Factors Affecting Lethal Isotherms During Cryoablation Procedures. 冷冻消融过程中影响致死等温线的因素。
Open Biomedical Engineering Journal Pub Date : 2016-06-29 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010062
Andrew C Rau, Ryan Siskey, Jorge A Ochoa, Tracy Good
{"title":"Factors Affecting Lethal Isotherms During Cryoablation Procedures.","authors":"Andrew C Rau,&nbsp;Ryan Siskey,&nbsp;Jorge A Ochoa,&nbsp;Tracy Good","doi":"10.2174/1874120701610010062","DOIUrl":"https://doi.org/10.2174/1874120701610010062","url":null,"abstract":"<p><strong>Background: </strong>Creating appropriately-sized, lethal isotherms during cryoablation of renal tumors is critical in order to achieve sufficiently-sized zones of cell death. To ensure adequate cell death in target treatment locations, surgeons must carefully select the type, size, location, and number of probes to be used, as well as various probe operating parameters.</p><p><strong>Objective: </strong>The current study investigates the effects of probe type, operating pressure, and clinical method on the resulting sizes of isotherms in an in vitro gelatin model.</p><p><strong>Method: </strong>Using a total of four cryoprobes from two manufacturers, freeze procedures were conducted in gelatin in order to compare resulting sizes of constant temperature zones (isotherms). The effects of certain procedural parameters which are clinically adjustable were studied.</p><p><strong>Results: </strong>Test results show that the sizes of 0 °C,-20 °C and -40 °C isotherms created by similarly-sized probes from two different manufacturers were significantly different for nearly all comparisons made, and that size differences resulting from changing the operating pressure were not as prevalent. Furthermore, isotherm sizes created using a multiple freeze procedure (a ten minute freeze, followed by a five minute passive thaw, followed by another ten minute freeze) did not result in statistically-significant differences when compared to those created using a single freeze procedure in all cases.</p><p><strong>Conclusion: </strong>These results indicate that selection of the probe manufacturer and probe size may be more important for dictating the size of kill zones during cryoablation than procedural adjustments to operating pressures or freeze times.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"62-71"},"PeriodicalIF":0.0,"publicationDate":"2016-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/67/46/TOBEJ-10-62.PMC4994113.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34699476","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Engineering Approach to Identifying Patients with Colon Tumors on the Basis of Electrophotonic Imaging Technique Data. 基于电泳成像技术数据识别结肠肿瘤患者的工程方法。
Open Biomedical Engineering Journal Pub Date : 2016-06-29 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010072
E G Yakovleva, K G Korotkov, E D Fedorov, E V Ivanova, R V Plahov, S S Belonosov
{"title":"Engineering Approach to Identifying Patients with Colon Tumors on the Basis of Electrophotonic Imaging Technique Data.","authors":"E G Yakovleva,&nbsp;K G Korotkov,&nbsp;E D Fedorov,&nbsp;E V Ivanova,&nbsp;R V Plahov,&nbsp;S S Belonosov","doi":"10.2174/1874120701610010072","DOIUrl":"https://doi.org/10.2174/1874120701610010072","url":null,"abstract":"<p><strong>Background: </strong>Colonic neoplasms are quite a serious problem today. Screening methods play an important role in diagnosing the disease. Colorectal cancer screening is a complex undertaking, having various options, which require a lot of efforts both from the doctor and from the patient, including the use of sedatives and the necessity of the presence of an assistant for some procedures such as colonoscopy. This is why it is very important to find a method by which one can make a diagnosis quickly, easily, and painlessly.</p><p><strong>Methods: </strong>The ability to identify patients with tumors of the colon using the Electrophotonic Imaging (EPI) technique, as well as using it for differential diagnosis of tumors of the colon by their morphology, size and quantity was investigated. Selection of the most significant parameters of the EPI-graphy for the separation of the control group and the group of patients with tumors of the colon was developed. 137 people were studied with the EPI camera, with ages ranging from 16 to 86 years, including 49 males and 88 females. Based on the results of the colonoscopy and histological findings all subjects were divided into 2 groups: control group of 55 people, 9 males, 46 females; and patients with tumors (benign or malignant) of the colon - 82 people; 40 males and 42 females. Then all subjects were divided into smaller groups based on morphology, size, number of tumors and localization.</p><p><strong>Results: </strong>Based on the identified indicators decision rules to determine the patients with tumors of the colon were constructed. The specificity of the resulting function was 80.0% and sensitivity 75.6%. Decision rule was built as well with logistic regression. The specificity of the resulting function was 78.2% and sensitivity 90.0%. The accuracy of this approach was higher than using discriminant analysis.</p><p><strong>Conclusions: </strong>The results of this study have proven the ability to identify patients with tumors of the colon using EPI technology, as well as use it for differential diagnosis of tumors of the colon by their morphology, size and quantity. EPI testing is non-invasive, takes less than five minutes, and equipment is relatively cheap and accessible in mass production. This opens up good prospects for further research for implementation as a first step of the screening process. This paper presents the pilot study developing methodological approach to the GDV data processing. That is why we tried different methods of data processing. At the same time we do not pretend to develop a diagnostic method - sample size is too small for this, and other cancer types were not studied. Further research is needed.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"72-80"},"PeriodicalIF":0.0,"publicationDate":"2016-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f1/2f/TOBEJ-10-72.PMC4994194.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34699477","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Alternating Periods of High and Low-Entropy Neural Ensemble Activity During Image Processing in the Primary Visual Cortex of Rats. 大鼠初级视觉皮层图像处理过程中高、低熵神经集成活动的交替周期。
Open Biomedical Engineering Journal Pub Date : 2016-06-09 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010051
Xiaoyuan Li, Qiwei Li, Li Shi, Liucheng Jiao
{"title":"Alternating Periods of High and Low-Entropy Neural Ensemble Activity During Image Processing in the Primary Visual Cortex of Rats.","authors":"Xiaoyuan Li,&nbsp;Qiwei Li,&nbsp;Li Shi,&nbsp;Liucheng Jiao","doi":"10.2174/1874120701610010051","DOIUrl":"https://doi.org/10.2174/1874120701610010051","url":null,"abstract":"<p><p>The response properties of individual neurons in the primary visual cortex (V1) are among the most thoroughly described in the mammalian central nervous system, but they reveal less about higher-order processes like visual perception. Neural activity is highly nonlinear and non-stationary over time, greatly complicating the relationships among the spatiotemporal characteristics of visual stimuli, local field potential (LFP) signal components, and the underlying neuronal activity patterns. We applied discrete wavelet transformation to detect new features of the LFP that may better describe the association between visual input and neural ensemble activity. The relative wavelet energy (RWE), wavelet entropy (WS), and the mean WS were computed from LFPs recorded in rat V1 during three distinct visual stimuli: low ambient light, a uniform grey computer screen, and simple pictures of common scenes. The time evolution of the RWE within the γ band (31-62.5 Hz) was the dominant component over certain periods during visual stimulation. Mean WS decreased with increasing complexity of the visual image, and the time-dependent WS alternated between periods of highly ordered and disordered population activity. In conclusion, these alternating periods of high and low WS may correspond to different aspects of visual processing, such as feature extraction and perception. </p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"51-61"},"PeriodicalIF":0.0,"publicationDate":"2016-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/af/16/TOBEJ-10-51.PMC4901198.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34612190","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Automatic Identification of the Repolarization Endpoint by Computing the Dominant T-wave on a Reduced Number of Leads. 基于减少导联数的优势t波的复极端点自动识别。
Open Biomedical Engineering Journal Pub Date : 2016-04-30 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010043
C Giuliani, A Agostinelli, F Di Nardo, S Fioretti, L Burattini
{"title":"Automatic Identification of the Repolarization Endpoint by Computing the Dominant T-wave on a Reduced Number of Leads.","authors":"C Giuliani,&nbsp;A Agostinelli,&nbsp;F Di Nardo,&nbsp;S Fioretti,&nbsp;L Burattini","doi":"10.2174/1874120701610010043","DOIUrl":"https://doi.org/10.2174/1874120701610010043","url":null,"abstract":"Electrocardiographic (ECG) T-wave endpoint (Tend) identification suffers lack of reliability due to the presence of noise and variability among leads. Tend identification can be improved by using global repolarization waveforms obtained by combining several leads. The dominant T-wave (DTW) is a global repolarization waveform that proved to improve Tend identification when computed using the 15 (I to III, aVr, aVl, aVf, V1 to V6, X, Y, Z) leads usually available in clinics, of which only 8 (I, II, V1 to V6) are independent. The aim of the present study was to evaluate if the 8 independent leads are sufficient to obtain a DTW which allows a reliable Tend identification. To this aim Tend measures automatically identified from 15-dependent-lead DTWs of 46 control healthy subjects (CHS) and 103 acute myocardial infarction patients (AMIP) were compared with those obtained from 8-independent-lead DTWs. Results indicate that Tend distributions have not statistically different median values (CHS: 340 ms vs. 340 ms, respectively; AMIP: 325 ms vs. 320 ms, respectively), besides being strongly correlated (CHS: ρ=0.97, AMIP: 0.88; P<10-27). Thus, measuring Tend from the 15-dependent-lead DTWs is statistically equivalent to measuring Tend from the 8-independent-lead DTWs. In conclusion, for the clinical purpose of automatic Tend identification from DTW, the 8 independent leads can be used without a statistically significant loss of accuracy but with a significant decrement of computational effort. The lead dependence of 7 out of 15 leads does not introduce a significant bias in the Tend determination from 15 dependent lead DTWs.","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"43-50"},"PeriodicalIF":0.0,"publicationDate":"2016-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1874120701610010043","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34612189","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Ex Vivo Dermis Mechanical Behavior in Relation to Decellularization Treatment Length. 离体真皮力学行为与脱细胞处理时间的关系。
Open Biomedical Engineering Journal Pub Date : 2016-04-08 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010034
Mara Terzini, Cristina Bignardi, Carlotta Castagnoli, Irene Cambieri, Elisabetta M Zanetti, Alberto L Audenino
{"title":"<i>Ex Vivo</i> Dermis Mechanical Behavior in Relation to Decellularization Treatment Length.","authors":"Mara Terzini,&nbsp;Cristina Bignardi,&nbsp;Carlotta Castagnoli,&nbsp;Irene Cambieri,&nbsp;Elisabetta M Zanetti,&nbsp;Alberto L Audenino","doi":"10.2174/1874120701610010034","DOIUrl":"https://doi.org/10.2174/1874120701610010034","url":null,"abstract":"<p><strong>Background: </strong>The dermis is a commonly used source tissue for biologic scaffolds; all cellular and nuclear materials need to be removed to limit the inflammatory immune response by the host organism. The decellularization is critical because it must preserve the structural integrity of the extracellular matrix. This work has analyzed a decellularization procedure commonly followed for the dermal tissue that is a chemical treatment with sodium hydroxide. The goal of this work is to identify the optimal treatment length on the basis of structural properties.</p><p><strong>Methods: </strong>Tensile tests have been performed on the native tissue and on tissues decellularized for 1-7 weeks in sodium hydroxide. The collected data have been analyzed through Tukey-Kramer test to assess if the mechanical properties (ultimate tensile stress and elastic modulus) of decellularized tissues were significantly different from the properties of the native tissue. These tests have been performed on specimens cut along two orthogonal directions (parallel and perpendicular to Langer's lines).</p><p><strong>Results: </strong>The decellularization treatment performed with sodium hydroxide in general weakens the tissue: both the ultimate stress and the elastic modulus get lower. The structural properties along Langer lines orientation are more strongly impacted, while the structural properties orthogonal to Langer lines can be preserved with an optimal duration of the decellularization treatment that is 5-6 weeks.</p><p><strong>Conclusion: </strong>The duration of the decellularization treatment is critical not only to reach a complete decellularization, but also to preserve the mechanical properties of the tissue; 5-6 week treatment performed with sodium hydroxide allows preserving the mechanical properties of the native tissue perpendicularly to Langer lines orientation, and minimizing the impact of the decellularization process on the mechanical properties along the Langer lines orientation.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"34-42"},"PeriodicalIF":0.0,"publicationDate":"2016-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c4/92/TOBEJ-10-34.PMC5395843.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34977352","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Modeling of Drug Delivery by A Pump Driven Micro-Needle Array System. 泵驱动微针阵列给药系统的建模。
Open Biomedical Engineering Journal Pub Date : 2016-03-30 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010019
Kai Chen, Min Pan, Zhi-Gang Feng
{"title":"Modeling of Drug Delivery by A Pump Driven Micro-Needle Array System.","authors":"Kai Chen,&nbsp;Min Pan,&nbsp;Zhi-Gang Feng","doi":"10.2174/1874120701610010019","DOIUrl":"https://doi.org/10.2174/1874120701610010019","url":null,"abstract":"<p><strong>Background: </strong>Micro-needles were proposed as one of the alternatives to deliver drugs painlessly passing through stratum corneum in recent years. In this work, a mathematical model is presented to characterize the in fusion flow of a hollow micro-needle array driven by a micro-pump.</p><p><strong>Methods: </strong>By assuming the injection of each micro-needle undergoes a spherical expansion and diffusion, the model is able to calculate the time-varying expansion radius, and the diffusion boundary, provided that the material properties and the micro-needle system parameters are known.</p><p><strong>Results and conclusion: </strong>The calculation results show that the expansion caused by the infusion of micro-needles stops and the flow rate drops to zero in a short time. However, the diffusion boundary is much bigger than the expansion and the infusion continues if the surrounding material is absorptive. The experimental results of jet infusion through a single needle in silicon rubber and polyacrylamide gel agree with the calculation results qualitatively.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"19-33"},"PeriodicalIF":0.0,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1874120701610010019","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34612187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
The Pratt Pouch Provides a Three-Fold Access Increase to Antiretroviral Medication for Births outside Health Facilities in Southern Zambia. Pratt Pouch 为赞比亚南部医疗机构以外的产妇提供了三倍的抗逆转录病毒药物。
Open Biomedical Engineering Journal Pub Date : 2016-03-22 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010012
Alexander P Dahinten, Robert A Malkin
{"title":"The Pratt Pouch Provides a Three-Fold Access Increase to Antiretroviral Medication for Births outside Health Facilities in Southern Zambia.","authors":"Alexander P Dahinten, Robert A Malkin","doi":"10.2174/1874120701610010012","DOIUrl":"10.2174/1874120701610010012","url":null,"abstract":"<p><strong>Introduction: </strong>Modern day antiretroviral therapy allows HIV+ pregnant women to lower the likelihood of viral transmission to their infants before, during, and after birth from 20-45% to less than 5%. In developing countries, where non-facility births may outnumber facility births, infant access to safe antiretroviral medication during the critical first three days after birth is often limited. A single-dose, polyethylene pouch (\"Pratt Pouch\") addresses this challenge by allowing the medication to be distributed to mothers during antenatal care.</p><p><strong>Methods: </strong>The Pratt Pouch was introduced as part of a one year clinical feasibility study in two districts in Southern Province, Zambia. Participating nurses, community health workers, and pharmacists were trained before implementation. Success in achieving improved antiretroviral medication access was assessed via pre intervention and post intervention survey responses by HIV+ mothers.</p><p><strong>Results: </strong>Access to medication for HIV-exposed infants born outside of a health facility increased from 35% (17/51) before the introduction of the pouch to 94% (15/16) after (p<0.05). A non-significant increase in homebirth rates from 33% (pre intervention cohort) to 50% (post intervention cohort) was observed (p>0.05). Results remained below the national average homebirth rate of 52%. Users reported minimal spillage and a high level of satisfaction with the Pratt Pouch.</p><p><strong>Conclusion: </strong>The Pratt Pouch enhances access to infant antiretroviral medication in a rural, non-facility birth setting. Wide scale implementation could have a substantial global impact on HIV transmission rates from mother to child.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"12-8"},"PeriodicalIF":0.0,"publicationDate":"2016-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0d/ef/TOBEJ-10-12.PMC4807409.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34398543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Bone Defect Regeneration by a Combination of a β-Tricalcium Phosphate Scaffold and Bone Marrow Stromal Cells in a Non-Human Primate Model. 非人灵长类动物模型中β-磷酸三钙支架与骨髓基质细胞联合再生骨缺损的研究。
Open Biomedical Engineering Journal Pub Date : 2016-03-18 eCollection Date: 2016-01-01 DOI: 10.2174/1874120701610010002
Tomokazu Masaoka, Toshitaka Yoshii, Masato Yuasa, Tsuyoshi Yamada, Takashi Taniyama, Ichiro Torigoe, Kenichi Shinomiya, Atsushi Okawa, Sadao Morita, Shinichi Sotome
{"title":"Bone Defect Regeneration by a Combination of a β-Tricalcium Phosphate Scaffold and Bone Marrow Stromal Cells in a Non-Human Primate Model.","authors":"Tomokazu Masaoka,&nbsp;Toshitaka Yoshii,&nbsp;Masato Yuasa,&nbsp;Tsuyoshi Yamada,&nbsp;Takashi Taniyama,&nbsp;Ichiro Torigoe,&nbsp;Kenichi Shinomiya,&nbsp;Atsushi Okawa,&nbsp;Sadao Morita,&nbsp;Shinichi Sotome","doi":"10.2174/1874120701610010002","DOIUrl":"https://doi.org/10.2174/1874120701610010002","url":null,"abstract":"<p><strong>Background: </strong>Reconstruction of large bone defects is a great challenge in orthopedic research. In the present study, we prepared composites of bone marrow-derived stromal cells (BMSCs) and β-tricalcium phosphate (β-TCP) with three novel aspects: proliferation of BMSCs with continuous dexamethasone treatment, cell loading under low pressure, and use of autologous plasma as the cell loading medium. The effectiveness of the resulting composite for large bone-defect reconstruction was tested in a non-human primate model, and the bone union capability of the regenerated bones was examined.</p><p><strong>Materials and methods: </strong>Primary surgery: Bone defects (5 cm long) were created in the left femurs of nine cynomolgus monkeys with resection of the periosteum (five cases) or without resection (four cases), and porous β-TCP blocks were transplanted into the defects. Secondary surgery: Bone marrow aspirates harvested from seven of the nine monkeys were cultured with dexamethasone, and BMSCs were obtained. BMSCs were suspended in autologous plasma and introduced into a porous β-TCP block under low-pressure conditions. The BMSC/β-TCP composites were transplanted into bone defects created at the same sites as the primary surgery. Bone union evaluation: Five regenerated femurs were shortened by osteotomy surgery 8 to 15 months after transplantation of the β-TCP/BMSC composites, and bone union was evaluated radiographically.</p><p><strong>Results: </strong>After the primary surgery and treatment with β-TCP alone, one of the five periosteum-resected monkeys and two of the four periosteum-preserved monkeys exhibited successful bone reconstruction. In contrast, five of the seven cases treated with the β-TCP/MSC composite showed successful bone regeneration. In four of the five osteotomy cases, bone union was confirmed.</p><p><strong>Conclusion: </strong>We validated the effectiveness of a novel β-TCP/BMSC composite for large bone defect regeneration and confirmed the bone union capability of the regenerated bone.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"2-11"},"PeriodicalIF":0.0,"publicationDate":"2016-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/8d/6f/TOBEJ-10-2.PMC4800777.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34398542","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 23
Optimization of Extraction Process for Polysaccharide in Salvia Miltiorrhiza Bunge Using Response Surface Methodology. 响应面法优化丹参多糖的提取工艺。
Open Biomedical Engineering Journal Pub Date : 2015-10-30 eCollection Date: 2015-01-01 DOI: 10.2174/1874120701509010347
Wang Yanhua, Wu Fuhua, Guo Zhaohan, Peng Mingxing, Zhang Yanan, Pang Zhen Ling, Du Minhua, Zhang Caiying, Liang Zian
{"title":"Optimization of Extraction Process for Polysaccharide in Salvia Miltiorrhiza Bunge Using Response Surface Methodology.","authors":"Wang Yanhua, Wu Fuhua, Guo Zhaohan, Peng Mingxing, Zhang Yanan, Pang Zhen Ling, Du Minhua, Zhang Caiying, Liang Zian","doi":"10.2174/1874120701509010347","DOIUrl":"10.2174/1874120701509010347","url":null,"abstract":"<p><p>This study was aimed to optimize the extraction process for Salvia miltiorrhiza Bunge polysaccharide using response surface methodology The results showed that four operating parameters including microwave power, microwave time and the particle size had notable effects on the polysaccharide extraction of Salvia miltiorrhiza Bunge. The effects could be ranked in decreasing order of importance as follows:. Microwave power > microwave time > the comminution degree. The optimal extraction parameters were determined as 573.83W of Microwave power and 8.4min of microwave time and 67.51mesh of the comminution degree, resulting in the yield of Salvia miltiorrhiza Bunge polysaccharide of 101.161mg / g. The established regression model describing polysaccharide extraction from as a function of the three extraction parameters was highly significant (R 2 = 0.9953). The predicted and experimental results were found to be in good agreement. Thus, the model can be applicable for the prediction of polysaccharide extraction from Salvia miltiorrhiza Bunge. </p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"9 ","pages":"347-53"},"PeriodicalIF":0.0,"publicationDate":"2015-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4787276/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71427612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
The Reasearch on the Anti-Fatigue Effect of Whey Protein Powder in Basketball Training. 乳清蛋白粉在篮球训练中抗疲劳作用的研究。
Open Biomedical Engineering Journal Pub Date : 2015-10-26 eCollection Date: 2015-01-01 DOI: 10.2174/1874120701509010330
Sun Ronghui
{"title":"The Reasearch on the Anti-Fatigue Effect of Whey Protein Powder in Basketball Training.","authors":"Sun Ronghui","doi":"10.2174/1874120701509010330","DOIUrl":"https://doi.org/10.2174/1874120701509010330","url":null,"abstract":"<p><p>In order to observe the effects of whey protein powder on hematological indexes of players majoring in physical education in the basketball training, the authors divided the players randomly into a control group and a nutrition group. Athletes complete the 30 minutes quantitative exercise using cycle ergometer respectively before the trial and after one month trial. Then we exsanguinated immediately after exercise, extracted heparin and measured hemoglobin, red blood cell count, hematocrit and mean corpuscular volume and other hematological indices. The results showed that after taking whey protein powder, the HB, RBC, HCT of nutrition group was significantly higher that the control group. This suggests that in high-intensity training, taking whey protein powder can cause changes of HB, RBC and HCT in human body, meanwhile MCV essentially the same. So whey protein powder can improve exercise capacity, and has anti-fatigue effect. </p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"9 ","pages":"330-4"},"PeriodicalIF":0.0,"publicationDate":"2015-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4787274/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71427615","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信