence of bridging.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130543892","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Uschas Chowdhury, Hendrix Walter Mark, T. Craft, James Willis Frank, Ankita Sutaria, D. Agonafer
{"title":"Optimal Design and Modeling of Server Cabinets With In-Row Coolers and Air Conditioning Units in a Modular Data Center","authors":"Uschas Chowdhury, Hendrix Walter Mark, T. Craft, James Willis Frank, Ankita Sutaria, D. Agonafer","doi":"10.1115/ipack2019-6522","DOIUrl":"https://doi.org/10.1115/ipack2019-6522","url":null,"abstract":"\u0000 In a data center, electronic equipment such as server and switches dissipate heat and the corresponding cooling systems contribute to typically 25–35% of total energy consumption. The heat load continues to increase as there is a greater need for miniaturization and convergence. In 2014, data centers in the U.S. consumed an estimated 70 billion kWh, representing about 1.8% of total U.S. electricity consumption. Based on current trend estimates, U.S. data centers are projected to consume approximately 73 billion kWh in 2020 [1]. Many research and strategies are adopted to minimize energy cost. The recommended dry bulb temperature for long-term operation and reliability for air cooling is between 18–27°C and the largest allowable inlet temperature range to operate at is between 5°C and 45°C with American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) enabling much broader allowable zones) [2]. But understanding a proper cooling system is very important especially for thermal management of IT equipment with high heat loads such as 1U or 2U multi-core, high-end servers and blade servers which provide more computing per watt. Many problems like high inlet temperature due to the mixing of hot air with cold air, local hot spots, lower system reliability, increased failure, and downtime may occur. Among many other approaches to managing high-density racks, in-row coolers are used in between racks to provide cold air and minimize local hot spots. This paper describes a computational study being performed by applying in-row coolers for different rack power configuration with and without aisle containment. The power, as well as the number of racks, are varied to study the effect of raised inlet temperature for the IT equipment in a Computational Fluid Dynamics (CFD) model developed in 6SigmaRoom with the help of built-in library items. A comparative analysis is also performed for a typical small-sized non-raised facility to investigate the efficacy and limitations of in-row coolers in thermal management of IT equipment with variation in rack heat load and containment. Several other aspects like a parametric study of variable opening areas of duct between racks and in-row coolers, the variation of operating flow rate and failure scenarios are also studied to find proper flow distribution, uniformity of outlet temperature and predict better performance, energy savings and reliability. The results are presented for general guidance for flexible and quick installation and safe operation of in-row coolers to improve thermal efficiency.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114080568","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Lall, Kartik Goyal, Nakul Kothari, Benjamin J. Leever, Scott Miller
{"title":"Effect of Process Parameters on Aerosol Jet Printing of Multi-Layer Circuitry","authors":"P. Lall, Kartik Goyal, Nakul Kothari, Benjamin J. Leever, Scott Miller","doi":"10.1115/ipack2019-6574","DOIUrl":"https://doi.org/10.1115/ipack2019-6574","url":null,"abstract":"\u0000 Printing technologies such as Aerosol Jet provides the freedom of miniaturizing interconnects and producing fine pitch components. Aerosol Jet, a direct printing technique replaces the traditional steps of manufacturing a printed circuit board such as lithography or etching, which are quite expensive, and further allowing the circuits to be fabricated onto all kinds of substrates. Wide impact areas range from healthcare to wearables to future automotive applications. The aerosol jet printer from Optomec utilized in this study, consists of two types of atomizers depending on ink viscosity. One is Ultrasonic Atomizer which supports ink with viscosity range of 1–5cP, and another is Pneumatic Atomizer with large range of suitable viscosity 1–1000cP. This paper focuses on utilizing the aerosol jet printing using both the atomizers to develop process parameters to be able to successfully print bi-material, multi-layer circuitry. The insulating material between two conductive lines used in the paper is of very high viscosity of 350cP, suitable for Pneumatic atomizer and Silver Nano-particle ink with the viscosity suitable for Ultrasonic atomizer as a conductive ink. A statistical modeling approach is presented to predict the attributes such as micro-via diameter before starting the print process, enabling us to pre-adjust the dimensions in CAD for the desired output. Process parameters to obtain a fine print with good electrical properties and better dimensional accuracy are developed. Importance of pre-cleaning the substrate is discussed, in addition to the printing process efficiency gauged as a function of process capability index and process capability ratio.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"35 23","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120991275","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Piezoresistive Theory for 4H Silicon Carbide Stress Sensors on Four-Degree Off-Axis Wafers","authors":"Jun Chen, R. Jaeger, J. Suhling","doi":"10.1115/ipack2019-6461","DOIUrl":"https://doi.org/10.1115/ipack2019-6461","url":null,"abstract":"\u0000 Piezoresistive stress sensors have been shown to be a powerful tool for experimental evaluation of die stress distributions. Silicon Carbide (SiC) wide bandgap semiconductors are promising materials for development of high temperature power electronics. In the past, the analysis and design of stress sensors on silicon carbide have assumed that the wafer surface is aligned with the crystallographic axes. However, 4H silicon carbide wafers are produced with a four-degree off-axis cut to ensure high-quality homoepitaxial growth, so that the tilted wafer surface does not perfectly coincide with the fundamental crystallographic axis. Thus, the prior “on-axis” theory is an approximation, and errors in piezoresistive theory caused by such tilted wafer plane need to be discussed. These errors can affect both the results from calibration experiments as well as the stresses extracted during application of sensor rosettes.\u0000 This paper discusses the theory and extraction of piezoresistive coefficients for 4H-SiC silicon carbide materials in the presence of off-axis starting wafers. Coordinate transformations for the piezoresistive coefficients are reviewed, the required direction cosines between the new rotated axes and the ideal axes are discussed, and the 6 × 6 matrix of piezoresistive coefficients (π-matrix) for the on-axis and off-axis cases are calculated. Many of the elements of the ideal on-axis π-matrixes are zero. In contrast, the off-axis is completely filled with non-zero values indicating additional coupling, particularly among the shear coefficients. Examples of the overall impact of these new terms on calibration and stress measurement are discussed.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117071617","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jimil M. Shah, R. Dandamudi, Chinmay Bhatt, Pranavi Rachamreddy, Pratik V. Bansode, D. Agonafer
{"title":"CFD Analysis of Thermal Shadowing and Optimization of Heatsinks in 3rd Generation Open Compute Server for Single-Phase Immersion Cooling","authors":"Jimil M. Shah, R. Dandamudi, Chinmay Bhatt, Pranavi Rachamreddy, Pratik V. Bansode, D. Agonafer","doi":"10.1115/ipack2019-6600","DOIUrl":"https://doi.org/10.1115/ipack2019-6600","url":null,"abstract":"\u0000 In today’s networking world, utilization of servers and data centers has been increasing significantly. Increasing demand of processing and storage of data causes a corresponding increase in power density of servers. The data center energy efficiency largely depends on thermal management of servers. Currently, air cooling is the most widely used thermal management technology in data centers. However, air cooling has started to reach its limits due to high-powered processors. To overcome these limitations of air cooling in data centers, liquid immersion cooling methods using different dielectric fluids can be a viable option. Thermal shadowing is an effect in which temperature of a cooling medium increases by carrying heat from one source and results in decreasing its heat carrying capacity due to reduction in the temperature difference between the maximum junction temperature of successive heat sink and incoming fluid. Thermal Shadowing is a challenge for both air and low velocity oil flow cooling. In this study, the impact of thermal shadowing in a third-generation open compute server using different dielectric fluids is compared. The heat sink is a critical part for cooling effectiveness at server level. This work also provides an efficient range of heat sinks with computational modelling of third generation open compute server. Optimization of heat sink can allow to cool high-power density servers effectively for single-phase immersion cooling applications. A parametric study is conducted, and significant savings in the volume of a heat sink have been reported.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"os-53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127789677","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Thermoreflectance Imaging of Electromigration in Aluminum Interconnects at Different Ambient Temperatures","authors":"S. Alajlouni, K. Maize, P. Bermel, A. Shakouri","doi":"10.1115/ipack2019-6413","DOIUrl":"https://doi.org/10.1115/ipack2019-6413","url":null,"abstract":"\u0000 Electromigration (EM) is the process of displacing atoms in metals due to current flow leading to interconnect failures in electronic circuits. As electronics feature sizes continue to shrink, EM is becoming an increasingly serious reliability concern. EM, in aluminum (Al) interconnects, has been studied previously, but typically on the device level using Black’s law [1], without emphasis on the localized heating and defect generation around the failure site. To better understand the local EM process, thermoreflectance (TR) thermal imaging technique is used to obtain temperature profiles with submicron resolution [2]. We show that a simple lifetime prediction using Black’s law is not possible for a micro Al wire having a patterned constriction. The wire fails at two distinct failure locations depending on the level of current excitation. Moreover, the lifetime dependence on ambient temperature was studied. Each failure location had its own extracted activation energy. Our findings suggest that Black’s law may be extended to local features. They also show the potential for the design of local features in extending the lifetime of metallic interconnects. In summary, the temperature profile with submicron spatial resolution offers a unique opportunity to better understand the different mechanisms contributing to EM failures which can be used to design highly reliable interconnects.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125874020","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Jung, Hyoungsoon Lee, Chirag R. Kharangate, Feng Zhou, M. Asheghi, E. Dede, K. Goodson
{"title":"Experimental Investigation of Single-Phase Cooling in Embedded Microchannels: 3D Manifold Heat Exchanger With R-245fa","authors":"K. Jung, Hyoungsoon Lee, Chirag R. Kharangate, Feng Zhou, M. Asheghi, E. Dede, K. Goodson","doi":"10.1115/ipack2019-6400","DOIUrl":"https://doi.org/10.1115/ipack2019-6400","url":null,"abstract":"\u0000 High performance and economically viable thermal cooling solutions must be developed to reduce weight and volume, allowing for a wide-spread utilization of hybrid electric vehicles. The traditional embedded microchannel cooling heat sinks suffer from high pressure drop due to small channel dimensions and long flow paths in 2D-plane. Utilizing direct “embedded cooling” strategy in combination with top access 3D-manifold strategy reduces the pressure drop by nearly an order of magnitude. In addition, it provides more temperature uniformity across large area chips and it is less prone to flow instability in two-phase boiling heat transfer. Here, we present the experimental results for single-phase thermofluidic performance of an embedded silicon microchannel cold-plate bonded to a 3D manifold for heat fluxes up to 300 W/cm2 using single-phase R-245fa. The heat exchanger consists of a 52 mm2 heated area with 25 parallel 75 × 150 μm2 microchannels, where the fluid is distributed by a 3D-manifold with 4 micro-conduits of 700 × 250 μm2. Heat is applied to the silicon heat sink using electrical Joule-heating in a metal serpentine bridge and the heated surface temperature is monitored in real-time by Infra-red (IR) camera and electrical resistance thermometry. The experimental results for maximum and average temperatures of the chip, pressure drop, thermal resistance, average heat transfer coefficient for flow rates of 0.1, 0.2. 0.3 and 0.37 lit/min and heat fluxes from 25 to 300 W/cm2 are reported. The proposed Embedded Microchannels-3D Manifold Cooler, or EMMC, device is capable of removing 300 W/cm2 at maximum temperature 80 °C with pressure drop of less than 30 kPa, where the flow rate, inlet temperature and pressures are 0.37 lit/min, 25 °C and 350 kPa, respectively. The experimental uncertainties of the test results are estimated, and the uncertainties are the highest for heat fluxes < 50 W/cm2 due to difficulty in precisely measuring the fluid temperature at the inlet and outlet of the micro-cooler.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116523143","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Chowdhury, M. A. Hoque, J. Suhling, S. Hamasha, P. Lall
{"title":"Evolution of the Microstructure of Lead Free Solders Subjected to Both Aging and Cyclic Loading","authors":"M. Chowdhury, M. A. Hoque, J. Suhling, S. Hamasha, P. Lall","doi":"10.1115/ipack2019-6560","DOIUrl":"https://doi.org/10.1115/ipack2019-6560","url":null,"abstract":"\u0000 Currently, lead-free solders are being widely used as an alternative to traditional Sn-Pb solders in micro-electronic packaging industry due to the environmental concern of lead. Fatigue failure of solder joints is one of the common failure modes in electronic packaging which might be attributed to the experiences of thermo-mechanical fatigue (e.g. Power switching) or mechanical fatigue (e.g. vibration) loading. To design these lead-free solders more strategically for specific applications, it is important to understand the failure mechanism of lead-free solders under fatigue loading. Moreover, the microstructure and constitutive properties of conventional lead free solder joints in electronic assemblies such as SAC305 changes when exposed to isothermal aging. These changes consequently reduce the reliability of lead free electronic assemblies significantly due to aging.\u0000 In this study, we have examined the effects of prior aging on damage accumulation occurring in SAC305 and SAC_Q (SAC+Bi) solder materials subjected to mechanical cycling (fatigue testing). Uniaxial samples have been prepared and polished so that the microstructural changes could be tracked after the initial aging, and then subsequently with mechanical cycling. In particular, we have examined the microstructural changes that occurred in small fixed regions in the solder samples, rather than using several different regions. Regions of interest near the center of the sample were marked using small indents formed with a nanoindentation system. Samples were then subjected to aging at 125 °C for various durations to produce several different initial microstructures. Scanning electron microscopy (SEM) were used to investigate the aging induced microstructural changes in the regions of interest in the solder sample. After aging, the samples were then subjected to mechanical cycling. After various durations of cycling (e.g. 0, 10, 25, 50, 75, 100, 200, 300 cycles) that were below the fatigue life of the materials, the regions of interest were again examined using SEM. Using the recorded images, the microstructural evolutions in the fixed regions were observed, and the effects of the initial aging on the results were determined. In case of SAC305, It was found that the number of IMC particles decreased while the average diameter of the particles increases significantly due to the initial aging. The distribution and size of the intermetallic particles in the inter-dendritic regions were observed to remain essentially unchanged with the application of the mechanical cyclic load. Relative to the non-aged samples, there were significant differences observed in the rate and intensity of the micro crack growth occurring in the heavily aged samples that began with much coarser microstructures. Later, the cycling induced microstructure evolutions observed in the SAC_Q lead free alloy has been compared with the observed changes in the microstructure of SAC305 that occurred during the cyclic load","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114395675","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Shunsuke Kawasaki, S. Kuramoto, K. Fushinobu, Kato Koichi, Yamazaki Kimiharu, K. Hemmi
{"title":"Prediction and Control Technique of the Paper Media Temperature After Fusing in Electrophotographic Process","authors":"Shunsuke Kawasaki, S. Kuramoto, K. Fushinobu, Kato Koichi, Yamazaki Kimiharu, K. Hemmi","doi":"10.1115/ipack2019-6396","DOIUrl":"https://doi.org/10.1115/ipack2019-6396","url":null,"abstract":"\u0000 The production printer market is expected to increase due to the demand in high speed printing. In electrophotographic (EP) process, the printing speed is restricted by the toner cooling time. During continuous printing, if the printing speed is too high, following paper is printed before the toner on previous paper is solidified, which results in the adhesion of the toner on previous paper to the next paper. Therefore, it is important to reduce the toner cooling time to improve the printing speed. From the viewpoint of printing quality, although toner temperature is important in EP process, paper temperature is not. Therefore, to improve the printing speed without worsening printing quality, this report focuses on suppressing paper temperature rise after fusing, which means a method to predict paper temperature after fusing is required.\u0000 As one of effective approaches to predict paper temperature after fusing, numerical calculation based on physical model has been deployed. Constructing a physical model, however, has some problems such as complexity and uncertainty in particular parameter such as the thermal resistance. Printers have three dimensional and complex structure. The printing process itself is also a complex sequence to be appropriately modeled. It is also difficult to measure the thermal resistance and other properties due to the high speed motion of papers inside the machine. Therefore, as an alternative approach, machine learning can be used to correlate known inputs to the output temperature without relying on these uncertain parameters.\u0000 The objective of this research is to propose a new method for predicting and controlling the paper media temperature after fusing in electrophotographic process by machine learning.\u0000 Sensors are attached to the printer for the research. By using these sensors, temperature when printing is obtained. By using these data, machine learning is carried out to predict paper temperature after fusing.\u0000 This report constructs a new method to predict paper temperature after fusing. Our study demonstrates machine learning is an effective method for predicting and controlling the paper temperature after fusing.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125617440","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sadegh Khalili, S. Rangarajan, B. Sammakia, V. Gektin
{"title":"An Experimental Investigation on the Fluid Distribution in a Two-Phase Cooled Rack Under Steady and Transient IT Load","authors":"Sadegh Khalili, S. Rangarajan, B. Sammakia, V. Gektin","doi":"10.1115/ipack2019-6463","DOIUrl":"https://doi.org/10.1115/ipack2019-6463","url":null,"abstract":"\u0000 Increasing power densities in data centers due to the rise of Artificial Intelligence (AI), high-performance computing (HPC) and machine learning compel engineers to develop new cooling strategies and designs for high-density data centers. Two-phase cooling is one of the promising technologies which exploits the latent heat of the fluid. This technology is much more effective in removing high heat fluxes than when using the sensible heat of fluid and requires lower coolant flow rates. The latent heat also implies more uniformity in the temperature of a heated surface. Despite the benefits of two-phase cooling, the phase change adds complexities to a system when multiple evaporators (exposed to different heat fluxes potentially) are connected to one coolant distribution unit (CDU). In this paper, a commercial pumped two-phase cooling system is investigated in a rack level. Seventeen 2-rack unit (RU) servers from two distinct models are retrofitted and deployed in the rack. The flow rate and pressure distribution across the rack are studied in various filling ratios. Also, investigated is the transient behavior of the cooling system due to a step change in the information technology (IT) load.","PeriodicalId":397243,"journal":{"name":"ASME 2019 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems","volume":"251 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124104415","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}