2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)最新文献

筛选
英文 中文
Probabilistic edge detection in 3D optical microscopy images of tissue samples 组织样本三维光学显微镜图像的概率边缘检测
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-07-23 DOI: 10.1109/ISBI.2015.7164152
Kaustav Nandy, Prabhakar R. Gudla, R. Chellappa, S. Lockett
{"title":"Probabilistic edge detection in 3D optical microscopy images of tissue samples","authors":"Kaustav Nandy, Prabhakar R. Gudla, R. Chellappa, S. Lockett","doi":"10.1109/ISBI.2015.7164152","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7164152","url":null,"abstract":"Inspired by a state of the art 2D algorithm for edge detection in natural images, in this work we report the development of an accurate 3D probabilistic edge detector for fluorescence optical microscopy images of tissue samples. The method utilizes multi-orientation and multi-scale brightness, textural and spectral properties of the data to compute a probabilistic edge map. To demonstrate the strengths and accuracy of the proposed algorithm, comparisons of the edge maps produced by our algorithm and several other popular edge detectors on simulated and real 3D microscopic volumes are provided.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116675573","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Automated monitoring of human embryonic cells up to the 5-cell stage in time-lapse microscopy images 在延时显微镜图像中自动监测人类胚胎细胞至5细胞阶段
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-07-23 DOI: 10.1109/ISBI.2015.7163894
Aisha Khan, Stephen Gould, M. Salzmann
{"title":"Automated monitoring of human embryonic cells up to the 5-cell stage in time-lapse microscopy images","authors":"Aisha Khan, Stephen Gould, M. Salzmann","doi":"10.1109/ISBI.2015.7163894","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7163894","url":null,"abstract":"Measurement of the proliferative behavior of human embryonic cells in vitro is important to many biomedical applications ranging from basic biology research to advanced applications, such as determining embryo viability during in vitro fertilization (IVF) treatments. Automated prediction of the embryo viability, by tracking cell divisions up to the 4-cell stage, improves embryo selection and may lead to increased success rates in IVF pregnancies. Recent research in cell biology has suggested that tracking cell divisions beyond the 4-cell stage further improves embryo selection. In the current state-of-the-art, later events (e.g., time to reach the 5-cell stage) can only be assessed manually. In this work we automatically predict the number of cells at every time point, and predict when the embryo divides beyond four cells in a time-lapse microscopy sequence. Our approach employs a conditional random field (CRF) that compactly encodes various aspects of the evolving embryo and estimates the number of cells at each time step via exact inference. We demonstrate the effectiveness of our method on a data set of 33 developing human embryos.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124176707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Detection of genetic factors associated with multiple correlated imaging phenotypes by a sparse regression model 通过稀疏回归模型检测与多种相关成像表型相关的遗传因素
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-07-23 DOI: 10.1109/ISBI.2015.7164130
D. Lin, Jingyao Li, V. Calhoun, Yu-ping Wang
{"title":"Detection of genetic factors associated with multiple correlated imaging phenotypes by a sparse regression model","authors":"D. Lin, Jingyao Li, V. Calhoun, Yu-ping Wang","doi":"10.1109/ISBI.2015.7164130","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7164130","url":null,"abstract":"Recently, more evidence of polygenicity and pleiotropy has been found in genome-wide association (GWA) studies of complex psychiatric diseases (e.g., schizophrenia), where multiple interacting genetic variants may affect multiple phenotypic traits simultaneously. In this work, we propose a new sparse collaborative group-ridge low-rank regression model (sCGRLR) to study the pleiotropic effects of a group of genetic variants on multiple imaging-derived quantitative traits (i.e., endophenotype). In the method, we enforce sparse and low-rank regularizations to reduce the number of features and then construct an effective gene or gene-set based statistic test to evaluate the significance of selected features. We show the advantage of our method with other gene-set pleiotropy analysis methods and other sparse multivariate regression methods in terms of type I error and power on simulated data. Finally, we demonstrate its application to real data analysis on the study of schizophrenia.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133332333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Parallel and memory efficient multimodal image registration for radiotherapy using normalized gradient fields 基于归一化梯度场的并行多模态图像配准
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7163977
L. König, A. Derksen, M. Hallmann, N. Papenberg
{"title":"Parallel and memory efficient multimodal image registration for radiotherapy using normalized gradient fields","authors":"L. König, A. Derksen, M. Hallmann, N. Papenberg","doi":"10.1109/ISBI.2015.7163977","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7163977","url":null,"abstract":"We introduce a new highly parallel and memory efficient deformable image registration algorithm to handle challenging clinical applications. The algorithm is based on the normalized gradient fields (NGF) distance measure and Gauss-Newton numerical optimization. By carefully analyzing the mathematical structure of the problem, a matrix-free Hessian-vector multiplication for NGF is derived, giving a highly integrated formulation. Embedding the new scheme in a full, non-linear image registration algorithm enables fast calculations on high resolutions with dramatically reduced memory consumption. The new approach provides linear scalability compared with a traditional sparse-matrix-based scheme. The algorithm is evaluated on a challenging problem from radiotherapy, where pelvis cone-beam CT and planning CT images are registered. Speedups up to a factor of 149.3 for a single Hessian-vector multiplication and of 20.3 for a complete non-linear registration are achieved.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124365246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Evaluating the effect of bit rate on the quality of portable ultrasound video 评价比特率对便携式超声视频质量的影响
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7163860
M. Gray, Herman Morchel, V. Hazelwood
{"title":"Evaluating the effect of bit rate on the quality of portable ultrasound video","authors":"M. Gray, Herman Morchel, V. Hazelwood","doi":"10.1109/ISBI.2015.7163860","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7163860","url":null,"abstract":"This study analyzes the effect of bit rate on real time, wireless, and secure medical ultrasound video transmission quality. In order to achieve a thorough quality analysis, transmitted ultrasound video of varying bit rates was analyzed through both objective and subjective assessments. Objective assessment calculations of peak signal to noise ratio (PSNR) and structural similarity index (SSIM) indicate that as bit rate decreases, ultrasound video quality also decreases. For subjective assessments, ultrasound trained medical professionals evaluated the video and rated its quality using Mean Opinion Scores. The resulting data is used to develop a minimum bit rate threshold to ensure transmitted video is of adequate quality so that physicians may make an accurate diagnosis. A correlation is made and a minimum bit rate threshold of 1 Mbps is established. This bit rate threshold is the first quality standard for real time wirelessly transmitted ultrasound video, is needed to optimize quality and time delay, and can provide a reference bit rate for the transmission of other types of medical video.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125014759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Cross-modality medical image detection and segmentation by transfer learning of shapel priors 基于形状先验迁移学习的跨模态医学图像检测与分割
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7163902
Yefeng Zheng
{"title":"Cross-modality medical image detection and segmentation by transfer learning of shapel priors","authors":"Yefeng Zheng","doi":"10.1109/ISBI.2015.7163902","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7163902","url":null,"abstract":"Machine learning based methods have been widely used for detecting and segmenting various anatomical structures in different medical imaging modalities. The robustness of such approaches is largely determined by the number of training samples. In practice it is often difficult to acquire sufficient training samples for a certain imaging modality. Since multiple imaging modalities are often used for disease diagnosis or surgical planning, images of the same anatomical structure may be available in a different modality. In this work we investigate the effectiveness of shape priors learned from a different modality (e.g., CT) to improve the segmentation accuracy on the target modality (e.g., MRI). The shape priors are exploited in the marginal space learning framework in several ways, e.g., increasing the pose hypothesis set, enriching the statistical shape model, and synthesizing new training images with real shapes. Experiments show that the additional shape priors transferred from a different source can dramatically improve the segmentation accuracy when the training set is small (e.g., with 10 or 20 training images).","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125829269","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
A novel framework for automatic segmentation of kidney from DW-MRI 一种新的DW-MRI肾脏自动分割框架
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7164028
M. Shehata, F. Khalifa, A. Soliman, Rahaf Alrefai, M. El-Ghar, Amy C. Dwyer, R. Ouseph, A. El-Baz
{"title":"A novel framework for automatic segmentation of kidney from DW-MRI","authors":"M. Shehata, F. Khalifa, A. Soliman, Rahaf Alrefai, M. El-Ghar, Amy C. Dwyer, R. Ouseph, A. El-Baz","doi":"10.1109/ISBI.2015.7164028","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7164028","url":null,"abstract":"The segmentation of the kidney tissues is a key step in developing any non-invasive computer-aided diagnostic (CAD) system for early detection of acute renal transplant rejection. This paper introduces a geometric (level-set)-based deformable model approach for the 3D kidney segmentation from diffusion-weighted magnetic resonance imaging (DW-MRI). The proposed deformable model is guided by a stochastic speed relationship based on an adaptive shape prior guided by the visual appearance of the DW-MRI data. The voxel-wise guiding of the level-sets is obtained by integrating these three image features into a joint Markov-Gibbs random field (MGRF) model of the kidney and its background. The segmentation approach was evaluated for 40 DW-MRI data sets acquired at b-values ranging from 0 to 1000 s/mm2 and compared against other segmentation methods using three evaluation metrics: the Dice similarity coefficient (DSC), the 95-percentile modified Hausdorff distance, and the absolute kidney volume difference. Experimental results' evaluation between manually drawn and automatically segmented contours confirm the robustness and accuracy of the proposed approach.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125320142","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
A GMM-based feature extraction technique for the automated diagnosis of Retinopathy of Prematurity 基于gmm的早产儿视网膜病变特征提取技术
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7164161
V. Bolón-Canedo, E. Cansizoglu, Deniz Erdoğmuş, Jayashree Kalpathy-Cramer, M. Chiang
{"title":"A GMM-based feature extraction technique for the automated diagnosis of Retinopathy of Prematurity","authors":"V. Bolón-Canedo, E. Cansizoglu, Deniz Erdoğmuş, Jayashree Kalpathy-Cramer, M. Chiang","doi":"10.1109/ISBI.2015.7164161","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7164161","url":null,"abstract":"Retinopathy of Prematurity (ROP) is an ophthalmic disease that is a leading cause of childhood blindness throughout the world. Accurate diagnosis of ROP is vital to identify infants who require treatment, which can prevent blindness. Arterial tortuosity and venous dilation in the retina are important signs of ROP, so it is necessary to extract these features from points on the vessels or vessel segments. Then, an image is represented with statistics such as minimum, maximum or mean of these values. However, these statistics provide biased estimates as an image contains both healthy and abnormal vessels. In this work, we present a novel feature extraction technique that represents each image with the parameters of a two-component Gaussian Mixture Model (GMM). Using these features, we performed classification experiments on a manually segmented retinal image dataset consisting of 77 images. The results show that GMM-based features outperform other features that are based on classical statistics, with accuracy over 90%. Moreover, if the features are extracted from the whole image without distinguishing veins and arteries, proposed features provide better performance compared to using traditional statistics.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116012533","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Quasi-isometric length parameterization of cortical sulci: Application to handedness and the central sulcus morphology 皮质沟的准等距长度参数化:应用于手性和中央沟形态
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7164105
O. Coulon, J. Lefévre, S. Klöppel, H. Siebner, J. F. Mangin
{"title":"Quasi-isometric length parameterization of cortical sulci: Application to handedness and the central sulcus morphology","authors":"O. Coulon, J. Lefévre, S. Klöppel, H. Siebner, J. F. Mangin","doi":"10.1109/ISBI.2015.7164105","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7164105","url":null,"abstract":"We present in this paper a method to perform a length parameterization of cortical sulcus meshes. Such parameterization allows morphological features to be localized in a normalized way along the length of the sulcus and can be used to perform population studies and group comparisons. Our method uses the second eigenfunction of the Laplace-Beltrami operator, and the resulting parameterization is quasi-isometric. The process is validated on the central sulci of a set of subjects and its efficiency is demonstrated by quantifying morphological differences between left and right-handed subjects.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"148 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116573619","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
BM3D-based ultrasound image denoising via brushlet thresholding 基于bm3d的超声图像刷波阈值去噪
2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI) Pub Date : 2015-04-16 DOI: 10.1109/ISBI.2015.7163961
Yu Gan, E. Angelini, A. Laine, C. Hendon
{"title":"BM3D-based ultrasound image denoising via brushlet thresholding","authors":"Yu Gan, E. Angelini, A. Laine, C. Hendon","doi":"10.1109/ISBI.2015.7163961","DOIUrl":"https://doi.org/10.1109/ISBI.2015.7163961","url":null,"abstract":"In this paper, we present a brushlet-based block matching 3D (BM3D) method to collaboratively denoise ultrasound images. Through dividing image into multiple blocks, we group them based on similarity. Then, grouped blocks sharing similarity form a 3D image volume. For each volume, brushlet thresholding is applied to remove noise in the frequency domain. Upon completion of individual filtering, the volumes are aggregated and reconstructed globally. To evaluate our method, we run our denoising scheme on synthetic images corrupted with additive or multiplicative noise. The results show that our method can achieve good denoising performance in comparison with existing methods. Our method is also evaluated on cardiac and fetal ultrasound images. Analysis on the contrast and homogeneity of the denoised images demonstrates the feasibility of applying our method to ultrasound images to improve image quality and facilitate further processing such as segmentation.","PeriodicalId":389765,"journal":{"name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122354875","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书