{"title":"Regulatory requirements for therapeutic proteins: the relationship between the conformation and biological activity of filgrastim.","authors":"A F Bristow, C Bird, B Bolgiano, R Thorpe","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Higher order structure, including conformation, is considered a critical quality parameter of therapeutic proteins, and is mandatory information in development of first use and bio-similar therapeutic protein drugs, the assumption being that the biological activity of a protein is directly dependent on its adoption of a 'correct' conformation. Studies on the relationship between conformation and activity depend on the ability to induce conformational changes in proteins, and conventional approaches such as thermal or chemical denaturation are incompatible with bioactivity measurements. To explore the relationship between bio-activity and conformational studies, we have studied variants of the therapeutic protein filgrastim (rec met huGCSF) which have been mutated by the replacement of helical alanine residues with glycine, to destabilise the conformation of the molecule. In the GCSF A-G mutant series studied, single conformation-destabilising amino-acid substitutions significantly reduced the biological activity. These effects were not, however correlated with changes in secondary structure measurable by far-UV Circular Dichroism (CD) spectroscopy. Only the more extensively mutated double and triple substitutions showed measurable reductions in alpha-helical structure by CD. We conclude that in this system, GCSF does not readily adopt a reduced-activity altered conformational state which can be detected by low resolution techniques such as CD. In contrast, reductions in biological activity do reflect reductions in conformational stability, possibly caused by time-dependent degradation of the protein in the cell-proliferation bioassay. Although not a formal model of biosimilarity, we suggest that our results could inform the regulatory process in determining appropriate experimental approaches to meeting regulatory requirements for higher order structural analysis of therapeutic proteins.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"103-17"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31169403","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Calibration of the human immunoglobulin BRPs for ACA and molecular size (batch 1) and for Fc function and molecular size (batches 1 & 2).","authors":"E Sandberg, A Costanzo, A Daas, K-H Buchheit","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The current European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation batch 3 (BRP3) for Human Immunoglobulin was established in 2005. Stocks of this BRP are dwindling and a replacement batch is needed to serve as working standard in the tests for distribution of molecular size by HPLC, anticomplementary activity (ACA) and Fc function, in accordance with the requirements of the Ph. Eur. monographs Human normal immunoglobulin (0338) and Human normal immunoglobulin for intravenous administration (0918). The European Directorate for the Quality of Medicines & HealthCare (EDQM) carried out a project (BSP099) to establish replacement batches for this BRP. The project was run in 2 phases, a prequalification phase (Phase 1) and an international collaborative study (Phase 2) involving 19 laboratories. Three batches of candidate materials of various sizes, Samples A, B and C, were procured from 2 different manufacturers on the European market. Based on the results of the study, Sample A was shown to be suitable as a reference standard for the ACA test and for molecular size determination by HPLC, whereas Samples B and C were demonstrated to be suitable for the Fc function test and for the molecular size determination by HPLC. All 3 BRPs are to be used in conjunction with the monographs Human normal immunoglobulin (0338) and Human normal immunoglobulin for intravenous administration (0918). The BRPs were adopted by the Ph. Eur. Commission at its 141st session in November 2011 as official Ph. Eur. Human Immunoglobulin BRPs for ACA and molecular size Batch 1 (Sample A) and Fc function and molecular size Batch 1 and Batch 2 (Samples B and C respectively).</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"1-15"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31170023","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study of the risk of heavy metal transfer to homoeopathic mother tinctures.","authors":"J Busch, W Werner, A Huwer","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>To assess the risk of heavy metal contamination of homoeopathic mother tinctures, 9 plant species and 1 fungus used in the manufacture of homoeopathic medicaments were investigated. Mother tinctures were prepared according to the manufacturing procedures described in the European Pharmacopoeia. The original herbal drug and the material processed during production were analysed for their cadmium (Cd), lead (Pb) and mercury (Hg) content. The plant components were harvested from 2 sites contaminated by different heavy metal exposure pathways and compared with reference material from Deutsche Homöopathie-Union (DHU). It was confirmed that in all cases a significant depletion of all heavy metals studied occurred during manufacture of the mother tincture, regardless of the starting material used. In all cases, most of the heavy metal content was retained in the press cake; low levels only were detected in the mother tincture. None of the mother tinctures of plant origin exceeded the required limits, not even those of plant starting materials originating from highly contaminated sites. Substantial heavy metal concentrations could only be detected in the mother tincture of the fungus Amanita muscaria, calculated from the dry weight of the starting material. According to the results obtained, a risk-based approach to heavy metal assessment is suggested where permanent control is focused on the heavy metals accumulating in organisms such as fungi.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"55-71"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31170026","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S Vieths, D Barber, M Chapman, A Costanzo, A Daas, H Fiebig, K M Hanschmann, M Hrabina, S Kaul, A Ledesma, P Moingeon, G Reese, C Schörner, R van Ree, B Weber, K H Buchheit
{"title":"Establishment of recombinant major allergens Bet v 1 and Phl p 5a as Ph. Eur. reference standards and validation of ELISA methods for their measurement. Results from feasibility studies.","authors":"S Vieths, D Barber, M Chapman, A Costanzo, A Daas, H Fiebig, K M Hanschmann, M Hrabina, S Kaul, A Ledesma, P Moingeon, G Reese, C Schörner, R van Ree, B Weber, K H Buchheit","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The potency of allergen extracts is determined as total allergenic activity without consideration of their composition and the units differ from one manufacturer to another, making it very difficult to compare the different products. Recently, purified major allergens have been obtained by recombinant DNA technology and produced under Good Manufacturing Practice (GMP) conditions. In principle, such recombinant allergens could be established as reference standards and could help for the standardisation of the major allergen content of allergen extracts. Two recombinant major allergens, one from birch pollen, rBet v 1, and one from Timothy grass pollen, Phl p 5a, have been selected at the end of the CREATE programme as a potential starting point for the establishment as European Pharmacopoeia (Ph. Eur.) Reference Standards through a project run by the Biological Standardisation Programme (BSP) of the European Directorate for the Quality of Medicines & HealthCare (EDQM). To this end, bulk candidate recombinant materials, produced under GMP conditions, were procured from two European manufacturers and subsequently formulated and lyophilised. Four ELISA systems from three different manufacturers were included in the project, two for Bet v 1 and two for Phl p 5a with the aim of establishing reference methods for determination of the respective major antigens both in natural allergen extracts as well as in recombinant allergen products. The project was run in 3 phases: a preparatory and preliminary testing phase (feasibility phase or Phase 1), an extended feasibility phase carried out in 3 laboratories (Phase 2) to confirm the transferability of the methods and an international collaborative study with a large number of participating laboratories (Phase 3). This article describes the work done in Phase 1 and Phase 2, i.e. the physico-chemical and biological characterisation of the recombinant candidate reference standards, the assessment of their suitability for the intended purpose as well as the evaluation of the candidate ELISA systems. The results show that both candidate reference standards are suitable for the intended purpose. In addition, three out of the four ELISA systems that were included in the preliminary phase were found to be appropriate for further evaluation in the collaborative study which was organised in 2011. The results of the collaborative study will be published separately.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"118-34"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31169404","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On the formation of bromhexine impurity E and its chromatographic behaviour.","authors":"B J Venhuis, M Weda, D de Kaste, E K Lamme","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>An unknown bromhexine hydrochloride (BRH) degradation product in BRH oral solutions (finished products) was potentially related to the purity of this API. Several degradation experiments were conducted and its identity and formation were investigated using LC-DAD and LC-DAD-MS/MS. Using the LC method described in the Ph.Eur monograph BRH the degradation product was observed at RRTBRH 0.1 and the specified impurities A-D were ruled out as candidates. Impurity E was initially not considered as a candidate as EDQM reported an expected RRTBRH of 1.8. Still, the LC-DAD-MS/MS results were consistent with the M+ ion for impurity E and its expected fragment ions. Therefore, standard addition was carried out using the Ph. Eur. method which confirmed that the degradation product at RRT 0.1 was impurity E. Upon changing the column type to a column described in the knowledge database, impurity E eluted at an RRT of 1.5. Nevertheless, both columns met all of the criteria in the monograph. The formation of impurity E was even observed in BRH solutions without added reagents. As the conversion from BRH to impurity E requires a source of carbon, we suggest that one BRH molecule degrades through a radical mechanism to a reactive species which subsequently is quenched by another BRH molecule producing impurity E. We suggest the transparency list for BRH to be more explicit on the formation of impurity E, its RRT and the permissible LC columns.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"135-41"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31169405","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Collaborative study for the establishment of the 3rd international standard for dihydrostreptomycin.","authors":"G Rautmann, A Daas, K-H Buchheit","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>An international collaborative study was organised to establish the World Health Organization (WHO) 3rd International Standard (IS) for dihydrostreptomycin. Eleven laboratories from different countries participated in the collaborative study. The potency of the candidate batch, a freeze-dried preparation, was estimated by microbiological assays with sensitive microorganisms. To ensure continuity between consecutive batches of the WHO IS, the 2nd IS for dihydrostreptomycin was used as standard. Based on the results of the study, the 3rd IS for dihydrostreptomycin was adopted at the meeting of the WHO Expert Committee on Biological Standardisation (ECBS) in 2011 with an assigned anti-microbiological activity of 19425 International Units (IU) per vial. The 3rd IS for dihydrostreptomycin is available from the EDQM.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"16-38"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31170024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A multifunctional test mixture for chiral cyclodextrin GC columns.","authors":"S Wyss, I A Werner","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Gas chromatography (GC) is a powerful tool in the separation science of chiral analytes. The development of a new chiral test mixture for cyclodextrin (CD) coated GC columns allows comparing, choosing and identifying most suitable columns for a given separation challenge. This test mixture contains 12 enantiomer pairs of a broad range of functional groups and it is the first mixture suitable for all types of modified cyclodextrin capillary columns. Column changes can be observed and system performance can be monitored by means of this test mixture, which is therefore a base for reliable results. Furthermore, this publication is thought to be a start-up aid for chiral GC.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"72-86"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31170027","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Feasibility studies. The use of NMR spectrometry as a possible substitute of or complement to several analytical tests in pharmacopoeia monographs.","authors":"I McEwen, T Arvidsson","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>NMR spectrometry has many analytical applications; for instance, the identification of known substances; the structure elucidation of unknown ones; the quantification of APIs, impurities, solvent and water; kinetic studies, stereochemistry determinations, and the analyses of complex mixtures as in metabonomics. NMR spectrometry has the potential to substitute or complement existing analyses that are performed on APIs. In this work, 4 different NMR analyses were done on 2 APIs: fluvastatin sodium and benzalkonium chloride with good results.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2012 ","pages":"87-102"},"PeriodicalIF":0.0,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"31169402","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"New BRP for human plasma calibrated for coagulation factors V, VIII, XI and XIII - collaborative study for establishment of batches 1 and 2.","authors":"P Bayer, A Daas, C Milne","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A human plasma reference preparation in International Units (IU) must be used in each potency assay of the human coagulation factors V, VIII and XI in human plasma pooled and treated for virus inactivation, according to the European Pharmacopoeia (Ph. Eur.) monograph 1646 and general chapters 2.7.4 and 2.7.22 respectively, and in the potency assay of human coagulation factor XIII in fibrin sealant kits, according to Ph. Eur. monograph 0903. International reference standards for all of these factors are now established, however, regional reference standards were not available for the required routine use. It was therefore proposed by European OMCLs and manufacturers to establish a European reference preparation, and it was the goal of this study to accomplish that. Two candidate biological reference preparations (BRPs), separate lyophilisation lots of the same normal human plasma bulk material, were calibrated against the International Standards (ISs) for human coagulation factors V, VIII, XI and XIII. Twelve European laboratories including OMCLs and manufacturers participated. The candidate material was tested against the ISs in 4 separate assays for each factor using the methods described in the relevant Ph. Eur. monographs and general chapters. No discernable difference was noted between the activities of the 2 candidates. They were shown to be suitable for their intended use and it was recommended to assign to both batches a potency of 0.73 IU/mL for factor V, 0.74 IU/mL for factor VIII, 0.59 IU/mL for factor XI and 0.79 IU/mL for factor XIII. Candidate batch B is proposed to be used first as lot 1, followed upon its depletion by candidate batch A (lot 2). The BRP batches will be monitored regularly for potency throughout their lifetime. EDQM BRP batches 1 and 2 of coagulation factors V, VIII, XI and XIII plasma were formally adopted by the Ph. Eur. Commission at their session in June 2011.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2011 2","pages":"16-25"},"PeriodicalIF":0.0,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30369799","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Biological indicators, tools to verify the effect of sterilisation processes - position paper prepared on behalf of group 1 (biological methods and statistical analysis).","authors":"K Haberer, H van Doorne","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Biological indicators (BIs) are test systems containing viable microorganisms (usually spores of bacteria) providing a defined challenge to a specified sterilisation process. General chapter 5.1.2 of the European Pharmacopoeia [1] (Ph. Eur.) sets specifications for BIs and gives some guidance for their use. As shown in this text, the approach followed by Ph. Eur. as well as by ISO standards is outdated and could create nowadays some confusion among the users of the pharmacopoeia. It is the objective of this paper to provide the theoretical background of BIs as tools for the design and qualification of reliable moist heat sterilisation processes. The principles laid down in this article will form the basis of a future draft on a revised chapter on BIs in Pharmeuropa.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2011 2","pages":"26-39"},"PeriodicalIF":0.0,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"30369800","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}