1997 Rural Electric Power Conference (Cat. No.97CH36079)最新文献

筛选
英文 中文
T2 ACSR conductors: lessons learned T2 ACSR导体:经验教训
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595615
M. Vogt
{"title":"T2 ACSR conductors: lessons learned","authors":"M. Vogt","doi":"10.1109/REPCON.1997.595615","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595615","url":null,"abstract":"Central Iowa Power (CIPCO) has been rebuilding and upgrading approximately 30 miles of 34.5 kV lines each year since 1987. CIPCO's service territory has a rich history of damaging ice and wind storms. T2 ACSR conductors have been used on much of the construction in an effort to reduce or eliminate the damage. Many lessons have been learned about the use of T2 conductor, specifically in the areas of design, purchasing, associated hardware, installation, and long-term performance.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"107 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114091842","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Motion resistance bare overhead conductor development review 运动电阻裸架空导体发展回顾
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595620
E. Sanders
{"title":"Motion resistance bare overhead conductor development review","authors":"E. Sanders","doi":"10.1109/REPCON.1997.595620","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595620","url":null,"abstract":"This paper is a review of work and testing done in the development of a new design of bare overhead conductor to prevent or reduce galloping and aeolian vibration. The new conductor is a departure from the existing design of conductor used for prevention of galloping and aeolian vibration in that the new conductor is comprised of a single conductor not two as in the existing design.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"191 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121728450","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Designing harmonic filters for adjustable speed drives to comply with IEEE-519 harmonic limits 设计可调速驱动器的谐波滤波器,以符合IEEE-519谐波限值
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595593
M. McGranaghan, D. Mueller
{"title":"Designing harmonic filters for adjustable speed drives to comply with IEEE-519 harmonic limits","authors":"M. McGranaghan, D. Mueller","doi":"10.1109/REPCON.1997.595593","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595593","url":null,"abstract":"This paper discusses the application of the revised IEEE-519 Harmonics standards to typical industrial facilities employing adjustable speed drives (ASDs). The harmonic generation characteristics of ASDs are described, Requirements for control of the harmonic currents are developed as a function of the ASD characteristics, overall plant loading level, power system characteristics, and power factor correction requirements. Filter design procedures are presented for controlling the harmonic currents injected onto the power system.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128261317","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 94
The establishment of a mapping protocol utilizing GPS as a data collection source [for electric utilities] 利用GPS作为数据采集源的制图协议的建立[用于电力公用事业]
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595591
C. Smallwood
{"title":"The establishment of a mapping protocol utilizing GPS as a data collection source [for electric utilities]","authors":"C. Smallwood","doi":"10.1109/REPCON.1997.595591","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595591","url":null,"abstract":"Many means exist for setting up a mapping protocol for an electric utility. The overall purpose of this report is to explain the options available in setting up a mapping protocol including data collection, storage and accessing routines. As a result, this report describes collection routines such as GPS and current mapping technologies. After covering the possibilities of collection and mapping routines, the most efficient mapping protocol is established and then discussed for validation.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117270097","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A method of reporting distribution field inspection data 一种报告分布现场检查数据的方法
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595589
T.E. Nigon
{"title":"A method of reporting distribution field inspection data","authors":"T.E. Nigon","doi":"10.1109/REPCON.1997.595589","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595589","url":null,"abstract":"This paper describes the process of developing a method to report electric distribution field inspection data that is collected in various headquarters located in the NSP-Wisconsin service territory. The electric distribution inspection data include, field observations on equipment conditions, amp and voltage measurements taken from capacitors, recloser, and voltage regulators and other information taken by field personnel when inspecting distribution facilities. The electric distribution area covers approximately 20000 square miles in Western Wisconsin with a combination of urban and rural customers. The field inspection data is collected and entered in field or office computers. The data is stored in a central server and is available to all employees. Reports are created after the inspection data is collected The reports have information that can be used to improve the reliability and performance of the electric distribution. The benefits of this method of reporting information are that the data is available for all users, work that needs to be done is shown on the reports, and the information can be quickly reviewed using the computer instead of sorting through paper records. This paper shows how reports can be created using a database program and how the reports can be used to improve the electric distribution system.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130633022","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Improved lighting and ventilation systems for dairy facilities: its effects on herd health and milk production 改善乳品设施的照明和通风系统:对畜群健康和牛奶生产的影响
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595632
J. Martens
{"title":"Improved lighting and ventilation systems for dairy facilities: its effects on herd health and milk production","authors":"J. Martens","doi":"10.1109/REPCON.1997.595632","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595632","url":null,"abstract":"Otter Tail Power Company and Minnesota Power in a tailored collaboration with the Electric Power Research Institute (EPRI), the National Food and Energy Council, University of Minnesota, Minnesota Extension Service, Dr. John Chastain, Clemson University, and Dr. Jerry Beehler, DVM, Lake Region Veterinary Clinic, Elbow Lake Minnesota, have been involved in a project to work with several dairy customers on improving lighting and ventilation systems for livestock production facilities. Proper lighting and ventilation is very important because it can provide the proper environment for many tasks including, office work, cleaning milking equipment, treatment of animals, health of animals. Energy conservation is of utmost concern in both lighting and ventilation applications. A good working environment is needed to increase working efficiency, comfort, and safety. Amounts of light will vary depending on the tasks that are being performed in the various areas of the milking or housing facility.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125379137","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Distribution feeder reliability studies 配电馈线可靠性研究
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595602
W. Kersting, W. H. Phillips, R. C. Doyle
{"title":"Distribution feeder reliability studies","authors":"W. Kersting, W. H. Phillips, R. C. Doyle","doi":"10.1109/REPCON.1997.595602","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595602","url":null,"abstract":"As the power industry moves into a new competitive era, the reliability of radial distribution feeders becomes a primary issue in comparing the \"new\" versus the \"old\" way of serving customers. In order to make the comparison, a distribution engineer needs to have the analysis tools to perform the necessary reliability studies. For purposes of this paper the reliability studies are limited to the calculation of the annual \"outage rate\" and associated \"restoration time\" for a typical customer on a radial distribution feeder. The paper develops the background and theory for computing these reliability indices. The method can be applied to demonstrate how different devices and/or feeder configurations affect the average customer on a specific feeder. The equations are derived in such a manner as to facilitate their use in computational software packages.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129173113","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 40
A systematic approach to the replacement of an aging distribution system 更换老化配电系统的系统方法
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595590
D. Rudolph
{"title":"A systematic approach to the replacement of an aging distribution system","authors":"D. Rudolph","doi":"10.1109/REPCON.1997.595590","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595590","url":null,"abstract":"Cass County Electric Cooperative (CCEC), like many other electric cooperatives, owns, operates, and maintains an aging overhead and a prematurely failing underground primary distribution system. Overhead primary comprises 69% or 3178 circuit miles of CCEC's distribution system. The vast majority of CCEC's overhead primary distribution system was constructed during the 1930s and 1940s, which indicates the system is reaching 50+ years of age. Underground primary cable comprises the remaining 31% or 1436 circuit miles of CCEC's distribution system. Installation of underground primary cable was very prevalent in the 1960s and 1970s at CCEC. However, due to a continuing history of premature cable failures, underground primary cable is now being replaced significantly sooner than the cable's anticipated life expectancy. This paper outlines the systematic approach utilized by Cass County Electric Cooperative to begin replacing its aging overhead and prematurely failing underground primary distribution systems.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125939377","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Using series capacitors to mitigate voltage flicker problems 使用串联电容器减轻电压闪变问题
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595594
M. Marshall
{"title":"Using series capacitors to mitigate voltage flicker problems","authors":"M. Marshall","doi":"10.1109/REPCON.1997.595594","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595594","url":null,"abstract":"Since 1989, Union Electric has made use of series capacitor banks to mitigate voltage flicker problems on long distribution feeders with fluctuating loads. The types of loads being compensated for are cotton gins, a water well pump, sawmills, and a dog food processing plant, with the flicker typically being reduced by 60 to 80 percent. These series capacitors have been designed, constructed, and installed by Union Electric engineering and construction personnel at a cost comparable to a shunt bank installation.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132263370","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Using rainwear as switching jackets. A reasonable solution for electric arc exposure 使用雨衣作为交换夹克。合理解决电弧暴露问题
1997 Rural Electric Power Conference (Cat. No.97CH36079) Pub Date : 1997-04-20 DOI: 10.1109/REPCON.1997.595587
E. Hoagland
{"title":"Using rainwear as switching jackets. A reasonable solution for electric arc exposure","authors":"E. Hoagland","doi":"10.1109/REPCON.1997.595587","DOIUrl":"https://doi.org/10.1109/REPCON.1997.595587","url":null,"abstract":"LG&E has tested numerous types of clothing for worker protection under electric arc exposure situations and discusses the test methods used along with practical application of the ATPY (arc thermal protective value) and HAF (heat attenuation factor) results which are being reported by manufacturers of flame retardant (FR) clothing. This article focuses on the newly discovered and documented feasibility of using FR rainwear in high fault current switching applications. This article includes data and a comparison of 7 popular rainsuits materials in their performance under electrical arc conditions. Some of these rainsuits have been shown by mannequin testing to withstand arcs up to 30000 Amps 15 cycles without sustained fire or ignition of clothing covered. Using rainwear as switching jackets could allow \"double duty\" use of rainsuits in plants and on line trucks. Further Neoprene/Nomex(R) and some PYC/Nomex(R)/Kevlar(R) rainsuits have, in testing, proven more protective than woven Nomex(R) \"switching jackets\" costing substantially more.","PeriodicalId":384151,"journal":{"name":"1997 Rural Electric Power Conference (Cat. No.97CH36079)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124165214","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书