生物医学工程学杂志最新文献

筛选
英文 中文
[Research progress on anti-swelling hydrogels in biomedical field]. [生物医学领域抗膨胀水凝胶的研究进展]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202312008
Changlong Song, Xiang Fu, Lu Tang, Zhihong Dong
{"title":"[Research progress on anti-swelling hydrogels in biomedical field].","authors":"Changlong Song, Xiang Fu, Lu Tang, Zhihong Dong","doi":"10.7507/1001-5515.202312008","DOIUrl":"10.7507/1001-5515.202312008","url":null,"abstract":"<p><p>Hydrogel is a kind of degradable hydrophilic polymer, but excessive hydrophilicity leads to larger volume, lower elastic modulus and looser structure, which further affect its use. Especially in the field of biomedical engineering, excessive swelling of the hydrogel can compress the nerves and improve degradation rate resulting in mismatch of tissue growth and released ions. Therefore, anti-swelling hydrogel has been a research hotspot in recent years. This paper reviews the recent research progress on anti-swelling hydrogel, and expounds the application mechanism and preparation method of hydrogel in biomedical engineering, aiming to provide some references for researchers in the field of anti-swelling hydrogel.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"848-853"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366455/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[A lightweight recurrence prediction model for high grade serous ovarian cancer based on hierarchical transformer fusion metadata]. [基于分层变换器融合元数据的高级别浆液性卵巢癌轻量级复发预测模型]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202308009
Shaoguo Cui, Yibo Tang, Haoming Wan, Rui Wang, Lili Liu
{"title":"[A lightweight recurrence prediction model for high grade serous ovarian cancer based on hierarchical transformer fusion metadata].","authors":"Shaoguo Cui, Yibo Tang, Haoming Wan, Rui Wang, Lili Liu","doi":"10.7507/1001-5515.202308009","DOIUrl":"10.7507/1001-5515.202308009","url":null,"abstract":"<p><p>High-grade serous ovarian cancer has a high degree of malignancy, and at detection, it is prone to infiltration of surrounding soft tissues, as well as metastasis to the peritoneum and lymph nodes, peritoneal seeding, and distant metastasis. Whether recurrence occurs becomes an important reference for surgical planning and treatment methods for this disease. Current recurrence prediction models do not consider the potential pathological relationships between internal tissues of the entire ovary. They use convolutional neural networks to extract local region features for judgment, but the accuracy is low, and the cost is high. To address this issue, this paper proposes a new lightweight deep learning algorithm model for predicting recurrence of high-grade serous ovarian cancer. The model first uses ghost convolution (Ghost Conv) and coordinate attention (CA) to establish ghost counter residual (SCblock) modules to extract local feature information from images. Then, it captures global information and integrates multi-level information through proposed layered fusion Transformer (STblock) modules to enhance interaction between different layers. The Transformer module unfolds the feature map to compute corresponding region blocks, then folds it back to reduce computational cost. Finally, each STblock module fuses deep and shallow layer depth information and incorporates patient's clinical metadata for recurrence prediction. Experimental results show that compared to the mainstream lightweight mobile visual Transformer (MobileViT) network, the proposed slicer visual Transformer (SlicerViT) network improves accuracy, precision, sensitivity, and F1 score, with only 1/6 of the computational cost and half the parameter count. This research confirms that the proposed algorithm model is more accurate and efficient in predicting recurrence of high-grade serous ovarian cancer. In the future, it can serve as an auxiliary diagnostic technique to improve patient survival rates and facilitate the application of the model in embedded devices.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"807-817"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366459/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113067","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Research status of lower limb exoskeleton rehabilitation robot]. [下肢外骨骼康复机器人的研究现状]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202211055
Ming Li, Hui Li, Hongliu Yu
{"title":"[Research status of lower limb exoskeleton rehabilitation robot].","authors":"Ming Li, Hui Li, Hongliu Yu","doi":"10.7507/1001-5515.202211055","DOIUrl":"10.7507/1001-5515.202211055","url":null,"abstract":"<p><p>Lower limb exoskeleton rehabilitation robots are used to improve or restore the walking and movement ability of people with lower limb movement disorders. However, the required functions for patients differ based on various diseases. For example, patients with weak muscle strength require power assistance, patients with spinal cord injuries require motion compensation, patients with gait abnormalities require gait correction, and patients with strokes require neural rehabilitation. To design a more targeted lower limb exoskeleton rehabilitation robot for different diseases, this article summarised and compared existing lower limb exoskeleton rehabilitation robots according to their main functions and the characteristics and rehabilitation needs of various lower limb movement disorders. The correlations between the functions of existing devices and diseases were summarised to provide certain references for the development of new lower limb exoskeleton rehabilitation robots.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"833-839"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366457/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Design and simulation study of positive pressure ventilation system in a simulated human biological lung]. [模拟人体生物肺内正压通气系统的设计与模拟研究]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202401063
Qincheng Yan, Quanyu Wu, Weimin Zhang, Lingjiao Pan, Xiaojie Liu, Weige Tao
{"title":"[Design and simulation study of positive pressure ventilation system in a simulated human biological lung].","authors":"Qincheng Yan, Quanyu Wu, Weimin Zhang, Lingjiao Pan, Xiaojie Liu, Weige Tao","doi":"10.7507/1001-5515.202401063","DOIUrl":"10.7507/1001-5515.202401063","url":null,"abstract":"<p><p>Simulation of the human biological lung is a crucial method for medical professionals to learn and practice the use of new pulmonary interventional diagnostic and therapeutic devices. The study on ventilation effects of the simulation under positive pressure ventilation mode provide valuable guidance for clinical ventilation treatment. This study focused on establishing an electrical simulation ventilation model, which aims to address the complexities in parameter configuration and slow display of air pressure and airflow waveforms in simulating the human biological lung under positive pressure ventilation mode. A simulated ventilation experiment was conducted under pressure-regulated volume control (PRVC) positive pressure ventilation mode, and the resulting ventilation waveform was compared with that of normal adults. The experimental findings indicated that the average error of the main reference index moisture value was 9.8% under PRVC positive pressure ventilation mode, effectively simulating the ventilatory effect observed in normal adults. So the established electrical simulation ventilation model is feasible, and provides a foundation for further research on the simulation of human biological lung positive pressure ventilation experimental platform.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"775-781"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366460/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113074","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Biomechanical study of three-dimensional printed filler block design in open wedge high tibial osteotomy]. [三维打印填充块设计在开放式楔形高胫骨截骨术中的生物力学研究]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202403056
Jing Zhang, Jianing Zhang, Lei Guo, Shibin Chen, Zhongmin Jin, Zhenxian Chen
{"title":"[Biomechanical study of three-dimensional printed filler block design in open wedge high tibial osteotomy].","authors":"Jing Zhang, Jianing Zhang, Lei Guo, Shibin Chen, Zhongmin Jin, Zhenxian Chen","doi":"10.7507/1001-5515.202403056","DOIUrl":"10.7507/1001-5515.202403056","url":null,"abstract":"<p><p>The use of a filling block can improve the initial stability of the fixation plate in the open wedge high tibial osteotomy (OWHTO), and promote bone healing. However, the biomechanical effects of filling block structures and materials on OWHTO remain unclear. OWHTO anatomical filling block model was designed and built. The finite element analysis method was adopted to study the influence of six filling block structure designs and four different materials on the stress of the fixed plate, tibia, screw, and filling block, and the micro-displacement at the wedge gap of the OWHTO fixation system. After the filling block was introduced in the OWHTO, the maximum von Mises stress of the fixation plate was reduced by more than 30%, the maximum von Mises stress of the tibia decreased by more than 15%, and the lateral hinge decreased by 81%. When the filling block was designed to be filled in the posterior position of the wedge gap, the maximum von Mises stress of the fixation system was 97.8 MPa, which was smaller than other filling methods. The minimum micro-displacement of osteotomy space was -2.9 μm, which was larger than that of other filling methods. Compared with titanium alloy and tantalum metal materials, porous hydroxyapatite material could obtain larger micro-displacement in the osteotomy cavity, which is conducive to stimulating bone healing. The results demonstrate that OWHTO with a filling block can better balance the stress distribution of the fixation system, and a better fixation effect can be obtained by using a filling block filled in the posterior position. Porous HA used as the material of the filling block can obtain a better bone healing effect.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"758-765"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366453/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Lower limb joint contact forces and ground reaction forces analysis based on Azure Kinect motion capture]. [基于 Azure Kinect 运动捕捉的下肢关节接触力和地面反作用力分析]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202311040
Yinghu Peng, Lin Wang, Zhenxian Chen, Xiaodong Dang, Fei Chen, Guanglin Li
{"title":"[Lower limb joint contact forces and ground reaction forces analysis based on Azure Kinect motion capture].","authors":"Yinghu Peng, Lin Wang, Zhenxian Chen, Xiaodong Dang, Fei Chen, Guanglin Li","doi":"10.7507/1001-5515.202311040","DOIUrl":"10.7507/1001-5515.202311040","url":null,"abstract":"<p><p>Traditional gait analysis systems are typically complex to operate, lack portability, and involve high equipment costs. This study aims to establish a musculoskeletal dynamics calculation process driven by Azure Kinect. Building upon the full-body model of the Anybody musculoskeletal simulation software and incorporating a foot-ground contact model, the study utilized Azure Kinect-driven skeletal data from depth videos of 10 participants. The in-depth videos were prepossessed to extract keypoint of the participants, which were then adopted as inputs for the musculoskeletal model to compute lower limb joint angles, joint contact forces, and ground reaction forces. To validate the Azure Kinect computational model, the calculated results were compared with kinematic and kinetic data obtained using the traditional Vicon system. The forces in the lower limb joints and the ground reaction forces were normalized by dividing them by the body weight. The lower limb joint angle curves showed a strong correlation with Vicon results (mean <i>ρ</i> values: 0.78 ~ 0.92) but with root mean square errors as high as 5.66°. For lower limb joint force prediction, the model exhibited root mean square errors ranging from 0.44 to 0.68, while ground reaction force root mean square errors ranged from 0.01 to 0.09. The established musculoskeletal dynamics model based on Azure Kinect shows good prediction capabilities for lower limb joint forces and vertical ground reaction forces, but some errors remain in predicting lower limb joint angles.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"751-757"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366463/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Detection model of atrial fibrillation based on multi-branch and multi-scale convolutional networks]. [基于多分支和多尺度卷积网络的心房颤动检测模型]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202303014
Siyu Zhao, Ming Liu, Mingqi Liu, Xiaoru Yang, Peng Xiong, Jieshuo Zhang
{"title":"[Detection model of atrial fibrillation based on multi-branch and multi-scale convolutional networks].","authors":"Siyu Zhao, Ming Liu, Mingqi Liu, Xiaoru Yang, Peng Xiong, Jieshuo Zhang","doi":"10.7507/1001-5515.202303014","DOIUrl":"10.7507/1001-5515.202303014","url":null,"abstract":"<p><p>Atrial fibrillation (AF) is a life-threatening heart condition, and its early detection and treatment have garnered significant attention from physicians in recent years. Traditional methods of detecting AF heavily rely on doctor's diagnosis based on electrocardiograms (ECGs), but prolonged analysis of ECG signals is very time-consuming. This paper designs an AF detection model based on the Inception module, constructing multi-branch detection channels to process raw ECG signals, gradient signals, and frequency signals during AF. The model efficiently extracted QRS complex and RR interval features using gradient signals, extracted P-wave and f-wave features using frequency signals, and used raw signals to supplement missing information. The multi-scale convolutional kernels in the Inception module provided various receptive fields and performed comprehensive analysis of the multi-branch results, enabling early AF detection. Compared to current machine learning algorithms that use only RR interval and heart rate variability features, the proposed algorithm additionally employed frequency features, making fuller use of the information within the signals. For deep learning methods using raw and frequency signals, this paper introduced an enhanced method for the QRS complex, allowing the network to extract features more effectively. By using a multi-branch input mode, the model comprehensively considered irregular RR intervals and P-wave and f-wave features in AF. Testing on the MIT-BIH AF database showed that the inter-patient detection accuracy was 96.89%, sensitivity was 97.72%, and specificity was 95.88%. The proposed model demonstrates excellent performance and can achieve automatic AF detection.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"700-707"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366475/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113076","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Research on dynamic blood oxygen saturation measurement based on motion noise reconstruction combined with convex combination least mean square adaptive filter]. [基于运动噪声重构结合凸组合最小均方自适应滤波器的动态血氧饱和度测量研究]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202310053
Linjia Zhang, Xiaomin Yu, Jian Lin, Chengen Chou, Zhengxian Wang
{"title":"[Research on dynamic blood oxygen saturation measurement based on motion noise reconstruction combined with convex combination least mean square adaptive filter].","authors":"Linjia Zhang, Xiaomin Yu, Jian Lin, Chengen Chou, Zhengxian Wang","doi":"10.7507/1001-5515.202310053","DOIUrl":"10.7507/1001-5515.202310053","url":null,"abstract":"<p><p>The performance of a pulse oximeter based on photoelectric detection is greatly affected by motion noise (MA) in the photoplethysmographic (PPG) signal. This paper presents an algorithm for detecting motion oxygen saturation, which reconstructs a motion noise reference signal using ensemble of complete adaptive noise and empirical mode decomposition combined with multi-scale permutation entropy, and eliminates MA in the PPG signal using a convex combination least mean square adaptive filters to calculate dynamic oxygen saturation. The test results show that, under simulated walking and jogging conditions, the mean absolute error (MAE) of oxygen saturation estimated by the proposed algorithm and the reference oxygen saturation are 0.05 and 0.07, respectively, with means absolute percentage error (MAPE) of 0.05% and 0.07%, respectively. The overall Pearson correlation coefficient reaches 0.971 2. The proposed scheme effectively reduces motion artifacts in the corrupted PPG signal and is expected to be applied in portable photoelectric pulse oximeters to improve the accuracy of dynamic oxygen saturation measurement.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"818-825"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366476/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Structural design of "fitness" and "feasibility" of body-fitted stent and its mechanical analysis]. [贴身支架 "适配性 "和 "可行性 "的结构设计及其力学分析]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202403005
Hao Sun, Keyi Tao, Zhao Liu, Tianming Du, Yanping Zhang, Shengwen Liu, Jiling Feng, Aike Qiao
{"title":"[Structural design of \"fitness\" and \"feasibility\" of body-fitted stent and its mechanical analysis].","authors":"Hao Sun, Keyi Tao, Zhao Liu, Tianming Du, Yanping Zhang, Shengwen Liu, Jiling Feng, Aike Qiao","doi":"10.7507/1001-5515.202403005","DOIUrl":"10.7507/1001-5515.202403005","url":null,"abstract":"<p><p>To address the conflict between the \"fitness\" and \"feasibility\" of body-fitted stents, this paper investigates the impact of various smoothing design strategies on the mechanical behaviour and apposition performance of stent. Based on the three-dimensional projection method, the projection region was fitted with the least squares method (fitting orders 1-6 corresponded to models 1-6, respectively) to achieve the effect of smoothing the body-fitted stent. The simulation included the crimping and expansion process of six groups of stents in stenotic vessels with different degrees of plaque calcification. Various metrics were analyzed, including bending stiffness, stent ruggedness, area residual stenosis rate, contact area fraction, and contact volume fraction. The study findings showed that the bending stiffness, stent ruggedness, area residual stenosis rate, contact area fraction and contact volume fraction increased with the fitting order's increase. Model 1 had the smallest contact area fraction and contact volume fraction, 77.63% and 83.49% respectively, in the incompletely calcified plaque environment. In the completely calcified plaque environment, these values were 72.86% and 82.21%, respectively. Additionally, it had the worst \"fitness\". Models 5 and 6 had similar values for stent ruggedness, with 32.15% and 32.38%, respectively, which indicated the worst \"feasibility\" for fabrication and implantation. Models 2, 3, and 4 had similar area residual stenosis rates in both plaque environments. In conclusion, it is more reasonable to obtain the body-fitted stent by using 2nd to 4th order fitting with the least squares method to the projected region. Among them, the body-fitted stent obtained by the 2nd order fitting performs better in the completely calcified environment.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"790-797"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366467/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113086","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
[Three-dimensional positioning and trajectory tracking of pigeons in large indoor spaces]. [鸽子在大型室内空间的三维定位和轨迹跟踪]。
生物医学工程学杂志 Pub Date : 2024-08-25 DOI: 10.7507/1001-5515.202401064
Xinyu Liu, Kaige Liu, Huanhuan Peng, Yue Qin, Xiaomin Qi, Dongyun Wang, Shengjun Wen
{"title":"[Three-dimensional positioning and trajectory tracking of pigeons in large indoor spaces].","authors":"Xinyu Liu, Kaige Liu, Huanhuan Peng, Yue Qin, Xiaomin Qi, Dongyun Wang, Shengjun Wen","doi":"10.7507/1001-5515.202401064","DOIUrl":"10.7507/1001-5515.202401064","url":null,"abstract":"<p><p>Animal localization and trajectory tracking are of great value for the study of brain spatial cognition and navigation neural mechanisms. However, traditional optical lens video positioning techniques are limited in their scope due to factors such as camera perspective. For pigeons with excellent spatial cognition and navigation abilities, based on the beacon positioning technology, a three-dimensional (3D) trajectory positioning and tracking method suitable for large indoor spaces was proposed, and the corresponding positioning principle and hardware structure were provided. The results of <i>in vitro</i> and <i>in vivo</i> experiments showed that the system could achieve centimeter-level positioning and trajectory tracking of pigeons in a space of 360 cm × 200 cm × 245 cm. Compared with traditional optical lens video positioning techniques, this system has the advantages of large space, high precision, and high response speed. It not only helps to study the neural mechanisms of pigeon 3D spatial cognition and navigation, but also has high reference value for trajectory tracking of other animals.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"715-723"},"PeriodicalIF":0.0,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366465/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142113090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信