Kristin T. Fujita, Oliver M. Barry, Alejandro Torres, M. Crystal, Mariel E. Turner
{"title":"Simultaneous stent implantation for pulmonary artery bifurcation stenosis in infants.","authors":"Kristin T. Fujita, Oliver M. Barry, Alejandro Torres, M. Crystal, Mariel E. Turner","doi":"10.25270/jic/24.00097","DOIUrl":"https://doi.org/10.25270/jic/24.00097","url":null,"abstract":"OBJECTIVES\u0000Pulmonary artery (PA) bifurcation stenosis often requires simultaneous stent placement, which may be technically challenging. Limited data exist regarding this practice in infants. We aim to report the procedural outcomes and safety of bifurcation stent placement in infants.\u0000\u0000\u0000METHODS\u0000We performed a single-center retrospective review of infants younger than 12 months who underwent simultaneous stent placement for PA bifurcation stenosis from January 1, 2001 through December 31, 2019.\u0000\u0000\u0000RESULTS\u0000Seventeen infants underwent simultaneous PA bifurcation stent placement. The median age was 6.4 months (1.1-10.1 months), and weight was 5.8 kg (3-10.6 kg). Nine (52.9%) patients had had prior PA intervention. Most stents were placed in central PAs (28, 82.4%), followed by lobar branches (6, 17.6%). All patients received pre-mounted stents. The peak gradient across each branch decreased from 47.4 ± 16 to 18.7 ± 13 mm Hg (P less than .0001). The right ventricle to systemic systolic pressure ratio decreased from systemic (1.0 ± 0.3) to just over half systemic (0.58 ± 0.2) (P = .0001). The minimum vessel diameter increased from 3.6 ± 1.5 to 6.0 ± 1.9 mm (P less than .0001). There were 4 (23.5%) patients with high severity adverse events. There were no procedure-related deaths. The median follow-up period was 83.8 months (5.3 months-19.4 years). All patients had subsequent PA re-intervention at a median time of 8.1 months (2.9 months-8.8 years), and median time to re-operation was 19.1 months (2.9 months-7.5 years).\u0000\u0000\u0000CONCLUSIONS\u0000Simultaneous PA stent placement is an effective strategy for relief of bifurcation stenosis in infants. Future transcatheter interventions are necessary to account for patient growth, but may delay the need for re-operation.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"61 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140972478","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Geri Wong, Mark Tsz Kin, Leo Kar Lok Lai, K. Kam, Alex Pui-Wai Lee, Chin-Pang Chan, Joseph Yat-Sun Chan, Chak-yu So
{"title":"Early LAAO device migration after combined atrial fibrillation ablation and left atrial appendage occlusion.","authors":"Geri Wong, Mark Tsz Kin, Leo Kar Lok Lai, K. Kam, Alex Pui-Wai Lee, Chin-Pang Chan, Joseph Yat-Sun Chan, Chak-yu So","doi":"10.25270/jic/24.00104","DOIUrl":"https://doi.org/10.25270/jic/24.00104","url":null,"abstract":"The combined procedure of catheter ablation and percutaneous left atrial appendage occlusion for patients with atrial fibrillation has been shown to be safe and feasible using radiofrequency energy or cryoballoon.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"5 2","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140981835","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Unravelling supravalvular aortic stenosis in a young patient: look beyond the valve.","authors":"Abhinav Jain, S. Agstam, Abhinav Jain, Mayank Yadav, Sivasubramanian Ramakrishnan, Rakesh Yadav","doi":"10.25270/jic/24.00128","DOIUrl":"https://doi.org/10.25270/jic/24.00128","url":null,"abstract":"A 16-year-old adolescent girl was referred to our tertiary care center for management of a failed aortic valve balloon dilatation procedure for congenital valvular aortic stenosis. The medical records revealed a residual peak-to-peak gradient of 80 mm Hg after 2 dilations with 16 x 6-mm Tyshak balloon (NuMed Inc.).","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"19 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140979829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Valve-in-valve implantation to seal post-dilation-induced annular rupture in transcatheter aortic valve replacement.","authors":"Kun Wang, Yiming Qi, Wenzhi Pan","doi":"10.25270/jic/24.00092","DOIUrl":"https://doi.org/10.25270/jic/24.00092","url":null,"abstract":"An 85-year-old woman was admitted to our hospital with severe symptomatic aortic stenosis. Preoperative computed tomography and transesophageal echocardiography (TEE) revealed a type I bicuspid aortic valve.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"22 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140984330","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Impasse sign in balloon mitral valvotomy.","authors":"S. Agstam, Abhinav Jain, Rakesh Yadav","doi":"10.25270/jic/24.00105","DOIUrl":"https://doi.org/10.25270/jic/24.00105","url":null,"abstract":"A 33-year-old female presented to our out-patient department with worsening shortness of breath over the past 2 years.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"25 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140658769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Salido-Tahoces, Á. Sánchez-Recalde, C. Fernández-Golfín, J. Zamorano-Gómez
{"title":"Percutaneous closure of incomplete surgical left atrial appendage ligation: success begins with the decision to try.","authors":"L. Salido-Tahoces, Á. Sánchez-Recalde, C. Fernández-Golfín, J. Zamorano-Gómez","doi":"10.25270/jic/24.00084","DOIUrl":"https://doi.org/10.25270/jic/24.00084","url":null,"abstract":"The authors present a case of percutaneous closure of an incomplete surgical left atrial appendage (LAA) ligation with a new device LAmbre (Lifetech ScientificCo Ltd).","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"21 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140657833","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Aatish Rengan, S. Agstam, Mohsin Raj Mantoo, Sivasubramanian Ramakrishnan
{"title":"Ballerina foot in heart.","authors":"Aatish Rengan, S. Agstam, Mohsin Raj Mantoo, Sivasubramanian Ramakrishnan","doi":"10.25270/jic/24.00116","DOIUrl":"https://doi.org/10.25270/jic/24.00116","url":null,"abstract":"A 67-year-old woman with no known risk factors for coronary artery disease presented to the outpatient department with complaints of exertional fatigue and angina New York Heart Association class III.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"6 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140653853","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Basavanna Dinesha, Y. Shrimanth, Aditha Cibi, K. Sadananda, Snehal Jayarama, K. Ravindranath
{"title":"Wire entanglement to retrieve a dislodged stent from the proximal right coronary artery.","authors":"Basavanna Dinesha, Y. Shrimanth, Aditha Cibi, K. Sadananda, Snehal Jayarama, K. Ravindranath","doi":"10.25270/jic/24.00085","DOIUrl":"https://doi.org/10.25270/jic/24.00085","url":null,"abstract":"A 70-year-old woman who was a known diabetic and had hypertension presented with non-ST-elevation myocardial infarction. A coronary angiogram showed a significant lesion in the mid-portion of right coronary artery (RCA) followed by distal cut-off.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"165 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140731273","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Michaella Alexandrou, Athanasios Rempakos, Deniz Mutlu, Ahmed Al Ogaili, B. Rangan, Olga C Mastrodemos, Konstantinos Voudris, Anastasios Milkas, M. N. Burke, Yader Sandoval, Yiannis Chatzizisis, Konstantinos C. Siontis, E. Brilakis
{"title":"Interventional cardiologists' perspectives and knowledge towards artificial intelligence.","authors":"Michaella Alexandrou, Athanasios Rempakos, Deniz Mutlu, Ahmed Al Ogaili, B. Rangan, Olga C Mastrodemos, Konstantinos Voudris, Anastasios Milkas, M. N. Burke, Yader Sandoval, Yiannis Chatzizisis, Konstantinos C. Siontis, E. Brilakis","doi":"10.25270/jic/24.00052","DOIUrl":"https://doi.org/10.25270/jic/24.00052","url":null,"abstract":"BACKGROUND\u0000Artificial intelligence (AI) is increasingly utilized in interventional cardiology (IC) and holds the potential to revolutionize the field.\u0000\u0000\u0000METHODS\u0000We conducted a global, web-based, anonymous survey of IC fellows and attendings to assess the knowledge and perceptions of interventional cardiologists regarding AI use in IC.\u0000\u0000\u0000RESULTS\u0000A total of 521 interventional cardiologists participated in the survey. The median age range of participants was 36 to 45 years, most (51.5%) practice in the United States, and 7.5% were women. Most (84.7%) could explain well or somehow knew what AI is about, and 63.7% were optimistic/very optimistic about AI in IC. However, 73.5% believed that physicians know too little about AI to use it on patients and most (46.1%) agreed that training will be necessary. Only 22.1% were currently implementing AI in their personal clinical practice, while 60.6% estimated implementation of AI in their practice the next 5 years. Most agreed that AI will increase diagnostic efficiency, diagnostic accuracy, treatment selection, and healthcare expenditure, and decrease medical errors. The most tried AI-powered tools were image analysis (57.3%), ECG analysis (61.7%), and AI-powered algorithms (45.9%). Interventional cardiologists practicing in academic hospitals were more likely to have AI tools currently implemented in their clinical practice and to use them, women had a higher likelihood of expressing concerns regarding AI, and younger interventional cardiologists were more optimistic about AI integration in IC.\u0000\u0000\u0000CONCLUSIONS\u0000Our survey suggests a positive attitude of interventional cardiologists regarding AI implementation in the field of IC.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"192 S537","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140730758","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Corcione, P. Ferraro, F. Finizio, M. Cimmino, M. Albanese, G. Biondi‐Zoccai, P. Denti, A. Rubbio, A. Bartorelli, A. Mongiardo, Salvatore Giordano, F. De Felice, M. Adamo, Matteo Montorfano, Cesare Baldi, G. Tarantini, Francesco Giannini, Federico Ronco, I. Monteforte, E. Villa, Maurizio Ferrario, L. Fiocca, F. Castriota, A. Squeri, C. Tamburino, F. Bedogni, A. Giordano
{"title":"Transcatheter mitral valve repair with MitraClip: comparison of NT, NTr, and XTr Devices.","authors":"N. Corcione, P. Ferraro, F. Finizio, M. Cimmino, M. Albanese, G. Biondi‐Zoccai, P. Denti, A. Rubbio, A. Bartorelli, A. Mongiardo, Salvatore Giordano, F. De Felice, M. Adamo, Matteo Montorfano, Cesare Baldi, G. Tarantini, Francesco Giannini, Federico Ronco, I. Monteforte, E. Villa, Maurizio Ferrario, L. Fiocca, F. Castriota, A. Squeri, C. Tamburino, F. Bedogni, A. Giordano","doi":"10.25270/jic/24.00020","DOIUrl":"https://doi.org/10.25270/jic/24.00020","url":null,"abstract":"OBJECTIVES\u0000Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER.\u0000\u0000\u0000METHODS\u0000Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications.\u0000\u0000\u0000RESULTS\u0000A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05).\u0000\u0000\u0000CONCLUSIONS\u0000New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.","PeriodicalId":378289,"journal":{"name":"The Journal of invasive cardiology","volume":"175 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140730991","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}