F. Amzajerdian, H. Hamedani, R. Baron, Y. Xin, T. Achekzai, L. Loza, M. Ismail, I. Duncan, S. Kadlecek, K. Ruppert, R. Rizi
{"title":"Preliminary Assessment of Gas Exchange Efficiency in Lung Transplant Patients with Multi-breath Xenon Polarization Transfer Contrast Imaging","authors":"F. Amzajerdian, H. Hamedani, R. Baron, Y. Xin, T. Achekzai, L. Loza, M. Ismail, I. Duncan, S. Kadlecek, K. Ruppert, R. Rizi","doi":"10.58530/2022/1885","DOIUrl":"https://doi.org/10.58530/2022/1885","url":null,"abstract":"Quantifying the exchange of hyperpolarized xenon gas between the airways, lung parenchyma, and red blood cells may provide valuable insights into the progression of lung graft failure, enabling earlier diagnosis of chronic lung allograft dysfunction (CLAD). By combining Xenon polarization Transfer Contrast (XTC) imaging with a multi-breath model of fractional ventilation, gas exchange efficiency was assessed in four lung transplant recipients 3-12 months post-surgery in order to identify baseline metrics and trends.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115425514","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Emile Kadalie, A. Trotier, Nadège Corbin, S. Miraux, E. Ribot
{"title":"Respiration artifact-free 3D DESS T2 mapping of the human brain","authors":"Emile Kadalie, A. Trotier, Nadège Corbin, S. Miraux, E. Ribot","doi":"10.58530/2022/0760","DOIUrl":"https://doi.org/10.58530/2022/0760","url":null,"abstract":"The Dual Echo Steady State (DESS) sequence has the potential to be used for 3D human brain imaging and 3D T2 mapping. It is however known to be sensitive to respiration. The DESS sequence was therefore modified to include a self-gating approach in order to investigate the influence of breathing on brain images and then extract artifact-free images. To apply this method for high resolution T2 mapping at 3T, an acceleration method compatible with Compressed Sensing was implemented to maintain a clinically acceptable acquisition time.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"285 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115430282","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Miguel Romanello Giroud Joaquim, E. Furth, Yong Fan, H. K. Song, S. Pickup, Jianbo Cao, Hoon Choi, Mamta Gupta, C. Clendenin, T. Karasic, J. Duda, James Gee, P. O’Dwyer, M. Rosen, Rongchao Zhou
{"title":"DWI Metrics Differentiating Intraductal Papillary Mucinous Neoplasms from Pancreatic Cancer: A study in GEM Models","authors":"Miguel Romanello Giroud Joaquim, E. Furth, Yong Fan, H. K. Song, S. Pickup, Jianbo Cao, Hoon Choi, Mamta Gupta, C. Clendenin, T. Karasic, J. Duda, James Gee, P. O’Dwyer, M. Rosen, Rongchao Zhou","doi":"10.58530/2022/3430","DOIUrl":"https://doi.org/10.58530/2022/3430","url":null,"abstract":"Intraductal Papillary Mucinous Neoplasms (IPMN) are recognized as important precursors to invasive pancreatic ductal adenocarcinoma (PDAC). While IPMN requires surveillance without treatment, a clinical marker is lacking which can identify those undergoing malignant transformation. In two genetic engineered mouse models (KPC and CKS), which resemble human PDAC and IPMN, respectively, we tested the hypothesis that differences in cellular architecture and stromal features between PDAC and IPMN present themselves in DW-MRI and /or DCE-MRI metrics. Our data revealed an almost complete separation of ADC values between CKS (benign) vs. KPC (malignant) tumors and identified histopathological features corroborating the imaging metrics.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"96 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115690686","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Anaïs Artiges, F. Mauconduit, I. Uszynski, Baptiste Mulot, E. Chaillou, P. Ciuciu, C. Poupon
{"title":"Ginkgo: a novel modular and and Open Source MRI pulse sequence development framework dedicated to MRI systems","authors":"Anaïs Artiges, F. Mauconduit, I. Uszynski, Baptiste Mulot, E. Chaillou, P. Ciuciu, C. Poupon","doi":"10.58530/2022/2778","DOIUrl":"https://doi.org/10.58530/2022/2778","url":null,"abstract":"We created a new object-oriented environment for MR pulse-sequence development based on IDEA VE11C and above versions using an Open Science philosophy. This Ginkgo toolkit uses a modular structure to facilitate the design of pulse sequences using the aggregation of basic open-source sequence blocks available from the toolkit. Proofs of concept of the productivity gain reached using Ginkgo are provided through the implementation of a series of sequence models including a diffusion-weighted PGSE 3D EPI sequence.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115703918","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Dicheng Chen, Wanqi Hu, Huiting Liu, Tianyu Qiu, Yihui Huang, L. Lin, D. Guo, Jianzhong Lin, X. Qu
{"title":"MRS Denoising Model: ReLSTM-Net Trained by few In vivo Measured Data","authors":"Dicheng Chen, Wanqi Hu, Huiting Liu, Tianyu Qiu, Yihui Huang, L. Lin, D. Guo, Jianzhong Lin, X. Qu","doi":"10.58530/2022/3185","DOIUrl":"https://doi.org/10.58530/2022/3185","url":null,"abstract":"1H Magnetic Resonance Spectroscopy (MRS) suffers low Signal-Noise Ratio (SNR) due to low concentrations of metabolites. To improve the SNR, the current mainstream is to do Signal Averaging with repeated samplings but it is time-consuming. Therefore, we designed a novel denoising ReLSTM-Net to learn the mapping from the low SNR MRS to the high SNR one in the time-domain by a few in vivo measured data. Denoised spectra by the proposed method has higher accuracy and reliability in quantifying metabolites Glx, tCho and mI, compared with the state-of-art Low-Rank method.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115706771","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kristina M. Zvolanek, Stefano Moia, Rachael C. Stickland, C. Caballero-Gaudes, M. Bright
{"title":"Respiration volume per time (RVT) as a surrogate for end-tidal CO2 to map hemodynamic lag with BOLD fMRI","authors":"Kristina M. Zvolanek, Stefano Moia, Rachael C. Stickland, C. Caballero-Gaudes, M. Bright","doi":"10.58530/2022/1673","DOIUrl":"https://doi.org/10.58530/2022/1673","url":null,"abstract":"Using a breath-hold task to modulate end-tidal CO2 during a BOLD fMRI scan is an established method to map hemodynamic lag. However, end-tidal CO2 measurements may not be reliable in less compliant subjects and require additional monitoring equipment. We investigated whether a related metric, respiration volume per time (RVT) can be used as a surrogate for end-tidal CO2 by directly comparing the lag values derived from each physiological measurement. Similar spatial variation was observed in healthy adult participants, albeit with some degree of proportional bias, indicating respiration belt data can be used as an alternative to map hemodynamic lag.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124407350","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Wenjun Wang, V. Zhurbenko, Juan Diego Sanchez Heredia, Jan Ardenkjær Larsen
{"title":"Effect of Matching Network Losses on preamplifier decoupling circuit topologies at room and cryogenic temperature for 3 T 13C applications","authors":"Wenjun Wang, V. Zhurbenko, Juan Diego Sanchez Heredia, Jan Ardenkjær Larsen","doi":"10.58530/2022/2262","DOIUrl":"https://doi.org/10.58530/2022/2262","url":null,"abstract":"The SNR performances of a three- and a four-element matching circuit topologies are compared for the case of 3 T 13C imaging. The benefit to SNR of cryogenic cooling is also compared against the choice of matching networks. Results show that while cryogenic cooling can improve the output SNR by 2–3 dB, a less lossy matching network design can improve the SNR performance by 7–8 dB. The importance of matching network design ought not to be dismissed.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123039286","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Volumetric Renal Perfusion Imaging with pCASL – Comparison of 3D TSE and 3D GraSE Readout","authors":"Limin Zhou, Yiming Wang, A. Madhuranthakam","doi":"10.58530/2022/4878","DOIUrl":"https://doi.org/10.58530/2022/4878","url":null,"abstract":"Recent consensus recommended SE-EPI as the preferred readout for 2D single-slice renal perfusion imaging using pCASL. Compared to single-slice 2D acquisition, 3D acquisitions can achieve higher SNR, larger slice coverage, and optimal background suppression in similar scan times. In this study, we compared 3D GRASE, the recommended 3D readout for brain perfusion imaging, with an optimized 3D TSE readout using Cartesian acquisition with spiral profile reordering and Variable Density Sampling (VD-CASPR) in 4 healthy volunteers for volumetric renal perfusion imaging. Results showed that 3D pCASL with TSE VD-CASPR is more robust and has higher SNR than 3D pCASL with GRASE.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"294 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123048016","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Josephine L Tan, A. Akbari, M. Fox, M. Gaed, M. Moussa, J. Gómez, Z. Kassam, W. Pavlosky, Joseph L K Chin, S. Pautler, Nicholas Power, A. Ward, G. Bauman, J. Thiessen, T. Scholl
{"title":"Multiparametric MRI, sodium MRI, and PSMA PET of prostate cancer with histological validation of Gleason grade","authors":"Josephine L Tan, A. Akbari, M. Fox, M. Gaed, M. Moussa, J. Gómez, Z. Kassam, W. Pavlosky, Joseph L K Chin, S. Pautler, Nicholas Power, A. Ward, G. Bauman, J. Thiessen, T. Scholl","doi":"10.58530/2022/1294","DOIUrl":"https://doi.org/10.58530/2022/1294","url":null,"abstract":"This abstract focuses on the development of an imaging assay based on multiparametric MRI and sodium (23Na) MRI to discriminate between low- and high-grade prostate cancer (PCa) lesions, using Gleason grade defined by whole-mount histopathology as the gold standard and PET targeting the prostate-specific membrane antigen (PSMA) as a validation. Data from the first patient (Gleason score 7) demonstrates that PSMA-PET may be superior in detecting PCa lesions in the transition zone and distant metastases while the sensitivity of the current 23Na radiofrequency system in this study is limited to lesions in the peripheral zone of the prostate.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114648397","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Reduced field-of-view diffusion-weighted MRI improving diagnostic value in cervical cancer","authors":"Huihui Wang, J. Qiu","doi":"10.58530/2022/4236","DOIUrl":"https://doi.org/10.58530/2022/4236","url":null,"abstract":"This study was aimed to investigate the image quality and signal intensity (SI) of reduced field-of-view (r-FOV) DWI in patients with cervical cancer in comparison with full FOV (f-FOV) DWI. The subjective image quality, quantitative tumor conspicuity and quantitative normal tissue contrast were better for the r-FOV DWI images than for f-FOV DWI. The tumour diameters measured from the r-FOV DWI images experienced less bias than those from the f-FOV DWI. Those suggest that r-FOV DWI improving diagnostic value in cervical cancer than f-FOV DWI.","PeriodicalId":391925,"journal":{"name":"ISMRM Annual Meeting","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114648404","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}